1 (
<br /> �A,�+'d'^I. —;
<br /> �' �, �.� � .r�"`° "
<br /> � � t
<br /> CONSTRUCTION GENERAL NOTES � �� - ;� � �
<br /> �m .;.�
<br /> 1. CONFLICTS BETWEEN SITE CONDITION5 AND DRAWINGS SHALL BE BROUGHT TO THE
<br /> IMMEDIATE ATTENTION OF THE ARCHITECT.
<br /> Nelco Architecture, Inc.
<br /> SUITE 2. ALL WORK SHALL BE ERECTED AND INSTALLED PLUMB, LEVEL, SQUARE AND TRUE AND IN
<br /> PROPER ALIGNMENT, u.N.o. a licensed affiliate of Nelson Worldwide, Inc.
<br /> ##100 SUITE #125
<br /> 3. ALL DIMENSIONS ARE TO FINISH CONSTRUCTION, U.N.O. DIMENSIONS NOTED"HOLD"
<br /> MUST BE ACCURATELY MAINTAINED,AND SHALL NOT VARY MORE THAN f 1/8" WITHOUT
<br /> OFFICE CONFERENCE OFFICE OFFICE 8 TYP. OPEN OFFICE OFFICE OPEN OFFICE OFFICE SHARED OFFICE WRITTEN INSTRUCTION FROM ARCHITECT. "ALIGN" MEANS TO ACCURATELY LOCATE
<br /> A9-1 FINISHED FACES IN THE SAME PLANE. DIMENSIONS NOTED "CLEAR"ARE MINIMUM
<br /> 119 108 109 110 OFFICE 112 113 114 115 116 DIMENSIONS WHICH MUST BE MAINTAINED WITHOUT EXCEPTION. DIMENSIONS MARKED 1200 Fifth Avenue
<br /> t MEAN A VARIANCE NOT GREATER THAN 1 INCH, VERIFY DIMENSIONS EXCEEDING Seattle, WA 98101
<br /> / ` 111 TOLERANCE WITH THE ARCHITECT, ALL DIMENSIONS TO THE EXTERIOR WINDOW WALL Phone: (206)408-8500
<br /> ' , ` ARE TO THE FINISH FACE OF WALL BELOW SILL, U.N,O. Fax: (206)223-4990
<br /> � t: � , f 6�-0�� �-- _.
<br /> , `� 4. ALL EXISTING FLOORS, PARTITIONS, DEMISING WALLS,AND CORRIDOR WALLS TO
<br /> REMAIN ARE TO BE PATCHED AND REPAIRED ASSEMBLY TO MATCH ADJACENT SURFACES.
<br /> 105
<br /> 5. PATCH AT ALL NEW AND EXISTING PENETRATIONS AT FLOOR AND CEILING SLABS,
<br /> � �'S` lA 4 SHALFTS TO MA NT I�N FIRE/SMOKE�AN ACOUSTICALORATINGSOPATC�H FIR PROOFING
<br /> UP 107 � � ��. A7-1 �s" �
<br /> AT ALL NEW AND EXISTING LOCATIONS WITH EXPOSED STRUCTURAL STEEL.
<br /> a �� �'� ,(�, f,
<br /> I � �
<br /> -� � '� 1B 6. ALL GLASS SHALL BE CLEAR TEMPERED GLAZING TONG MARKS SHALL NOT BE VISIBLE.
<br /> FFC � ' CLEAN &POLISH ALL GLASS PRIOR TO PROJECT DELIVERY.
<br /> � 2t 108 108 6'-0" 7. ALL PARTITIONS ARE TYPE 2A/B U.N.O. ALL INFILL OF DOORS/WALLS/OPENINGS SHALL
<br /> �� MATCH AND BE FLUSH WITH EXISTING ADJACENT PARTITION CONSTRUCTION.
<br /> � � �-� ,.., �� 8. WHERE PARTITIONS ARE ATTACHED TO EXTERIOR CLOSER,CENTER PARTITIONS ON
<br /> t�s ' ;�� WINDOW MULLIONS, PERPENDICULARTO PERIMETER WALL, U,N.O. REFERTO DETAIL
<br /> � 6/A9-1. CONSTRUCTION TO MATCH BUILDING STANDARD.
