J �
<br /> GE N E RA L N O T E S WD. L�DGER & RAI L GAP
<br /> TO MATGH �XIST. ,., ,
<br /> ��
<br /> N AT TH� 2x2 WD. GUARDRAIL ``\ ��-, ` ,,,-'��// ��
<br /> I. DO NOT SGALE DRAWINGS. GONTRAGTOR TO VERIFY DIMEN510 5 ,, � �r�.
<br /> SITE. PIGKETS TO MATGH �X15T, �-, ` /,,,-
<br /> 2. VERI�Y ALL DIMEN510N5 IN THE �IELD. NOTI�Y ARGHITEGT O� ANY �V�NLY SPAGED; 6UARD5 � `` ',,, � '��
<br /> SHALL NOT ALLOW PA55AGE a a � ' �"? ry
<br /> DISGREP,4NGIE5 DISGOVERED BETWEEN THE DRAWINGS & AGTUAL �� �T�, EX15T. VAULTED -��� � .
<br /> GONDITIONS BEFORE PROGEEDING. VERI�Y EXAGT DIM�NSION O� PRE- O� 4 DIA. SPHER� � �,,� ,,-� \
<br /> �ABRIGAT�D GOMPONENTS IN THE �IELD. GL'G, TYP. , � A`
<br /> z � -v � EXIST. ���, ',�� �� EXIST.
<br /> SHEET METAL GAP
<br /> 3. ALL WORK SHALL GON�ORM TO THE 2015 INTERNATIONAL RE5IDENTIAL � -� v S.L. r-_,` ,,, S.L. ��
<br /> „ � / , EX15T. .�- �� EX15T. TRAN50M L °
<br /> GODE W/ WA5HI�IGTON STATE AMENDM�NTS � THE 2015 WASHINGTON STAT� O 4 DRAIN GHANNEL W/ 20 � 0 OPEN TO � � �� S1-� ��� WINDOW '�
<br /> ENER6Y GODE. c� 6A. SHT. MTL. �LASHING; � '�
<br /> 4. ALL EXTERIOR DIMEN510N5 t�RE TO THE �AGE O� GONGRET�, STRUGTURAL EXTEND UP 51DE & TOP O� � z STAIR � D�MO PORTIO
<br /> MASONRY (NOT INGLUDING V�NEERS) OR WOOD �RAMING (NOT INGLUDING �AGIA BOARD X � O� E X I S T. EXTEND
<br /> SHEATHING) UNLE55 NOTED OTHERWISE. WALL
<br /> 5. DIMEN510N5 TO �LOORS ON SEGTION � ELEVATIONS DRAWINGS f�RE TO TRA��IG MEMBRANE OVER � � PARTITION WALL �RM,G OP�N ADJ. WALL GAP o
<br /> EXP05E EX15T. BAGK- SHELVES
<br /> THE TOP OF 5U8-FLOOR OR DEGKING AT WD. �RAME GONSTRUGTION, TOP 6�� %2" ?�G PLYWD. OVER EXIST. ______ TO GL'G SPANNED ENTRY BE�LM �
<br /> O� GONGR�TE AT GONGRETE GONSTRUGTION � TOP O� STEEL �RAMING AT 2x T�G SHEATHING; EXT�ND ------ --------------------'---------"-'--------------" -
<br /> a�
<br /> MEMBRAN� UP 51DE # TOP �'
<br /> STEEL GONSTRUGTION, UNLE55 NOTED OTHERWISE. DEGK � � � � ` ` �
<br /> OF FAGIA BOARD
<br /> SURFAG� i9 V�RI�Y N�W UPPER ��w �� � �
<br /> HIGH PT. VERI�Y w EXIST. BM. � - EXIST. GABINETS, TYP. w���- i
<br /> M . 2% SL. = EXP05E EX15T. Bt�GK-
<br /> BEARING TO � � WIN. � � i i FRA ING � �
<br /> � REMAIN � SPANNED ENTRY BE�M P TRY �
<br /> � � `� OPEN TO STAIR-� WALL GAP NEW PLAM.
