Laserfiche WebLink
____ . _ s ; � � � <br /> _ __ _ <br /> . Light Fixture Control Listing �' a� <br /> = ROOM NUMBER ROOM NAME CONTROLLER SWITCH OS DAYLIGHT SENSOR HVAC/TIME CLOCK RELAY ` <br /> EMERGENCY RELAY PARTITION RELAY PARTITION SENSOR AUTOMATIC CONTROL NO�ES IY�ANUAL CONTROL NOTES � DETAIL � <br /> � <br /> u 163 R.F. EQUIP. LMRG101 LMSW-101 LMDG100 NA NA NA NA � NA NA ON/OFF VACANCY SENSOR ZONE. SPACE CONTROLLED VIA ON/OFF 3/E8.1 �� <br /> � • SWITCHING - <br /> � <br /> . � <br /> 164 STOR. LMRG101 LMDW-100 LMDW-100 NA NA NA NA NA NA ON/OFF VACANCY SENSOR ZONE. SPACE CONTROLLED VIA ON/OFF 3/E8.1 '�,, <br /> � SWITCHING � � � <br /> � <br /> ONjOFF VACANCY �ENSOR ZONE. SPACE CONTROLLED VIA ON/OFF <br /> 165 TELECOM SHOP LMRG101 LMS'�i-101 LMDG100 NA LMIO-1Q1 � EL�U-200 NA NA OCCUPANCY STATUS OUTPUTTO BMS SYSTEIVi. 3/E8.1 2a�:� �;oc�=F�;_�Fr� ,av� <br /> - SWITCHING. ' <br /> �v�r��.r r, +r�a ��2c�� <br /> ENTERTAINMENT DIMMWG VACANCY SENSOR ZUNE. FIXTURES CONTROLLED AS A SINGLE �;-�o`�': '1�,.,�?.�r��% <br /> 167 OA1- CENTRAL CONFERENC ROOM LMRG212 LMPS-104 LMDG100 NA LMIO-101 ELCU-200 LMIO-102 OCCUPANCY STATUS OUTPUT TO BMS SYSTEM. ROOM WHEN PARTITION IS QPEN AND SEPARATELY WHEN PARTITION IS 2/E8.1 �`;�� �"�'j� '���T�� <br /> �'S NETWORKS IRPS <br /> CLOSED. <br /> ENTERTAINMENT DIMMING VACA.NCY SENSOR ZONE. FIXTURES CONTROLLED AS A SINGLE H A R � I S <br /> 168 OA1- CENTRAL CONFERENC ROOM LMRG212 LMPS-104 LMDG100 NA LMIO-101 ELCU-200 LMIO-102 O C C U P A N C Y S T A T U S O U T P U T T O B M S S Y S T E M. R O O M W H E N P A R T I T I O N I S O P E N A N D S E P A R A T E L Y W H E N P A R T I T I O N I S 2/E 8.1 <br /> NETWORKS IRPS <br /> CLOSED. Hargis Engineers, Inc. <br /> 1201 Third Avenue,Suite 6{IO <br /> 169B ALCOVE NA NA NA NA NA NA NA NA NA CONNECT TO EXISTING CONTROLS IN CORRIDOR 169. N/A Seaitle,WA98101 <br /> . . ` � t�,2Q6.448.3376 <br /> CONTINUOUS 0-10V DIMMING. PRIMARY AND I f� 206.448.445fl <br /> � SECONDARY DAYLIGHTING ZONE. DAYLIGHT � w� hargis.biz <br /> � 180 (a) ' <br /> OPEN OFFICE LMRG213 LMDM-101 NA LMLS-500 °��MIO-101 ELCU-200 N�k NA CONTROL SET POIIVT SHALL BE 50 FC. PROVIDE TIME CLOCK ZONE WITH MANUAL DIMMING CONTROL LIGHT FIXTURES 1/E8.1 <br /> APPROPRIATE