Laserfiche WebLink
''� - _ _ <br /> . _ <br /> E1 UNIT VARIATIONS <br /> A - SINGLE PORCH/ NO POPOUT AT REAR 15'-4" 15'-4" <br /> ' : <br /> , ,'-5�» 4>_3�4» 4,�3�4,� 5,_4„ <br /> B - SINGLE PORCH/ POPOUT AT REAR �1`-5%n 4'-3�4" 4'-3�q." 5'-4" ' <br /> C - DOUBLE PORCH/ NO POPOUT AT REAR " <br /> � , <br /> D - DOUBLE PORCH/ POPOUT AT REAR <br /> � ...... ...... � <br /> ...... ...... �� ( <br /> . E - SMALL DOUBLE PORCH/ NO POPOUT AT REAR � � E G R E S S � � � 6-0 5-6 D B L S L • <br /> .......... ............... ........ ...;..; ......... <br /> .�..... ... .....� �.,....... , » � ', _ <br /> F - SMALL DOUBLE PORCH/ POPOUT AT REAR � 6-0 5-0 DBL SL � � C� 8-0 A.F.F. � <br />� � � � 7'-4" A.F.F. � 1 � `� �� � <br /> �N ' `��� . - i , , <br /> SEE BUILDING PLANS FOR WHERE ; D1 \ � � � --- ---------------------------------------- --- �; - -r � <br /> VARIATIONS OCCUR 1 � � I� I �'�;�� �i � ; <br /> �r cn UL APPROVED <br /> � � j °- �� � � ELECTRIC FIREPLACE �; �� �� ' �{ <br /> i m � � i � i FLOOR I 1,Y� � � >� �..; � � !I �. <br /> �' � � � � � � � e � t � ; <br /> �� � � I; �� BELOW TILE HEARTH �� �. � <br /> INSULATION - � � � <br /> � <br /> FOUNDATION PERIMETER - R-10 RfG(D UPPER LEVEL PLAN �5 ����rtt) Wpy, �t��#e 2T�,'; <br /> INSULATION TO A DEPTH �F 24" OR TO TOP U N IT E1 B E1 D & E1 F W�REAR, POPOUT �`������"�'���`������� :�����'� <br /> OF FOOTING AT NEATED PERIMETER i MIDDLE LEVEL PLAN <br /> ��4„=�,_0„ Pa4����54 713Q F ��S�r�8�2Q�'; <br /> WALLS: 2x6 WALLS WITH FIBERGLASS BATTS U N IT E1 B, E1 D & E1 F W�REAR POPOUT POP-OUT ABOVE AT UNIT E1B, E1D & E1F �l�bR�"��rz��Ibra[td#ar;����r� r <br />� OR BLANKETS - R21 1/4"-1'-0" (SEE ELEVATfONS WHERE OCCURS) <br /> ,� .,}'8 �,.. ..:"< h y.:;': . , .:.,.: .,....::::,.�?: <br /> FLOORS QVER UNHEATED SPAGES - R-30 15'-4" 15'-4" <br /> 15'-4" , 5'-8314 9 -��4 � 5'-9" 9'-7" 5052 REGISTERED . <br /> ATTICS AT TRUSSES - R-49 , 5'-g3�4" 6'-103�4" 2'-8%2" � <br /> (R-38 SNALL BE DEEMED TO SATlSFY THE 1 , FLOOR ABOVE � ARCHITECT <br /> REQUIREMENT OF R-49 WHEREVER THE FULL 6-0 5-6 DBL SL <br /> HEIGHT OF UNCOMPRESSED INSULATION EXTENDS <br /> � 6-Q 5- DBL SL � . � D1 � �----- ----------� � <br /> OVER THf WALL TOP PLATE AT TNE EAVES) I � 7'- A.F.F. ' '.....e...••.•. � 8- A.F.F. ••.• •.••••.•••, <br /> .�.. ..� ' ..........\\`,. ---�� 1 �-- � �--------- <br /> ... ........ .. .... <br /> ............... ...... ............ � <br /> EXTERIOR DOORS: DOORS BETWEEN HEATED t EGRESS � I� � `�;�, � �� �.r WALL Q W.H. STAT�B OF WA HENGTON <br /> AND UNHEATED SPACES SHALL BE U=0.30 <br /> OR BETTER � D1 \ � i i -- -----------------------------------D ---��. \\\.ir j' � , <br /> t 1 � � _ � \ ` � \� 8-0 7 0 SOHQ <br /> � i � �� � UL APPROVE ,�. I i WM <br /> WINDOWS: ALL WINDOWS AND SGQ TO HAVE � � Q i � � � ELECTRIC FlREPLACE �, �� ` 15 11 14 1 � <br /> U FACTOR �F U 0.30 OR BETTER I� m � � �� � I FLOOR � D5 D2 D5 D1 3'-4" � <br />� INSULATE UNDER STAIRS AND W WALL � o I "' � '�o I� BELOW T(LE HEARTH j� � � ;, <br /> CAVtTIES ABOVE BOTTOM OF STRINGERS - �� � � �� I �QPTIONAL) 1 � <br /> i' I� Bedroom � � � _ ,1 1, . , NOTE: PER IRC R3Q2.6 MW. � ' <br /> N ,' 8,-0„ 3_5�2„ ,,-2,� 2� �%' '� � Livin N 5 „ � � <br /> � ! I ' � (' g i � ` /s TYPE X GWB SHALL BE � .� <br /> GYPSUM WALLBOARD SCHEDULE ' xs ' INSULATE F�OOR OVER 19 APPLIED TO CEILING OF GARAGE � L <br /> i i � (' � � I D1 WHERE NABITABLE ROOMS ARE ' "_ <br /> /a GYPSUM WALLBOARD (GWB) SHALL BE �� 8 i � g UNHEATED SPACE g , , 8 ABOVE. MIN.Y2" GWB APPLIED TO 8 �„ <br /> 5 � � D1 D1 D1 ALL WALLS, BEAMS, AND POSTS D1 � <br /> USED THROUGHOUT ON INTERIOR WALLS, ----- ' <br /> INTERtOR SIDE OF EXTER(OR WALLS AND ,) D� _ ; W/D ; ' i i ' \ WITHlN GARAGE. � <br /> 1 D1 2 �' � �' I � '� LQW WALL j� � SIM. SIM. � z <br /> CEILINGS EXCEPT AT EXTERIOR WALLS AND � � I � +42" AFF � � � <br /> COMMON WALLS REQUIRED TO HAVE A 3-HR (� � � �� , , „ „ �� � � Garage � �- � <br /> OR 2-HR FIRE-RESISTANCE RATING IN � '� `�' �� -4" 2 -6 7'-8" 2'-6 1'-4 � � <br /> � WHICH CASE 5/a" TYPE 'X' GWB SHALL BE I I � 1 'I 1' ' <br /> Y2" GWB, INSULATE N a <br /> USED. '�; � � � �----�3-0 BIFOLD (� N I . . . -----..._-._----.----. .------- -- . , 1 UNDER STAIRS � � <br /> ''I 1.1� Bath � �ZZNxJO��( . 1� ' ^ I' . . . . . . . . . ! . . . . . . . 1�1 O � > i r r � i <br /> \ 15 ��� m o �' I ATTIC D1 �� � ( �..��.� � ,_��__ _-� _� 5'-8' 3-2' 6'-6' � <br /> , �-z I AGCESS� � ( SOFFiT AT 7--6 AFF � � <br /> � D3 � � � �n � �__� � ,1 19 I� N <br /> "' � �N 1 CONTINUE COMMON WALL D1 I N � <br /> LOCATE PLUMBING � � ° , ,� = � � GWB THROUGH FURRING � � � <br /> � � 18" TB � I �� I i `� i � <br /> ROUGH-IN ACCOUNTING � '1 -- � �� � TYPICAL pN � _ ' :' o., <br /> FOR SHEAR PANELING 1 � � � LOW WALL ,) LOW WALL �� , STEPS AS � I � � <br /> L- --- � .= � � <br /> � � > � AT +42 A.F.F. � � +42 A.F.F. ,� j <br /> RE RED <br /> AND (2) LAYERS GWB � ,� �' o ( " : 0 7 � <br /> _ `L G� W WOOD CAP � ; � � 9 3 � <br /> AT COMMON WALL i , � `� cn .� I � o, N �I � � li o� i D2 I------ � o O <br /> ,�j 5 SHOWER � �, , �, \ ;�, 3 7" �, <br /> ( � r,� d- I D2 D1 I __ 5 � � z <br /> ', il 3 1 � �� II . . 1, ' P I W �---- D5 , <br /> �, M. Bath = ,� �� D�ning � � , <br /> (' 2-4 HC I ; ,� N �, � �j• "i � .......... . � cc <br /> � 24" TB � I I � � .. .. .' -a <br /> � �t. "' 1 � LOW WALL � � �o � �., � ••S & P o� • � o � <br /> , °� ij .� ( RAISED FLOOR '� �, .- � � T � . _ . <br /> > +36 ABV. NQSING 1 � � � � N (' � N <br /> I; � � �n ' � 2-8" � 11 � '� ���C = ... ... 