Laserfiche WebLink
DEMOLITI4N SHEET NOTES: H n R G 1 S <br /> . . . I � I . . ( . �' � . � � � � . . . mechanicai <br /> ' I � � � I , electrical <br /> � � � �,��\ `-`- 1. EXISTING MECHANICAL ITEMS SHOWN AND NOTED ON PLAN WERE `e'e`°"'"'°""�"°"S <br /> 5e����ty <br /> i i ` � TAKEN FROM EXISTING DRAWINGS AND FIELD SURVEYS. e°e`gY <br /> � � \ � CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS 1201thirdavenue,suite600 <br /> � � <br /> seattle,washington 98101 <br /> i i PRIOR TO BID. REFERENCE ARCHITECTURAL DRAWINGS FOR t 206.445.3376 w hargis.hiz <br /> I __� _ _ _ _ _ _ _ }_ o — � — � - _ � ADDITIONAL SCOPE OF WORK AND INCLUDE WITHIN BID. <br /> — - - (E}HP ` N TO -___--�`L/ <br /> � `� (E)FTU-001 2. PROVIDE TEMPORARY SHORING AND BRACING AS REQUIRED FOR � B. C <br /> (ON ROOF) w <br /> SUPPORT DURING DEMOLITION AND CONSTRUCTION. ,� ,�. <br /> _ `1 � °� <br /> 3. ITEMS FOR REMOVAL ARE INDICATED TO ESTABLISH GENERAL �, <br /> f (E)20x14 � SCOPE OF DEMOLITION. CONTRACTOR SHALL VERIFY EXISTWG <br /> I <br /> �- � - - - - - - - 2 2 X 12"� CONDITIONS IN THE FIELD AND PROVIDE ADDITIONAL DEMOLITION <br /> L _ _ _ _ _ _ (E)FTU-001 330 AS NECESSARY TO COMPLETE AND COORDINATE THE WORK. REFER � � � <br /> i i 12„� TO MECHANICAL DEMOLITION SPECS FOR ADDITIONAL ��AL �� <br /> a � X 330 � � REQUIREMENTS. t2(��2�r6 <br /> (3-TYP) <br /> o�eri cp�nP���rE��cor� i � � Th e <br /> '��a N DEMOLITION NOTES: , , <br /> W � <br /> E 14x10 (E}18x12 ( 14x � rl f m 1 e r <br /> O I O D E M O L I S H A N D C A P DUCTWORK AS INDICATED. <br /> / . <br /> \ � � O2 SALVAGE (E) DIFFUSERS.TEMPORARILY REMOVE AND STORE (E)AIR Arc h 1 t e c t s � 1 •�• <br /> � , <br /> I DEVICES FOR REWSTALLATION ONCE CEILWG iS REINSTALLED. <br /> — - - r - - - - _��� .� _�.� _ . �� <br /> - — �- - - -- J <br /> '7983 Leary �Vay NE <br /> �_ _ _ _ _ Redmond, �A 98052 <br /> ' ' ' 425 881 - '�506 <br /> . � ) <br /> SHEET NOTES. <br /> mailC dr iftmier .com <br /> ���� � � 1. TEST, ADJUST, AND BALANCE ALL EXISTING DIFFUSERS, AND <br /> � � GRILLES TO CFM'S NOTED ON PLANS PER SECTION 230593. <br /> 1 MECHANICAL DEMOLITI�N PLAN 2. EXISTING EQUIPMENT LOCATIONS, DUCT SIZES, AND ROUTING <br /> N M� � SHOWN ARE FROM RECORD DRAWINGS. FIELD VERIFY EXACT SIZES, <br /> SCALE: 1/4" = 1'-0° <br /> CONFIGURATION, AND LOCATIONS. � � O <br /> � � � � � <br /> � rr--�,_ � � O� <br /> 3 FLAG NOTES: Z at <br /> \ HP-03 O � <br /> M9.1 <br /> , ON ROOF) �,,, <br /> i o � � � CONNECT FLEX DUCT TO REINSTALLED SUPPLY DIFFUSER. � „ <br /> — —a— �— __--- - — _ -- - — � �► <br /> — — - N— — — - O 1 �r,, <br /> N � � <br /> W � <br /> �-- r- — — — -� OPcRATIOP�15 .aFCU�I�Y �r , W <br /> � � v � <br /> \ 16x12 RA � � i U�FIC� � , <br /> (E)20x14 � 19�E�� , (� <br /> \ � - - - - - - - � � <br /> i X �z��� I i I � �i � <br /> `' L _ _ _ _ _ _ (E)FTU-001 350 - - - J � � <br /> 12"o X 12 s � 1 � � <br /> X 330 350 � Z � <br /> 3-TYP Q � <br /> ( ) a��rl co���ur���co�� � � V W <br /> � ' *� � 4 � <br /> 19�� N � O � <br /> ^ � �"., <br /> w <br /> v �E,�8X�2 0 � <br /> (E)14x10 � ..� <br /> 0 � <br /> T � <br /> ,,� HP-R A 70010 O Q � <br /> �� � <br /> � � \ � I� <br /> � 4 N <br /> 1 __ � <br /> -- - - — - - - —'_ � - r�LL�.._- �� <br /> - _ – f — � � � <br /> � � � <br /> �J . . . . �� \� <br /> � <br /> 2 MECHANICAL PLAN MECHANICAL <br /> N M1.1 SCALE: 1/4" = 1'-0�� FLOOR PLAN <br /> � I I ' --- — ---� <br /> i i <br /> i i i <br /> �. <br /> I <br /> � ' <br /> � <br /> � � � <br /> i <br /> (E) MECHANICAL � � �,� � � <br /> i EQUIPMENT i r (� <br /> —T , �� <br /> � �,�j `����� .__ . , <br /> � i (� � a� L����f �, <br /> � � ��:�. __.�� � ��.� o <br /> , � � �� - _ � ���- _ <br /> � �:�- w��� <br /> - - - - - - - - - - - - - -_-- - - - - - - - -- - - - - - - - - - -- - - - - - � _ _ - - - - - - , ��i� , �.� �� , <br /> � . I �� I�-*_'_-`- i_„� � i ,1� I � ` .�. �_ -�-- � . <br /> � � r � I �� �� � <br /> � � �_��f � , ,�.___�_�__ l ���� _ _�� <br /> ' (E) ROOF � I � � ���������������� � <br /> CURBS (TYP 4) � �----� �' --'_'_� �'_.; �'---,; � ,_.._. <br /> HP-03 I ! �l i <br /> � � � , <br /> � �— —I ( -1! ' � -1 � � `� ( - <br /> --�—�___�� ---�� i <br /> —� �� � I �� �� <br /> , �-- —� —' �� C � ��. ��—� <br /> � o �(E) ROOF j�� � � ' � ISSUE DATE: � 2 �2 1 6 <br /> � PENETRATIONS (TYP 7) —� <br /> --� � — --' — — � � o _� _ _--: — —�1 r. � - , � ..�� DRAWN BY: SF <br /> ��/ ���L{�—_���-� <br /> -- — - — -- ---� � `'�--� C H E C K E D e Y: B B C <br /> i ( !�.,:_� ^ <br /> � � � PROJECT NUMBER <br /> N KEY PLAN 21 6 <br /> �. <br /> 60 <br /> N 3 MECHANICAL ROOF PLAN sHEET NUMBER <br /> M1.1 SCALE: 1/8" = 1'-0" <br /> M1 . 1 <br />