DEADBANDS TO PREVENT ENABLED/DISABLED VIA TIMECLOCK IN BMS. <br /> CYCLING. <br /> . <br /> h,,,. ��A <br /> � ^M1 ` � � � <br /> CONTINUOUS 0-1QV DIMMING. PRIMARY AND �``�`==� � � _� <br /> SECONDARY DAYLIGHTI�JG ZONE. DAYLIGHT ���TM � <br /> TIIViE CLOCK ZONE WITH MANUAL DIMMING CONTROL. LIGHT FIXTURES <br /> 180 (b) OPEN OFFICE LMRC-213 LMDM-101 NA LMLS-500 LMIO-101 ELCU-200 NA NA CONTROL SET POINT SHALL BE 50 FC. PROVIDE ENABLED/DISABLED VIA TIMECLOCK IN BMS. 1/E8.1 _ � .� <br /> APPROPRIATE DEADBANDS TO PREVENT <br /> CYCLING. � <br /> CONTINUOUS 0-10V DIMMWG. PRIMARYAND � <br /> . ` Q <br /> SECONDARY DAYLIGHTING ZONE. DAYLIGHT � <br /> CONTROL SET POINT SHALL BE 50 FC. PROVIDE DIMMING VACANCY SENSOR ZONE. FIXTURES CONTROLLED VIA MANUAL ~ <br /> 180A OFFICE LMRG212 LMDM-101 LMDG100 LMLS-500 LMIO-101 NA NA NA 4/E8.1 � �' <br /> APPROPRIATE DEADBANDS TO PREVENT DIMMING. z r� w <br /> ; CYCLING. OCCUPANCY STATUS OUTPUT TO BM p � � <br /> cn <br /> SYSTEM. � � � � <br /> a <br /> f W z � <br /> � u a <br /> CONTINUOUS 0-10V DIMMING. PRIMARY <br /> DAYLIGHTING ZONE. D,�YLIGHT CONTROL SET pIMMING VACANCY SENSOR ZONE. FIXTURES CONTROLLED VIA MANUAL 4 E8. � � <br /> 180B OFFICE LMRC-211 LMDM-101 LMDC-100 LMLS-40Q LMIO-101 NA NA N� POINT SHALL BE 50 FC. PROVIDE APPROPRIATE DIMMING. � 1 r..� � <br /> DEADBANDS TO PREVENT CYCLING. w � � <br /> �CCUPANCY STATUS OUTPUT TO BM5 SYSTEM. � � � � <br /> 181 TEI.ECOM OFFICE LMRC-211 LMDM-101 LMDG100 NA LMIO-101 ELCU-200 NA NA OCCUPANCY STATUS OUTPUT TO BMS SYSTEM. DIMMING VACANCY SENSOR ZONE. FIXTURES CONTROLLED VIA MANUAL 4/E8.1 �z <br /> - C�IMMING. <br /> 1$1A TELECOM �FFICE LMRG211 �MDM-101 LMDG100 LMLS-400 LMIO-101 NA NA NA OCCUPANCY STRTUS OUTPUT TO BMS SYSTEM. DIMMING VACANCY SENSOR ZONE. FIXTURES CORITROLLED VIA MANUAL 4/Eg.1 <br /> - DIMMING. ' <br /> ' 182 LAB LMRG101 LMDW-100 LMDW-100 NA NA NA NA NA NA <br /> ON/OFF UACAiVCY SENSOR ZONE. SPACE CONTROLLED VIA ON/OFF 3/E8.1 <br /> - SWITCHING � <br /> ' � CONTINUDUS 0-10V DIMMWG. PRIMARY AND Ur � � <br /> SECONDARY DAYLIGHTING ZONE. DAYLIGHT z Z (� <br /> CONTROL SET POINT SHALL BE 50 FC. PROVIDE DIMMING VACANCY SERISOR ZONE. FIXTURES C�JNTROLLED VIA MANUAL ~ W � <br /> 183 TELECOM C7FFICE LMRC-212 LMDM-101 