2-0 ( c r- <br /> � <br /> '� i l � � ; � D3 / `� �8" 16 �' BIFQLD �j '� 11 r► <br /> I ,r; <br /> . ; .- � <br /> � 2 ��- ---'--- ; " �; ; Kitchen �; i� N <br /> �� D1 � � 1 � 1 �1 I � �� 16 � 2 INSUL 20 MIN. N 1 D3 � � <br /> I RATED SELF 1 <br /> '; g'_3�2�� 3'-2" ��_2� � i8�2 1 �' i ^N il ^N �3 I' �� GLOSlNG `�' � � � � � a� o <br /> � <br /> ti » � i � '' 1 I ;\ UP i " � LOW WALL +42" 3'P7„ 1' � .. W Z Q N <br /> PLANT SHELF AT +36 A.F.F. /� <br /> � W/ LOW WALL BELOW m � � � �� � o � �� � �� ABV. NOSING �' W Q o <br /> ' o cn ' o I � � I �� � J <br /> � (i � � i o � ,i 'r' N �� 8 Den o �, a <br /> ' 'i � i' o � Ci � ° � Q � °� ,o�-oy2�� ; W W <br /> 0 <br /> �; Master ' ', ,� Nook , �ow wa�� , Entry � ., r � . <br /> 1 I 1 1 O � 3'-6" 2'-3" 3^2l2 3^�Q�2 � � � DING ABV. ; 3 i� � 0 T V <br /> ;� Bedroom � �, �� � o i� � LAN , 6 _ <br /> W <br /> j �4 \ � N j' r J � a <br /> �� � �� �, � ;� ,; ,_ � o, � ;f w ❑ � o 0 <br /> , � �...a�s.... ....�x$. ......� 1............. ... .. . .1� � r' <br /> ..........., ........... .............. : • <br /> . ... .. . <br /> � � ( � � DW � : 1-2 3-�0 FIXED � ^ � �-p 5�0 SH 3 ,5-0 SH � ■� W <br /> � � � � � ' !.___.� � 8'-� A.F.F. � �i OVE ABOVE � 6'-8" A.F.F. � �' 8» A.F.F. � Porch � <br /> , : . • : <br /> . e �'� EGRESS ... " 1 :.. ..: = <br /> N . . . .. . . C�! .. � . ---- -----I+-----) I � <br /> � � � 4'-9" 3'-6" I � ' <br /> ' . •�� 7-Q 5- DBL SL ' I 7-0 5- DBL SL 6 � 12 � i _ <br /> ( g � 7'-`� A.F.F. 4 6 � 8'-0"' A.F.F. D3 ' ' I 5 � <br /> � � ��_ D6 5'-10/g" 4y" � "' 6 � <br /> D4 ; , D3 D4 � 11 <br /> i 4'_4" 4_4" 1'-9�2 � -8�2 � , , � , » � \ _ i N � . <br /> , 4'-4" 4-4' 2'-4" 2-2 � <br /> 2'-2 g -g 4-g 2'-2" 8'-8" 4'-6» ! �� `- <br /> , L 15'-4" � � 1�= ---------- -J <br /> � <br /> P � <br /> 10'-0�4 4'-0" � <br /> 15'-4" � <br /> N O T E S � � <br /> FRAMING: 2x6's AT EXTERIOR WALLS THE FIREPLACE SNALL BE LISTED BY UL OR FM AND � � <br /> 2x4's AT INTERIOR WALLS SHALL BE INSTALLED IN ACCORDANCE WITH THAT U N [T E1 A E1 C E1 E MIDDLE LEVEL PLAN U N 1 T E1 A & E1 B LOWER LEVEL PLAN O � <br /> UNLESS NOTED OTHERWISE. LISTING U N 1 T E1 A E1 C & E1 E UPPER LEVEL PLAN � � <br /> SEE S1.1 FOR STUD SCHEDULE. .. � » � 1/4"=1'-0" 1/4"=1'-0" � � <br /> PROVIDE WATER RESISTANT GYPSUM WALLBOARD 1/4 =1 --0 � � <br /> •••••••••••••••••• R-21 BATT INSULATION BEHIND TUS AND SHOWER ENCLOSURE MATERIA�S � � � <br /> ------ 3�/z" ACOUST. 1NSUL EACH SIDE TO A HEiGHT OF 70" MINIMUM ABOVE THE W Q � U <br /> OF PARTY WALL, UNO. DRAIN INLET. `- ,' nt�"'�/ i " �) nt�"�/ ; � <br /> � ' � � C N <br /> CONCEALED SPACES SHALL BE FIRESTOPPED !N BQTH NO PLUMBIN�, MECHANICAL EQUlPMENT, DUCTS OR ,� � � �I I� 6 � � <br /> DIRECTIONS AT 10'-0" ON CENTER AND AT FLOORS. VENTS SNALL BE LOCATED IN THE COMMON UNIT � D4 \ � � �' Ij D4 \ � � j' Q � y � <br /> TYPICAL SEPARATION WALLS PER IRC SEC. R302.2 (EXCEP�'ION) I /_ � p� �o i i /^ � �1 o i - � <br /> 0 <br /> �, J � � .