<br /> F L O O R P LA N N O T E S m z � ----- z _ � GOUNT�RTOP, Np. �
<br /> - � ----SL= ��� O _
<br /> � z �� ~ � o 0 0 o IDOUBLE-BA51N N�W TILE BAGK- o
<br /> � I � 51NK � SPLASH, TYP. N
<br /> I. ALL INTERIOR PARTITIONS TO BE 2x4 �RAMING, U.N.O. OR �OR �ULL � � EXIST. 4x Q � � � ` ------ ------ o
<br /> GOVERAGE UNDER BEAM WIDER THAN 3S". ALL EXTERIOR INFILL GANT � - � � � � � 0 �
<br /> RA�TER TAILS
<br /> FRAMING TO BE 2x FRAMIN6 TO MATGH EXISTING. � � � NEW BASE � � M
<br /> 2. �OR WINDOWS ff DOOR 51ZE5, SEE �LOOR PLANS. `� m � � � GABINETS, TYP. WD. BA `r'
<br /> GONN�GT PIGK�T TO �XIST. �AGIA X � � � � � �
<br /> 3. INSTALL AGOUSTIGAL INSULATION AROUND PERIMETER WALLS O� ALL BOARD W/ MIN. (2) 3" DEGK SGREWS EA.; DRAIN W/ 2" w I �
<br /> BATHROOMS. �
<br /> 4. 5EE INTERIOR ELE�/ATIONS, 6ENERAL NOTES, �R,4MIN6 NOTES, AND B�v�L BOT. O� PIGK�T TO MATGH EX15T. ,4B5 DRAIN �A. �
<br /> SLOPE TO I'_3" 2'_6" I'_3" b�� 3�_0�� 2�_��� 3�_8�� �I'_2" �I'_2" � 2'_8" � 3'_l" � N�W 36" EXT. DOOR ,� �,
<br /> SPEGI�IGATIONS �OR ADDITIONAL I�1�ORMATION. �ND% WD. BAS� �`� ��r �� TO ROOF DEGK V
<br /> REPLAG� FAGIA IF ANY DEGAY 15 D.S. C� BLDG. �LEG. RANG D.W. DWR RE�. 42 P,4NTRY �n
<br /> DISGOVER�D; FAGIP� SHOULD �E NAILED GORNER; FAINT DNDR�T O�/EN GABINETS 0 W �
<br /> TO DEGKING W/ Ibd � 12" O.G. AND (2) �INISH � � �
<br /> Ibd � EA. RA�T�R �ND ��� r,-,
<br /> O`� �i �n
<br /> SYMB�L LEGEND � 3 ROOF DECK GUARDRAIL _ 9 KITCHEN ELE�ATIONS ❑��
<br /> � �
<br /> 1 2 - 1 -0 EAST SOUTH WEST $" = 1'-0" � �� � U �
<br /> � r� N
<br /> c� � �
<br /> DRAFTIN6 SY1�OL5:
<br /> � WOOD FRAMING � �
<br /> ''� �
<br /> NO. BUILDING SEGTION � SHIM OR BLOGKING �
<br /> � �
<br /> SHT. � PLYWOOD � `�
<br /> �
<br /> �
<br /> � FINISH WODD o
<br /> a�
<br /> NO. WALL SEGTION O EXISTING M,4TERIAL
<br /> � '
<br /> SHT.
<br /> � STUGGO ON LATH �
<br /> �
<br /> NO. D�TAIL INDIGATOR � 6WB OR GYP. SHEATHING
<br /> M
<br /> O
<br /> SHT. SEGTION � PARTIGLE / WAF�R BD. N
<br /> a�
<br /> �
<br /> � BRIGK / MA50NRY
<br /> .�
<br /> �
<br /> u�� ���1 D�TAIL INDIGATOR �"'� �`���
<br /> �
<br /> a�
<br /> SHT. ��� PLAN NEW WOOD STUD WALL; �
<br /> 2X4 � I6" O.G. W/ I/2" �
<br /> G.W.B. BOTH 51DE5, U.N.O.
<br /> w
<br /> NO. INTERIOR ELEVATION � GMU WALL 39N�10 n0'� °�
<br /> SHT. INDIGATOR �SIy�� ��NbN�
<br /> � BRIGK WALL OR VENEER EXIST. DEGK �
<br /> �
<br /> WD.
