|
i : .____ _ _ __ _
<br /> I _ ` ' c� �n�
<br /> �`�-, r.�
<br /> , ,� ;,
<br /> ,:.
<br /> �
<br /> �
<br /> �� ,
<br /> �� ;
<br /> � ' r��
<br /> �
<br /> FTUNAV UNIT S�HEDULE ' ��
<br /> �
<br /> � HEATWG COIL FAN MOTOR �� � �
<br /> I MARK LOCATIC)N AREA SERVED MANUFACTURER/MODEL NO. CFM CFM INLET OUT!_ET INLET OUT MBH GPM EWT LWT WATER HP V/f1� FLA WEIGHT RUNOU'T VALVE DIMENSIONS SEQUENCE NOTES MARK z�� F��'` ����' ' r�� ti`�`'=
<br /> � � � � � � �- ,l?��r:�I�i, �iJA `;82_(i1
<br /> MAX MIN DUCT DUCT SP SP PD SIZE TYPE (LxWxH) OF
<br /> r���CJi'���: ��i'�'..ri!7.ut1�7
<br /> , (CFM} (CFM) (IN) (IN) (IN} (IN) (°F) (°F) ';(FT) (LBS) (IN) (INxINxIN) OPERATIONS ���.%:: ��=>.:�� 1 �t'��� '
<br /> FTU-013 COORIDUR 169 TELECOM 181/ LAB 182 NAILOR 35SWST-5 1115 446 12" PER PLAN 0.8 0.5 27.23 2.7 125 105 1.5 FT 1/5 277/1 5.8 250 3/4" 2-WAY 41x26x18 1/M10.4 1, 2, 4 FTU-013
<br /> � � � � � � � S ,
<br /> FTU-014 TEL.ECOM 183 TELECOM 183 NAILOR 35SWST-5 1485 594 14" PER PLAN 0.8 0.5 36.26 3.6 125 105 1.5 FT 1/3 277/1 5.8 250 1" 2-WAY 41x26x18 1/M10.4 1, 2, 4 FTU-014
<br /> ' Hargis Engineers, Inc.
<br /> FTU-015 �ELECOM 183 OFFICE 183A NAILOR 35SWST-1 225 90 6" PER PLAN 0.8 0.5 5.49 0.5 125 105 1.5 FT 1/20 277/1 3.1 250 314" 2-WAY 36x18x14 1/M10.4 1, 2, 4 FTU-015 1201 Third Avenue,Suite 604
<br /> ' Seattle,WA 98101
<br /> - FTU-016 OPEN OFFICE 180 OPEN OFFICE 180 NAILOR 35SWST-3 675 270 10° PER PLAN 0.8 0.5 16.48 1.6 125 105 1.5 FT 1i8 277/1 3.1 250 3/4" 2-WAY 36x18x18 1/M10.4 1, 2 FTU-016 t� 206.448.3376
<br /> f� 206.448.4450
<br /> FTU-Q17 OPEN OFFICE 180 OPEN OFFICE 180 NAILOR 35SWST-5 900 360 12° PER PLAN 0.8 0.5 21.98 2.2 125 105 1.5 FT 1/6 277/1 5.8 250 3/4" 2-WAY 41x26x18 1/M10.4 1, 2 FTU-017 w � hargis.biz �
<br /> �; .
<br /> � FTU-018 OPEN OFFICE 180 OPEN OFFICE 180 NAILOR 35SWST-3 675 270 10° PER PLAN 0.8 0.5 16.48 1.6 125 105 1.5 FT 1/8 277/1 3.1 250 3/4" 2-WAY 36x18x18 1/M10.4 1, 2, 4 FTU-018
<br /> „ „ � B, C�
<br /> � ���
<br /> FTU-019 OPEN OFFICE 180 OPEN OFFICE 180 NAILOR 35SWST-3 675 270 10 PER PLAN 0.8 0.5 16.48 1.6 125 105 1.5 FT 1/8 277/1 3.1 250 , 3/4 2-WAY 36x18x18 '1/M10.4 1, 2, 4 FTU-019 �'�'"4" �,
<br /> . � '
<br /> ,
<br /> • FTU-020 OPEN OFFICE 180 OFFICE 180A NAILOR 35SWST-1 280 112 6" PER PLAN 0.8 0.5 6.84 0.7 125 105 1.5 FT 1/20 277/1 3.1 250 3!4" 2-WAY 36x18x14 1/M10.4 1, 2, 4 , FTU-020
<br /> FTU-021 OPEN OFFICE 180 OFFICE 180B NAILOR 35SWST-3 425 170 8° PER PLAN 0.8 0.5 10.38 1.0 125 105 1.5 FT 1/15 277/1 3.1 250 3/4" 3-WAY 36x18x18 1/M10.4 1, 2, 4 FTU-021 �7� ,�
<br /> �
<br /> ��`�'�ivAl,
<br /> B
<br /> ' �(i���.f�
