Laserfiche WebLink
U N IT KEYED NOTES Architecture <br /> &Consulting <br /> Wz O DEMOLITION/ABATEMENT-UNIT: IF AND AS NEEDED, REMOVE DRYWALL AT WINDOW WRAP AREAS, DURING WINDOW <br /> PATIO OR DECK REPLACEMENT, TYP ALL UNITS. <br /> (R� 1OTyp � <br /> II UNIT A = = 14A PROVIDE (N)CONSTRUCTION O2 KITCHEN/BATHROOM COUNTERTOPS-UNITS: REPLACE KITCHEN COUNTERTOPS WITH PLASTIC LAMINATE TYPE. AT SELECT 2130 FOU RTH ST <br /> II STORAGE O PROVIDE (N)CONSTRUCTION NAIL FIN TYPE NAIL FIN TYPE SLIDING GLASS DOOR W/ UNITS, SEE OWNER'S SELECTIVE REPLACEMENT, MATRIX. <br /> DUAL PANE WINDOWS W/INSULATED Et LOW"E"GLASS,TYP ALL DUAL PANE INSULATED SAN RAFAEL, CA 94901 <br /> II O3 KITCHEN/BATHROOM CABINETS-UNITS: REPLACE DOORS AND DRAWERS WHERE DAMAGED. MINOR REPAIRS AND NEEDED. <br /> II (R� REPLACE IN CONJUNCTION W/SIDING REPLACEMENT LOW"E"GLASS,TYP ALL MATCH EXISTING. REPLACE CABINETS AT SELECT UNITS, SEE OWNER'S SELECTIVE REPLACEMENT,MaTR�x. PHON E (415) 457-6035 <br /> I� O DISHWASHERS-UNITS: REPLACE DISHWASHERS AT SELECTED UNITS, ENERGY STAR LABELED. <br /> II BEDROOM wz P.O. BOX 150539 <br /> II O5 REFRIGERATORS-UNITS: REPLACE REFRIGERATORS AT SELECTED UNITS, ENERGY STAR LABELED. SAN RAFAEL, CA 94915 <br /> II �R� O�,P PATIO OR DECK O RANGES-UNITS: REPLACE RANGES AT SELECTED UNITS. <br /> II UNIT D � <br /> 14A 7 TUB/SHOWERS-UNITS: SELECTIVE REPLACEMENTS REFINISH. TUB/SHOWER WITH MIRACLE METHOD OR SIMILAR CHEMICALLY <br /> 1 2A O BONDED MATERIAL AT SELECTIVE UNITS. 5EE OWNER'S SELECTIVE REPLACEMENT,MATRIX. <br /> 13A <br /> H�{W �R� O8 BATHROOM ACCESSORIES-UNITS: PROVIDE NEW TOWE�BARS, MIRRORS, MEDICINE CABINET AND DISPENSER, TYP ALL UNITS. <br /> LIVING � <br /> ROOM O9 NOT USED <br /> CHARLES PICK, ARCHITECT <br /> �� BEDROOM 10 NOT USED <br /> II O11 PAINT/DRYWALL-UNITS: MINOR REPAIRS AND TOUCH-UPS AS NEEDED. PAINT KITCHENS AND BATHROOMS, TYP ALL UNITS. <br /> ANY (N) DRYWALL MUST BE MOISTURE AND MOLD RESISTANT AT BATHROOM WALLS AND CEILING, CONFORM WITH <br /> �� ASTM#D3273 ���� <br /> �� 13A ���''a����R�(�. <br /> Wz �R, BEDROOM MECHA I �`����T���f� <br /> LIVING N CAL/ ELECTRICAL KEYED NOTES G�� ,� ; � <br /> W/D ROOM �H�:E��.