Laserfiche WebLink
- t� ��- � <br /> -� � <br /> ' ` �� n.� ' <br /> - - - - %� <br /> 9 � G � . <br /> (E) GENERATOR �. �� <br /> � 400kW <br /> , � <br /> , � ^ i 480Y1277V,3P,4W •� s � <br /> � 600�3P � SHEET �IOTES: r`� '� ` <br /> c � � � <br /> - - - - , 1. EXISTING CONDUIT AND CONDUCTOR SIZES ARE 281� �;CC����_�._:_.EF� A�tL <br /> 2 SETS EACH ' ., cv�r?��rr, +r��i �a�2�� <br /> � ) BASED ON RECORD DRAWINGS. <br /> (1) 3-1/2"C ' ;���ori�: ��5.��l.�o?r <br /> � (4) 350 kCMIL + , 2. REFER TO SHEET E9.3 FOR FEEDER SCHEDULE. F^�: r1�.'1�.���� <br /> (1)#1 AWG G <br /> � � MTS#1 • <br /> � ` � "STANDBY" � <br /> � � � 600A, 4-POLE H A R � I S <br /> FROM E MAIN _ _ NEMA 3R ENC. FLAG NOTES. <br /> ( ) �-- Hargis Engineers,Inc. ` <br /> SWITCHBOARD � RE-USE SPARE BREAKER IN PANEL OA-UP�-DP. 12U1 Third Avenue, Suite 604 <br /> � 6dON <br /> Seattle,WA J8101 <br /> _ _ � PROVIDE CIRCUIT BREAKER COMPATIBLE WITH <br /> EXISTING SWITCHBOARD. AIC RATING SHALL t� 2Q6.448.3376 <br /> E A7�S <br /> _ (2) SETS EACH � ,� i (STANDBY" f� 206.448.4450 <br /> �� �� 1 3-1/2 C � MATCH EXISTING. <br /> (E) DIST. BOARD OEL-1-A � ) 600A, 3-POLE 3 - w� hargis.biz <br /> � 480Y/277V,3Q�,4W (4) 350 kCMIL + � - - � /� . <br /> NEMA 3R ENC. COORDINATE SHUT DOWN OF OA-UPS-DP WITH <br /> 600 AMPS (1)#1 AWG G r - - - - - - - - - - - - - � DISTRICT FOR CONNECTION TO NEW FEEDER. � <br /> - - - - - - - - <br /> - - - - - - - - -a-- - - - - - - I : . <br /> ( � � � REMOVE EXISTING PANEL 'OEL3', ASSOCIATED �,� , ,, ti,�E3Np � <br /> � EPM <br /> ( � � FEEDER, CONDUIT BACKTO DIST. BOARD 'OEL1A'. '`�.r... q , <br /> I � 600A/3P I � I ' KEEP 4QOA/3P BREAKER IN PANEL 'OEL1A'AS `��:;;-,,T ;� � �- �� <br /> � SPARE. .. � � �, <br /> I I � , <br /> ( � : <br /> r- - - - - - - - - - --i I � I `� <br /> i i � Q : <br /> i � � � � � � <br /> i I I � . ( . I _ �, � . .. <br /> � 2 400A/3P AF � <br /> � �N i � 4 0 0 A/3 P i ��3 0 0 A/3 P �b 2 0 0 A/3 P � 4 0 0 A/3 P � �i C 2 2 5 A/3 P A T � ( <br /> � , � <br /> � <br /> G � � I �---A R E A O F W O R K , . <br /> . <br /> i-- - -I - - - - - - - - - - - - -I-- - - - - - - � I ,-v � t- <br /> � (1) 3-1/2"C � �1) 3-1/2"C � ( ' x z � U�j , <br /> = � i (4) 500 kCMIL +� (4} 500 kCMIL +i 225N � ' � ,n ' <br /> O � � <br /> � (1)#3 AWG G � (1)#3 AWG G <br /> H H <br /> v I � C <br /> � � � � W Z W <br /> I � Q 1.�,..—AREA OF WORK � OEH 3A � , � � a <br /> ( I I „ 225A � <br /> I I <br /> I I � �' <br /> I (E) PANEL � I I I I LOCATED IN E��,DC , � � ; <br /> I "OEL3" I � _ �—J _ _ _ � _ _ _ _ J �(E)UPS SYSTEM pISTRIBUTION 42,418 � � � � <br /> , 1_ - _ _ ._ _ � - - - -J � SWITCHBOl��2D (UDS) 1000A, <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> _ - - - - � i 480V,3Q1,4W , i � � � �� <br /> I (E) PANELBOARD "OEL1" ' ' <br /> � 480Y/277V,3QJ,4W ¢ I � <br /> � � 400A/3P � z <br /> 600 AMPS I � ST { ST { U U ', c.W� U � c� � c� � c� � c� � <br /> , ° I , � � � � Q Q Q Q o 0 0 0 <br /> i � � a � � a � � � M ' <br /> � _ � �-- - - - - - � - - � '- - � - - � - - - - - - - - - - - - - - � <br /> � I 350 TO 200KVA <br /> IPDU-A PDU-B PCU UNIT <br /> � �N � 60A/3P � 50A/3P � 40A/3P � 100A/3P I , o aaov E XFMR PDU-C PDU-D � <br /> � � �— —� c , � � � <br /> I � � � 150KVA z z ( ^ = <br /> • � r — - - - - - - - - - - - - - - - - - - - - - - � 2o$Y � v � <br /> .. - - - - - - - - - - — - - - - -- - <br /> (1) 1-1i4"C (1) 1"C ��) ���C <br /> #2 � — �zov 1--1 ; <br /> 3 #4 AWG + (3}#6 AWG + (3)#6 AWG + (1) 1-1/2"C � � � <br /> � ) - � , <br /> — 4 #1AWG + � - - - - - - � <br /> - 0 AW G _ _ 1 #10 AWG G - - (1)#10 G � � <br /> - - 1 #1 G ( ) <br /> O - - - - - - - - - - - - - - = — - - - - — - - - - - - - - - - —�— - - � --� � � �', <br /> �o asov � _ �o aaov � �n asov � (1)#6 AWG G <br /> I E)XFMR (E)XFMR (E)XFMR � '� � d � � � <br /> i i � _ �� I �,�,T-0EP3" I � "T-ONXP" ( (E)OA-UPS-DP a <br /> � � T OEP2 � i � � 208Y/120V a � � ( p � � O � .. <br /> L--�- -1osv� 45KVA �is- -izov� 45KVA zosv 30KVA , � <br /> �is_ �20� � � � 400 AMPS o � � � � � � <br /> . {�� 2„C ��� 2,•C (1) 1-1/2"C � n � 60A/3P , d- � � � ° <br /> + 4 #1/0 AWG + (4)#1 AWG + , � a � � � v J <br /> {4)#1/0 AWG ( ) � , <br /> a (1)#6 AWG G �� (1)#6 AWG G a (1)#6 AWG G � �i � �5 � �i a ni ', m ai «� � «� � i a � i p � O � � �/, <br /> �, M c� (E} PANEL i � o � o � o � o � o � a � a � a � a � d � a � � � a � a � � z � ~ � 6.L , <br /> � a� � �.d� � � �C � "OEL2" bo bo bo bo bo bo o ' o 0 0 0 0 o I o ( `� H <br /> . � N � � o � � � �.�n � (1) 1-1/4"C � _ � r- �- r- r- r- t- r- t- �- �- r- I � I I � F- �„� �,('� �'�"'�. <br /> N I � I I ( I , � <br /> I I �J L��I (3)#4 AWG + - - - - - - - - - - - - - -� <br /> I�1 � I � ~ � <br /> — - - — - - — - - <br /> E PANEL (E) PANEL (1)#10 AWG G - - - - - - - - - - -I- � <br /> (E) PANEL ( ) <br /> 100N 100N 100N 100N 100N 100N 100N � 100N ( � � � � <br /> , "OEP2" ,�OEP3" , t,ONXP,� <br /> � � � � <br /> �o aaov1 �E)XFMR , � I i � � � ' <br /> � � "TOEP" I O � <br /> 208Y I I I I I I I I I I I I I I 1 I <br /> �Y_ ,zo� 45KVA I I � I I � I I I I I I I I � I I � � � , <br /> L� � L� L� � u u � � � <br /> (E)i'HNEL (E)PANEL (E)PANEL (E)PANEL (E)PANEL (E)PANEL (E)PANEL I PANEL I <br /> , UL1 OA-UPS-1E OA-UPS-2E OA-UPS-4E OA-UPS-1W OA-UPS-2W OA-UPS-3W � "OA-uPS-4W" � <br /> (1)2"C 100A �100A 100A 100A 100A 100A 100A � 100A ( <br /> (4)#1/OAwG + �- - - - - - -� SHEETTITLE: <br /> ' � (1)#6 AWG G <br /> ONE-LINE �IAGRAM <br /> EMERGE�ICY POWER <br /> _ � � <br /> � a C n� 100N �AREA OF WORK : <br /> r �n 100A/3P <br /> {E) PANEL , . � <br /> ,�OEP" <br /> � i , <br /> (1) 1-1(2"C i i <br /> (4}#1 AWG + � <br /> (1)#6 AwG G . . DATE: 04/08/16 <br /> (E)PANEL _ - <br /> OEP3A JOB NO.: 14008 <br /> : 100A � <br /> � ONE INCH AT FULL SCALE. , <br /> IF NOT, SCALE ACCORDINGLY j <br /> � SHEET: , <br /> i ¢� i ' <br /> � 0 ( � <br /> L� <br /> y �E� PANE� � OI�E—LII�E DIAGRAM EMERGENCY POWER; ■ <br /> � "OEP1A" E9•2 SCA�E: NONE <br /> , SHEET 71 OF 95 <br /> ; <br /> � <br /> j � .. . � <br /> ; ;;; <br />