<br /> FTU-022 OPEN OFFICE 180 CONFERENCE 190 NRILOR 35SWST-1 270 108 ' 6" PER PLAN 0.8 0.� 6.59 G.7 125 ' 105 1.5 FT 1/20 277/1 3.1 250 3!4" 2-WAY 36x18x14 1/M10.4 1, 2, 4 FTU-022
<br /> FTU-023 OPEN OFFICE 180 CONFERENCE 189 NAILOR 35SWST-1 270 108 6" PER PLAN 0.8 0.5 6.59 0.7 125 105 1.5 FT 1/20 277/1 3.1 250 3/4° 2-WAY 36x18x14 1/M10.4 1, 2, 4 FTU-023 Q
<br /> �
<br /> FTU-024 WAITING 188 169/'187/188 NAILOR 35SWST-1 225 90 6" PER PLAN 0.8 0.5 5.49 > 0.5 125 105 1.5 FT 1/2G 277/1 3.1 250 3/4" 2-WAY 36x18x14 1/M10.4 1, 2, 4 FTU-024 � �
<br /> � z �p W
<br /> FTU-025 OA1-CENTRAL 168 OA1-168 NAILOR 35SWST-5 1250 500 12" PER PLAN 0.8 0.5 30.53 3.1 125 105 1.5 FT 1/4 277/1 5.8 250 1° 2-WAY 41x26x18 1/M10.4 1, 2, 4 FTU-025 p � �
<br /> i � U7 �
<br /> (n J f-'
<br /> FTU-026 OA�-CENTRAL 167 OA1-167 NAILOR 35SWST-5 1360 544 12" PER PLAN 0.8 0.5 33.21 3.3 �Y 125 105 1.5 FT 1/3 277/1 5.8 250 1" 2-WAY 41x26x18 1lM10.4 1, 2, 4 FTU-026 j z �
<br /> � I C� L.~L d
<br /> FTU-027 TELECOME SHOP 165 TELECOME SHOP 165 Nt�ILOR 35SWST-S 1565 626 14" PER PLAN 0.8 0.5 38.22 3.8 125 105 1.5 FT 1/3 277/1 5.8 250 1" 2-WAY 41x26x18 1/M10.4 1, 2, 4 FTU-027
<br /> ° FTU-028 CORRIDOR 169 TELECOM 181A NAILOR 35SWST-3 415 378 8" PER PLAN 0.8 0.5 13.17 1.3 125 105 1.5 FT 1/15 277/1 3.1 250 3/4" 2-WAY 36x18x18 1/M10.4 1, 2, 4 FTU-028 � �
<br /> w � �
<br /> H � �
<br /> _ Q oo �
<br /> � d�- �i
<br /> ' VAV-�115 KITCHEN 187 HEARING TEST 186 NAILOR 3001-4 120 48 4" PER PLAN 0.8 0.5 3.96 � 0.4 125 105 1.5 FT - - - 40 3/4" 2-WAY 21x10x10 2/M10.4 Z, 3 VAV-115 p
<br /> � z
<br /> 11930 29.5 ,
<br /> ;
<br /> , NOTES:
<br /> �
<br /> � 1. COORDINATE 12QV OR 277V POWER CONNECTIONS W/ DIVISION 26.
<br /> . } 2• EQUIPMENT SHALL BE PROVIDED WITH A VISIBLE NAMEPLATE INDICATING THE SHORT CIRCUIT CURRENT RATING (SCCR) IN ACCORDANCE WITH UL REQUIREMENTS. REFER TO ELECTRICAL DRAWINGS FOR MINI,MUM RATINGS. . (�
<br /> - 3. DIVISION 23 SHALL PROVIDE LOW VOLTAGE POWER SUPPLY TO UNIT. DO NOT PROVIDE DIV. 26 LINE VOLTAGE POWER. ' � I-► � .��,
<br /> 4. PROVIDE INTERFACE WITH OCCUPANCY. PROVIDED BY DIVISION 26. �J l /� ,
<br /> . . z z V 1
<br /> ' HW �
<br /> � � � Q
<br /> �, FAN SCHEDULE , � a � � W � �,
<br /> MARK I.00ATION AREA SERVED ANUFACTURER/MODEL NO FAN TYPE AIRFLOW ESP FAN MOTOR ; SPEED BACKDRAFT PHYSICAL MOUNTING/ DETAIL/ INTERLOCK INTERLOCK CONTROL NOTES MARK � Z � � �
<br /> CFM lIN WG DRIVE RPM HP/ V/Q1 CONTROL DAMPTER AT SUPPORT DIAGRAM DIV 23 DIV 26 DIAGRAM / � 1-
<br /> t ) . ) � LxWxH WEIGHT � � I- �
<br /> ` WATTS FAN (�NxINxIN) (LBS) EFERENC SEQUENCE ' � o � � r ^
<br /> il r � V J
<br /> n u
<br /> �
<br /> C
<br /> 0
<br /> .9 J