� I �C` l <br /> 3A 1A SEISMIC STRAPPING: PROVIDE CODE CONFORMING SEISMIC RESTRAINTS,TYP ALL UNITS. �TAT� �� �'�'�a}-1�1�'TC�['� <br /> _ _ _ _ = LINEN 1 <br /> �I 2A HOT WATER HEATERS - UNITS: REPLACE ELECTRIC WATER HEATERS WITH HIGH EFFICIENCY TYPE. PROVIDE DRIP <br /> I) PANS, BLOW OFF VALVES AND RELATED PLUMBING IF AS NEEDED (SELECTED UNITS)SEE PLUMBING DRAWINGS. SEE EXPIRATION DATE:6/18/2017 <br /> OWNER'S SELECTIVE REPLACEMENT,MATRIX. <br /> 11 8 <br /> 3A LAUNDRY-UNITS: CHECK AND MAINTAIN ALL VENT CONNECTIONS, TYP ALL UNITS. <br /> _ _ _ _ _ = BATH <br /> DINING o O7 10A Z 4A NOT USED <br /> a <br /> � 6A - - 5q PLUMBING FIXTURES-UNITS: REPLACE ALL. SEE PLUMBING DRAWINGS. <br /> + + 6A PLUMBING TOILETS-UNITS: REPLACE ALL. SEE PLUMBING DRAWINGS. LEGEND <br /> � BATHROOM VANITIES-UNITS: PROVIDE TOP SET VANITY LAVATORIES TYP ALL UNITS. <br /> W/D �- I- o -z 3 14A �A � � (N) DIRECTIONAL SIGNAGE <br /> 11 2 3 7A 2 3 I _ 5A gq KITCHEN SINKS-UNITS: REPLACE STAINLESS STEEL KITCHEN SINK AND FAUCET. WHERE COUNTERTOPS ARE REPLACED. <br /> FAUCET NTE 1.5 GPM FLOW RATE, 5EE PLUMBING DRAWINGS. X PATH OF TRAVEL <br /> BEDROOM gqTH 5A I OO I 3A OO <br /> Z z 9A ELECTRIC BASEBOARD HEATERS-UNITS: REPLACE DAMAGED BASEBOARD ELECTRIC HEATERS (SELECTED UNITS). <br /> O O SEE ELECTRICAL DRAWINGS. ': (N) CONCRETE ANTICIPATED, <br /> 8A 11 I STORAGE KITCHEN �� DINING .. .. . ., ` VERIFYINFIELD <br /> a 6A KITCHEN r.�.4<�:.'1:;-:,a'..`.: . <br /> 10A �o � 10 BATHROOM VENTILATION-UNITS: REPLACE BATHROOM FANS WITH NEW CONSTANT RUNNING ENERGY STAR LABELED ;:�; ;:�, ;:�; ;: <br /> O6 � FIXTURE PER MECHANICAL AND ELECTRICAL DRAWINGS. RADIANT DAMPER FOR 1 HOUR FLOOR TO CEILING � ,.% ,,� , (N) GRADING, AC PAVING <br /> % '; � '; � '; % OR LANDSCAPE <br /> ,. . ,. . ,. .. . <br /> O + I I O � I1 A 14A 1A O O - - �.� — LOCATIONS, TYP ALL UNITS. , , , , <br /> (�� O � 5 � <br /> R + � R �O zA WH ��j,��1 � 11A KITCHEN VENTILATION-UNITS: REPLACE RANGE HOOD FANS, RECIRCULATING TYPE,TYP ALL UNITS. (E) WALL TO REMAIN <br /> �-x.J �R� 1 <br /> 12A LIGHTING INTERIOR-UNITS: SEE ELECTRICAL DRAWINGS. (E)WALL TO BE REMOVED <br /> W2 W1 y,�z — — <br /> 13A CATV-UNITS: PROVIDE NEW WIRING RUNS AND INTERIOR CONNECTS,TYP ALL UNITS. <br /> 14A LIGHTING EXTERIOR-UNITS: REPLACE ALL EXTERIOR DECK AND ENTRY LIGHT FIXTURES WITH LED TYPE. SEE ������1�/� (N) INTERIOR PARTITION <br /> ELECTRICAL DRAWINGS. <br /> UNIT TYPE '4' - 3 BED/ 1 BATH UNIT TYP 'I' - 1 BED/ 1 BATH (N) 1HOURRATEDWALL <br /> SCALE: 1/4"= 1'-0" SCALE: 1 l4"= 1'-0" <br /> 2 Z <br /> DRAWING REVISION LOG <br /> PERMIT SUBMITTAL 2/1/2017 <br /> �1 OWNER REVISION 3/15/2017 <br /> W2 W2 W2 <br /> O <br /> O <br /> �2 PLAN CHECK 1 3/28/2017 <br /> �R� � TYP PATIO PATIO OR DECK PATIO <br /> UNIT C O UNIT B �R� OTYP �R� 1 TYP <br /> �� 14A �� 14A UNIT TYPE B1 O 14A <br /> STORAGE II O 1 STORAGE � STORAGE II O <br /> �� <br /> 1 �� <br /> O O � <br /> O <br /> (R) R <br /> � ) R <br /> � � <br /> 2 <br /> BEDROOM NOTE: ALTERATIONS SHALL NOT <br /> BEDROOM BEDROOM <br /> REDUCE OR HAVE THE EFFECT OF <br /> REDUCING THE ACCESSIBILITY PER <br /> IEBC <br /> 13A 13A <br /> LIVING LIVING 13A LIVING PROJECT NAME: <br /> ROOM ROOM ROOM <br /> 2 - - - - - - - <br /> , , AVAI RE <br /> U N IT TYPE 3 ADD ITI ONAL SCOPE &t KEYED NOTES = _ _ _ _ — _ _ _ _ = APARTMENTs <br /> �2 DEMO WALL FOR(N) PREHUNG DOOR AND FRAME, (N)4X4 POSTS AND HEADER. 11 S �� g �� O <br /> 13 REMOVE WASHING AND DRYING EQUIPMENT, INCLUDING ASSOCIATED WATER HEATER. BATH BATH BATH R E N O V A T I O N <br /> 10A <br /> O 10A Z �7 10A 2 O 2 3 <br /> 14 REMOVE EXTERIOR DOOR AND JAMB. INFILL AND INSULATE WALL CAVITY, SIDE IN CONJUNCTION WITH EXTERIOR <br /> IMPROVEMENT WORK. 6q �q <br /> 5 6A �5 6A <br /> 1 5 R E M O V E E X I S T I N G F L O O R F I N I S H E S A N D R E P L A C E TO MATCH RESIDENTIAL CARPET SPECIFICATION. <br /> � � 5 <br /> 16 HANG (N) SHELF AND POLE IN (E)MECHANICAL CLOSET FOR(N)WALK-IN CLOSET. �q 1A 1A <br /> O�� INSTALL (N)WINDOW. LOWER SILL HEIGHT TO MATCH TYPICAL BEDROOM WINDOW SIZE, 4"x4". SEE WINDOW — WH W/D 3A II zA HW W/D 3A II Zq WH W/D 3A PROJECT LOCATION: <br /> SCHEDULE. 16 �� CLOSET II <br /> CLOSET <br /> I � DINING z II � DINING o II � DINING o <br /> NOTE: NO CHANGES TO (E) FIRE RATED CONSTRUCTION. I H 1 II a II a a 824 W CAS I N 0 ROAD <br /> 15 W / 12 vF-, �� � �� �� N <br /> � EVERETT, WA 95204 <br /> � �r-- � <br /> i w ii W ii w i <br /> l_ — L - -1 — 2 3 I 2 3 I 2 3 I <br /> 15 5AI O5 I 5AI O5 � 5A� OI <br /> NOTE: 13 (N) DOOR gq �� i O BEDROOM 8A �� � O2 BEDROOM $A �� � O SHEET TITLE: <br /> DEMOLITION SHOWN DASHED KITCHEN KITCHEN � KITCHEN � <br /> �- �. � lo I �o � �o � 2 <br /> � � O (N) OR(E)ADA LEVER UNIT PLANS - 1 BR, <br /> 2x4 FURR OUT AT INTERIOR WITH eMTYPEOX' I \\ � D � D �� D � I � O 6 O I��A 14A � O 6 �� q �4A I �4 6 I 11A 14A <br /> DRYWALL,AUGMENT R19 INSULATION TO R21 +R4 14 \ I I I I I I I O I � O O I I HARDWARE AT ENTRY <br /> L -�� _ J! _ J R O DOOR 2 BR AND 3 BR <br /> INSULATION AT ENTIRE WALL — — — — — — — — — — — - R R R R <br /> 2 W2 W1 <br /> W2 W1 W2 W1 <br /> UNIT TYPE '3' - CONVERT 1 BED/ 1 BATH �t LAUNDRY � � � � <br /> UNIT TYPE 2 2 BED/ 1 BATH UNIT TYP 2A - 2 BED/ 1 BATH <br /> SCALE: 1/4"= 1'-0" 2 TO 2 6 R/ 1 BA • <br /> SCALE: 1/4" = 1'-0" 2 SCALE: 1/4"= 1'-0" 2 <br /> Copyri�ht 2017 by Charles Pick, Architect and Basis Architecture &t Consultin� Inc. <br />