<br /> ELEV. 104 9. PARTITION DEPTH AT FIRE EXTINGUISHER CABINET LOCATIONS SHALL ACCOMMODATE
<br /> � OPEN OFFICE 1B 18" CLR. 0 3B 1B FULL CONCEALMENT OF RECES5ED CABINETS OR PARTIAL CONCEALMENT OF
<br /> ELEVATOR 10� �
<br /> SEMI-RECESSED CABINETS AS SPECIFIED BY THE MANUFACTURER. REFER TO MOUNTING
<br /> LOBBY 2B F � -� N - 8�� HEIGHT DETAIL 7/A9-1.
<br /> �
<br /> �
<br /> —� 10. EXTEND GYPSUM WALLBOARD AND FRAMING AT EXISTING PARTITIONS AND COLUMNS,
<br /> � 11 �o TO 6° (MINIMUM) ABOVE SUSPENDED CEILING WHEN NEW CEILING HEIGHTS ARE ABOVE
<br /> ELEV � _ �
<br /> `� z�-o�� ����-������ ,�� ���� u, , ,
<br /> �
<br /> 1B �� 101 �;<�� llg THE EXISTING CEILING HEIGHT PER DETAIL 2/A9-1 .
<br /> ����
<br /> (� � �� 11. ALL PARTITIONS ABUTfING COLUMNS ARE TO ALIGN WITH THE FACE OF THE COLUMN,
<br /> �
<br /> 107 F � � � � 5 100 � �� �� � � STORAGE �" `�� � � BREAK U.N.O.
<br /> < ` ` I� : � ,�`. 119 m. ^�
<br /> � � ��- 117 12. WHERE NEW PARTITIONS ABUT EXISTING SURFACES, REMOVE EXISTING CORNER BEAD
<br /> � 1B — x��� �a ,� � 103 _
<br /> � �—— F ,�
<br /> 2 AND PROVIDE SMOOTH FINISH AT INTERSECTION.
<br /> 4� ��� � � j. I 3'-5" A7-1
<br /> 2B SERVER I 13. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO
<br /> 10 1 ��� � 120 I VISIBLE JOINTS. PROVIDE LEVEL 4 FINISH, U.N.O,
<br /> i `. A7-1 � � ,� ., DN
<br /> i � 14. ALL EXPOSED GYPSUM BOARD EDGES TO HAVE VINYL OR METAL EDGE TRIM. Consultant:
<br /> i 107 i � �' 102
<br /> HALLWAY 15. REFER TO PARTITION TYPES FOR PARTITION THICKNESS.
<br /> x � � UP Descri tion: No: B Date:
<br /> 1� i � r 106 � 118 P � Y�
<br /> i � 2B C� _�.� .:, ,. .p �, .. REVIEW SET HF 05/18/18
<br /> , _ _ � � 4 : ,vo accEss 16. CONSTRUCTION OF FIRE-RATED PARTITIONS, INCLUDING TAPING AND FINISHING OF
<br /> `' � assuMEo wn« �' ' PERMIT SET HF 05/22/18
<br /> - :" ,_ - � ��,� - . ,- t, �� GYPSUM WALLBOARD FOR FULL HEIGHT TO STRUCTURE ABOVE,SHALL BE IN
<br /> � � `�� � �; THICKNESS(TYP.) * ACCORDANCE WITH UL SPECIFICATIONS TO ACHIEVE RATING INDICATED.
<br /> �, `"'� �` ��'' �'�
<br /> a
<br /> 17. ACOUSTICAL (SOUND-ISOLATION) PARTITIONS SHALL BE SEALED FOR FULL HEIGHT TO
<br /> � o EQ. EQ. PREVENT PASSAGE OF AIRBORNE SOUND. TAPE AND FINISH ALL GYPSUM WALLBOARD
<br /> � a MAIL OFFICE CONFERENCE CONFERENCE CONFERENCE RECEP ION WAITING COMMON CORRIDOR JOINTS AND FASTENERS(INCLUDING ABOVE SUSPENDED CEILING). CAULK AT
<br /> ''� PERIMETER AND SEAL AT ALL PENETRATIONS. REVIEW EXISTING ARCHITECTURAL
<br /> � � 106 105 104 103 102 101 100 ELEV. DRAWING FOR POTENTIAL RATED WALLS.
<br /> z ••
<br /> O °�
<br /> .fl
<br /> J � �"� .. "- f i` �` ,
<br /> .�::�: .. ....: 5rt r :..,.,.., , «:_.. .. : � � .�r �..