<br /> EF-14 ROOF KITCHEN 187 GREENHECK/G-097-VG DOWNBLAST 200 0.4 DIRECT 1317 1/4 120/1 ECM N 22 x16 20 ROOF 1/M9.4 Y N 2/P��10.2 1, 2 EF-14 0 � Z � � W
<br /> EF-15 ROOF LAB 182 GREENHECK 1 G-097-VG DOWNBLAST 200 0.4 DIRECT 1317 1/4 120/1 ECM N 22"°x16" 20 ROOF 1/M9.4 Y N 1/M10.2 1, 2 EF-15 y °! O ~ � �
<br /> : � � H L,t') W '
<br /> � ~ � "
<br /> � � ^' �
<br /> �.�...�
<br /> l V
<br /> NOTES: U�
<br /> 1. PROVIDE WITH MOTORIZED DAMPER, BIRDSCREEN, HINGED BASE, ROOF CURB, AND ECM MUTOR WITH MANUAL DIAL ADJUSTMENT FOR BALANCWG. � � Q O :
<br /> 2. EQUIPMENT SHALL BE PROVIDED WITH A VISIBLE NAMEPLATE INDICATING THE SHORT CIRCUIT CURRENT RATING (SCCR} IN ACCORDANCE WITH UL r�EQUIREMENTS. REFER TO ELECTRICAL DRAWINGS FOR MINIMUM RATINGS. Q = �
<br /> �.. � `
<br /> = ROQFTOP AIR HANDLlNG U(VIT SCHEDULE
<br /> SUPPLY FAN� RETURN/ RELIEF FAN ELEC HEATING COIL I COOLING COIL SEQUENCE
<br /> - AREA MAKE/ COIL MOTOR ESP MUTOR ESP V/Qf MCA MOCP HEATING EAT LAT HC MAX MAX EWT LWT BRANCH i SENS. TOTAL EAT EAT LAT CC MAX MAX EWT LWT BRANCH DIMEN OF SHEET TITLE:
<br /> MARK . SERVED LOCATION MODEL CFM OSA HP (IN) RPM CFM HP (�N) ;RPM (A) (A} (MBH) (F) (F) APD-(IN) WPD (FT) GPM HWSJR (IN) (MBH) (MBH) �B Wg (F) AFD (IN) WPD (FT} GPM CWS/R (IN) (LxWxH) WEIGHT OP�RATIONS NOTEs MECHANICAL ,
<br /> " EQUIPTMENT SCHEDULES ;
<br /> � AHU-�A4 OFFICE & TELE. ROOF SILENT AIRE/CUSTOM 12,625 1,575 '` (2)10 1.70 3,310 12,625 (2)5 0.90 1,175 480/3 46.3 50 109.2 62.1 70.0 0.15 2.5 125 'i05 10.9 1-1/4" i 296.8 349.2 76.4 63.0 55 0.40 5.0 42 56 49.9 2-1/2" 238x108x96 9,500 1/M10.3 1-9
<br /> I NOTES:
<br /> I 1. PROVIDE WITH SINGLE POINT ELECTRICAL CONNECTION. '
<br /> � 2. PROVIDE WITH 14" MINIMUM TALL ROOF CURB.
<br /> 3. PROVIDE WITH 100%o ECONOMIZER CAPABILITY.
<br /> 4. PROVIDE WITH RECESSED LOCATION FOR SUPPLY FAN AND RETURN FAN VFD'S. SIZE FOR LARGEST SPECIFIED VFD. DATE: O�-�OH�� 6',
<br /> 5. PROVIDE W/2" PRE-FILTER& 6" FINAL FILTER. PROVIDE SPACE FOR 12" FINAL FILTER. ALL FILTER SIZES SHALL BE STANDARD 24x12 OR 24x24 SIZE. ; )OB IVO.: � �{-OOH
<br /> 6. REFER TO UNIT DETAIL 5/M9.4 FOR ADDITIONAL INFORMATION.
<br /> 7. PROVIDE WITH VFD'S FOR SUPPLY RND RETURN FANS. TOTAL OF TWO VFD'S FOR AHU. r ', ~-�
<br /> ONE INCH AT FULL SCALE,
<br /> � $• EQUIPMENT SHA�L BE PROVIDED WITH A VISIBLE NAMEPLATE INDICATING THE SHORT CIRCUIT CURRENT RATING (SCCR) IN ACCORDANCE WITH UL REQUIREMENTS. REFER TO ELECTRICAL DRAWINGS FOR MINIMUM RATINGS. IF NOT, SCALE ACCORDINGLY '
<br /> :9. PROVIDE WITH DX HEAT PUMP COIL SECTION WITH MATCHING CAPACITIES TO HEAT PUMP CONDENSING UNIT SCHEDULE (CU-08) ON SHEET M0.3. SHEET:
<br /> +
<br /> I
<br /> ■
<br /> - SHEET 36 OF 95
<br />
|