� <br /> ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPfNG ALL BEDROOM AND BATHROOM DOORS SHALL BE �•••.••.•.•••• •.• ••••••�• � •�� I�••••••••�•••• ••• • •��••••� • •�� <br /> ROOMS SHALL HAVE A MINIMUM NET CLEAR OPENING UNDERCUT A MINIMUM OF 3/4" ABOVE TME ADJACENT �-0 5-0 SH 3- 5-0 SH ( �-0 5-0 SH 3-0 5-Q SH o F- t � = GJ O <br /> OF 5.7 SQUARE FEET. THE MINiMUM CLEAR OPENWG FLOOR COVERWG. � c� 6'-8" A.F.F. � 6�' 8" A.F.F. j Porch � � � 6'-8" A.F.F. � 6`-8" A.F.F. I o�o �■/ � i. <br /> HEIGHT DIMENSION SHALL BE 24". THE MINfMUM CLEAR I �� � Z <br /> �-------- ---� �----------------� <br /> OPENING WIDTH DIMENSION SHALL BE 20". SILL THE FRONT DOOR SNALL BE OPENABLE FRQM THE : � T ' � _� W � W � <br /> HEIGHT SHALL BE NOT MORE THAN 44" ABOVE THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL � � I D6 6'-3" \ D6 �� <br /> FLOOR PER IRC SEC. R310.1.1. KNOWLEDGE OR EFFORT. IT MAY BE PRQV1DED WITH A � ;j, � _ � � .- Double Porch °� °-�� � � <br /> NIGHT LATCH, DEAD BOLT OR SECURlTY CHAIN, � �- \ � � �\ � � <br /> WHERE SILL AT OPERABLE WINDOW IS LOCATED MORE PROVIDED SUCN DEVIGES ARE OPENABLE FROM THE � <br /> THAN 72 INCHES ABOVE FINISHED GRADE OR OTHER INSIDE WITHOUT THE USE OF A KEY OR TOOL, AND � � �E------- � - � � - � � � <br /> SURFACE BELOW, SILL NEIGHT SHALL BE MINIMUM 24 MOUNTED NOT TO EXCEED 48 ABOVE TNE FINISHED � � <br /> � <br /> INCHES ABOVE FINISHED FLOQR. PER IRC SEG 312.21. FLOOft. � � �_ �___ _____� '�- �---------------�- --- -- ' O Q. <br /> � <br /> ALL GLAZING SHALL CONFORM TO IRC SEC. R308.4, STAfR NOTES: P � 1' 1%g" 9'-7%g" 4'-0" 9" � <br /> HAZARDOUS LOCATIONS. GLAZING IN A�L DOORS SHALL LOCATE HANDRAILS AT 34'-38" ABOVE THE g�_�3�8» ��_�5�g�� <br /> BE SAFETY GLAZED. ALL GLAZING WITHIN A 24" ARC STAIR NOSING. 15-6" Q <br /> OF EITHER VERTICAL DOOR EDGE SHALL BE SAFETY 10'-1" 4'-0" <br /> GLAZED. ALL GLAZING WITHIN 60" OF A HAZARDOUS HANDRAIL GRASP DIMENSlON SNALL BE BETWEEN 1" & 15'-4" � �, <br /> LOCATION, OR "WET SURFACE" SNALL BE SAFETY 1-1/4". PROVIDE CONTlNUOUS HANDRAIL OR � 1ob No.: 13-47 <br /> GLAZED. TERMINATE SEE U17 FOR INTERIOR ELEVATIONS U N IT E1 E & E1 F LOWER LEVEL PLAN U N IT E1C & D LOWER LEVEL PLAN � <br /> � <br /> AT NEWEL POSTS OR SAFETY TERMlNAL. - Sheet No.: ' <br /> PROVIDE 5/a" (MIN.) GYPSUM SHEATHING ON 1�4"=1'-0" 1/4"=1'-�" � <br /> WALLS BEHIND TUB/SHOWERS TO SATISFY FIRE WHERE USED AS A GUARDRAIL, A MAX. OPENING OF i AND INTERIOR STAIR PLANS � � <br /> REQUIREMENTS AT UNIT SEPARATION WALLS CONDITION. 4��. E S D I .� <br /> Sheet Order: A � U F R <br /> _ <br />