<br /> �3�t'4T:
<br /> ,., . ..:
<br /> '� � ��" ' `� "� ���"��� ��� �"' V�!! � , 18, WHERE PARTITION5 EXTEND ONLY TO UNDERSIDE OF SUSPENDED CEILING, SECURE THE
<br /> w � NO ACCE55
<br /> z� a assuMeo wn« f TOP TRACK TO THE EXPOSED CEILING GRID. PROVIDE A COMPRESSIBLE GASKET
<br /> � Q rHicKNEss irrP.� I BETWEEN THE TOP TRACK AND THE CEILING GRID. PROVIDE TAPABLE METAL J-BEAD AT
<br /> � a TOP OF GYPSUM WALLBOARD, WITH NO JOINTS VARYING MORE THAN 1/8"OVER 6'-0"
<br /> � � � ❑ ❑ � ❑ AND NO JOINTS GREATER THAN 3/16", U.N.O. CAULK PERIMETER AT TOP OF GWB.
<br /> aai � � '�
<br /> BRACE TOP OF PARTITION PER DETAIL 1/A9-1.
<br /> o � ,= ��u
<br /> z 00 � ��
<br /> 19, PROVIDE GROUNDS AND BLOCKING IN METAL STUD WALL FRAMING FOR SUPPORT OF
<br /> a; °�' �e CASEWORK, SHELF-STANDARDS, A/V DEVICES, FURNITURE, ETC. ACL CONCEALED
<br /> ��;
<br /> �� o � � LUMBER AND BLOCKING TO BE FIRE TREATED. COORDINATE BLOCKING REQUIREMENTS
<br /> o � �.,
<br /> WITH FURNITURE&AV INSTALLERS. WHERE BLOCKING OR ADDITIONAL STUDS ARE
<br /> � � /V� ��:; REQUIRED AT EXISTING PARTITIONS,THEY ARE TO BE PATCHED AND REPAIRED. SEE
<br /> � � �� CONSTRUCTION PLANS FOR WALL-MOUNTED MARKERBOARD, MONITORS&PROJECTION
<br /> �
<br /> � �, c� �; SCREENS; PROVIDE BLOCKING PER MANUFACTURERS' REQUIREMENTS.
<br /> U
<br /> � � O ,
<br /> Q ¢ � ��' 20. ALL HINGED DOORS TO BE 4" FROM NEAREST PERPENDICULAR PARTITION, U.N.O. EVERETr OFFICE TOWER
<br /> DIMENSIONS LOCATING DOORS ARE TO THE INSIDE EDGE OF JAMB. ALL DOORS SHALL
<br /> HAVE 1'-6" CLEAR ON THE STRIKE/PULL SIDE OF DOOR AND 1'-0 CLEAR ON THE
<br /> i � � � c
<br /> � � � ❑ ���`t`�� 5TRIKE/PUSH SIDE (IF THEY HAVE BOTH A LATCH AND A CLOSER). VERIFY AND ADVISE 27Z2 COLBY AVENUE
<br /> 3 � Z � UP ,��,�'� : ARCHITECT OF EXCEPTIONS PRIOR TO CLOSING OUT PARTITIONS.
<br /> � �; EVERETT, WA 98201
<br /> � � �� 21. PROVIDE DOUBLE STUDS AT DOOR JAMBS. INSTALL ADDITIONAL STUDS IN EXISTING
<br /> � � ��3
<br /> a Q � `€�`�°
<br /> 0 0 � � PARTITIONS AT NEW DOOR OPENINGS IN ORDER TO PROVIDE DOUBLE STUDS AT JAMBS.
<br /> �� `'�'� � 22. METAL STUDS AT PARTITIONS TO RECEIVE CERAMIC TILE ARE TO BE 20 GAGE
<br /> % = U
<br /> � Q � (MINIMUM) @ 16" O.C. (MAXIMUM). REFER TO THE FINISH PLANS FOR TILE LOCATIONS. Building:
<br /> a �
<br /> � � 23. PROVIDE DIAGONAL STUD BRACING TO SLAB ABOVE @ 48"O.C. AT DROP
<br /> � � UP ARCHES/BULKHEADS PER DETAIL 1/A9-1. R1'-�INIER TITLE VFFICE
<br /> �
<br /> � 0 24. PROVIDE DIAGONAL BRACING TO SLAB AT DOUBLE STUDS AT DOOR OPENINGS.