LMDG100 I.MLS-500 LMIO-101 ELCU-200 NA NA 4/E8.1 <br /> APPROPRIATE DEADBANDS TO QREVENT D I M M I N G. � � <br /> CYCLING. OCCUPANCY STATUS OUTPUT TO BM _I W W � <br /> SYSTEM. ; � o � � W � <br /> a Z <br /> o � [�] � � ,. <br /> CONTWUOUS 0-10V DIMMING. PRIMARY AND � � �/ �"'� <br /> � ° � � � <br /> SECONDARY DAYLIGHTING ZONE. DAYLIGHT h � <br /> CONTROL SET POINT SHALL BE 50 FC. PROVIDE DIMMING VACANCY SENSO� ZONE. FIXTURES CONTROLLED VIA MANUAL o ' W <br /> 183A TELECOM OF�ICE LMRG212 LMDM-101 LMDG100 LMLS-500 LMIO-101 NA NA NA � 4/E8.1 s � z � <br /> � APPROPRIATE DEADBANDS TO PREVENT DIMMING. Z � � H � � <br /> CYCLING. OCCUPANCY STATUS (�UTPUT TO BM y � H H F-- W <br /> SYSTEM. <br /> _ `"' H � � <br /> LMSW-101 LMIO-101 ELCU-200 NA NA TIME CLOCK ZONE WITH MANUAL ON/OFF CONTROL. LIGHT FIXTURES � W W <br /> 184/188 HALL/WAITING LMRG101 NA NA Nq ENABLEDJDISABLED VIA TIfViECLOCK IN BMS. 1/E8.1 W � N <br /> � � � <br /> NA NA NA MANUAL ON/OFF CONTROL PER C405.2.2, EXCEPTION 1 AND EXCEPTION 3. (V/A � <br /> 185 COMM/ELEC CLOSET NA LINE VOLTAGE NA NA NA NA <br /> � � � <br /> : LMDM-101 LMDG100 NA NA DIMMING VACANCY SENSOR ZONE. FIXTURES CONTROLL.ED VIA MANUAL 4/E8.1 �" <br /> 186 HEARING TEST LMRC-211 NA NA NA <br /> , NA DIMMING. <br /> LMDM-101 LMIO-101 NA NA TIME CLOCK ZONE WITH MANUAL DIMMING CONTROL. LIGHT'FIXTURES <br /> 187 KITCHEN LMRG211 NA NA NA Nq ENABLED/DISABLED VIA TIMECLOCK IN BMS. 1/E8.1 <br /> LMDM-101 LMDG100 LM10-101 NA NA OCCUPANCY STATUS OUTF'UT TO BMS SYSTEM, DIMMING VAEANCY SENSOR ZONE. FIXTURES CONTROLLED VIA MANUAL SHEET TITLE: <br /> 189 CONFERENCE LMRC-211 NA NA DIMMING. 4/E8.1 FIRST FLOOR LI�HTING <br /> DIMMING VACANCY SENSOR ZONE. FIXTURES CONTROLLED VIA MANURL CONTROLS <br /> ' LMDM-101 LMDC-100 LMIO-101 NA NA O�CUPANCY STATUS OUTPUT TO BMS SYSTEM. 4/E8.1 <br /> 190 CONFERENCE LMRG211 NA NA DIMMING. <br /> NA EXTERIOR LIGNTINC� LMRC-311 LMSW-101 NA LMPO-200 LMIO-301 NA NA NA PHOTOCELL CONTROL WITH MANUAL OVERRIDE. N/A <br /> � DATE: 04/08/16 <br /> )OB NQ.: 14008 <br /> � <br /> ONE INCH AT FULL SCAL.F. <br /> IF NOT, SCALE ACCORDINGLY <br /> SHEET: <br /> . � � FIR�T FLC��R �IC�HTIN� CONTROLS IVIAT'RIX ■ <br /> • " . ' E2.1 B <br /> SHEET 62 OF 95 - <br /> _ _ � <br />