<br /> � � � �� 25. PROVIDE VERTICAL CONTROL JOINTS 30' O.C. MAX. IN ALL GWB PARTITIONS LONGER 2722 COLBY AVENUE
<br /> a o DN �� �
<br /> :�, � � `� {
<br /> m ��E � ; � � `` � �,�
<br /> � ` THAN 30'. WHEN POSSIBLE CONTROL JOINTS SHOULQ BE LOCATED ABOVE THE CORNER ETT, WA 98201
<br /> � � - � � } � �,.� a� �:� _�.: �..� �� �v � ' �'�� EVER
<br /> v �, � � � Project Title&Address:
<br /> 0
<br /> � � ,� .�.�,� OF A DOOR.
<br /> � +,
<br /> � �
<br /> v �°� CONSTRUCTION PLQN KEYNOTES O CONSTRUCTION PLAN
<br /> .� �
<br /> �`° � LEVEL 01 CONSTRUCTION PLAN
<br /> � � 1 100 NEW ADA COMPLIANT BUILT-IN RECEPTION DESK WITH SOLID SURFACE TRANSACTION
<br /> o TOP, PLASTIC LAMINATE DESK TOP AND VERTICAL SURFACE,AND(2) BOX-BOX-FILE
<br /> � �i A1-1 1/8" = 1'-0"
<br /> ^ PEDESTALS.
<br /> � �
<br /> � �
<br /> �'' o
<br /> � � Sheet Title:
<br /> Qi 101 NEW LOWER CASEWORK WITH SOLID SURFACE COUNTERTOP,CABINEf WITH
<br /> � �
<br /> ADJUSTABLE SHELF AND GROMMEf.
<br /> � �
<br /> � � CONSTRUCTION LEGEND 102 NEW ADA COMPLIANT LOWER CASEWORK WITH SOLID SURFACE COUNTERTOP, ��y
<br /> w w CABINETS, (2)GROMMEfS, AND ADJUSTABLE SHELF. PROVIDE COPPER COLD WATER k�c;t�i�tx�,.�,!
<br /> LINE FOR COFFEE MAKER. �w►�c'Ira?r s ;
<br /> Z ?� �
<br /> NOT IN CONTRACT(NIC) � NEW DOOR&FRAME 103 NEW ADA COMPLIANT UPPER AND LOWER CASEWORK WITH PLASTIC LAMINATE � +���
<br /> �
<br /> COUNTERTOP CABINET DOORS WITH ADJUSTABLE SHELVES SINK AND FAUCET AND �{A��r'�'��a���'���
<br /> � � � +� a.� <,� �t �.�ii��,r��� �-.._�„ � �
<br /> a a EXISTING WALL TO REMAIN DRAWERS. � � �
<br /> � � F�C FIRE EXTINGUISHER CABINET
<br /> �; � NEW WALL
<br /> 104 NEW PLASTIC LAMINATE LOWER CASEWORK WITH FILING CABINETS UNDER COUNTER.
<br /> � @ 105 MODIFY EXISTING SIDELIGHTS AND PROVIDE NEW 5TOREFRONT WINDOW,SEE Seal:
<br /> r�
<br />� � � R� � ALIGN
<br /> ELEVATION 4/A7-1.
<br /> � � � NEW FULL HEIGHT RELITE Proj. No: 18.01772.00 Designer: EB
<br /> � a
<br /> �
<br /> M M 106 INFILL LOCATION OF REMOVED DOOR TO MATCH ADJACENT. Drawn By: HF Reviewed By: MDE
<br /> � `�,° Project Manager: KF Approved By: MDE
<br /> `•V ,:,�; 107 UPGRADE TO DEMISING PARTITION PER DETAIL 2/A9-1.
<br /> �
<br /> o � 108 PATCH/REPAIR DAMAGED SURFACES AFTER REMOVAL OF WOOD CLADDING. PREP TO � � �
<br /> a
<br /> N
<br /> C � RECEIVE NEW FINISHES.
<br /> � �
<br /> �n u'
<br /> � � ALL DIMENSIONS AND CONDITIONS MUST BE CHECKED AND VERIFIED
<br /> � � ON SITE BY THE CONTRACTOR AND SUB-CONTRACTORS PRIOR TO
<br /> a p PERFORMING THE WORK.THE PROJECT MANAGER SHALL BE NOTIFIED IN
<br /> a a WRITING OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK.
<br /> c0 NELSON WORLDWIDE,INC. 2018 ALL RIGHTS RESERVED
<br />�
<br />
|