<br /> 0 GONGRETE WALL
<br /> �
<br /> u� REVISION INDIGATOR
<br /> EXIST. WALL TO REMAIN
<br /> � �
<br /> cu
<br /> '�___________1 EXIST. WALL TO BE _ _ _ _ _ _ _ _ _ - - - � �
<br /> NO. S��N��SAHORS���T REMOVED ► �X15T. WIN. WASH - � �
<br /> EDGE O� EXIST. �
<br /> PARTITION TYPE SWING DOOR; ADJUST EXIST. � R�. ABV., TYP. PLATFORM BELOW �
<br /> STAIR GUARD WHERE �
<br /> INDIGATOR - SEE (R) = R�PLAGED � GON�LIGTS W/ NEW (R) I6°6a SLIDIN6 DOOR PAIR I �
<br />' PARTITION SGH�DULE I
<br /> SLIDIN6 DOOR; DEGK 6UARD I �
<br /> � (R) - R�PLAGED I NEW BUILT-IN AN GAB. �`
<br /> � BOOKSHELVES �
<br /> �NO HANGER GONNEGTION 15 ° z I �
<br /> SGHEDULE � WINDOW; (R) = R�PL�tGED DN I ' o
<br /> - • - • - BEAM OR HEADER ABOVE w • I � . O I �
<br /> ai
<br /> O WINDOW SGHEDULE � W � R RBISH IST. I ' �
<br /> FRAMING ABOVE MA �.P. w I
<br /> O `�
<br /> X DOOR SGHEDULE - • - • � BEAM OR JOIST HANGER �IEW WD. GftTE w � � � � l,
<br /> N�W 36 H. EXIST. GPT. � i
<br /> 6UARDRAIL LINE OF EXIST. GARAGE� I I C� � I `� "- °' °' °'
<br /> � WALLS BELOW, TYP. � F- p I N c 4- � •�-
<br /> o,.� .r o �.
<br /> �' - -------- - - - I y - `n . I �'-�- � � �, 3 °
<br /> __-_- _ __� ��������_��_____ _ ____T_________T .
<br /> '�� � --------- - ----------------- - - -----�--- ------�� - Ix��� -� EX15T. GPT. � � a�i c =' �
<br /> �i-�\Q i i � Z l�� EXIST. HDWD. � � a-o �s a,'
<br /> I � � V�R IST. R. ' W/ p- c ° °� � �
<br /> NEW R.D. 8 ¢ i i E MAI T I � i E EXI T. PAN�LIN n-�- m '� vi I � c � � o m
<br /> DOWNSPOUT i i D O U B E W, I p � WALL , R�PL } � . '."f � -° v�i � � a L
<br /> ; ; � �n � W B, P I N T E D �I N I S H, T Y P. � v � �
<br /> d � m �no � .r
<br /> � � � ZQ � � i�'�% ��. wD. � � � � o
<br /> ; ; RUN NEW MEMBRAN� UNDER tY I & > ��`=-' I �° � c�i o o �
<br /> � � EX15T. 51DING FLASH'G � NEW I � � RIDG BM. A ~ T���_ I � � � •� c o
<br /> c� �.w,
<br /> � � DOOR THRESHOLD �LASH'6 I � I PHON� � � � � � N
<br /> � � I W I I � c� o � L •L
<br /> X
<br /> I � ..�. � (0 � L
<br /> _ _ _ _ _ _ _ _ _ _ � _ � 13 , � EMOVE EXIST. ROO�ING DOWN TO � _ . - _ _ � � �
<br /> � DEMO PORTION OF EXT. � � o EGKING, GOV�R W/ N�W TRAF�IG ASOVE GOUNTER; ,n o � � c �
<br /> -o a u� .. n c
<br /> EXP05E NEW �ULL-HT. �RAMED � U o � �,
<br /> ���� WALL FOR NEW DOOR P'2�1 � EMBRl�NE OVER 2" AG PLYWOOD; I > I EXIST. BAGK-SPANNED WALL EXTENSION TO I � Q � o �
<br /> I , EX15T. EXP. POST , Cp I�I �� F- ._
<br /> � RIDGE BM. ABV. ; M?�INTAIN EXIST. ROO� SLOPE I Q ��� o� E N T R Y B M. G E I L I N G; V E R I�Y �X15T.
<br /> �I� -
<br /> ;�', DEMO EX15T. DOOR ; , � � BEARING FOR EX15T. i�
<br /> �I� � � z I � GPT. �
<br />� ,�,� � 6A�F RDOF D�GK � I�I ENTRY BM. BELOW �
<br /> NEW PARTIAL HT.
<br /> , GAP OR RELOGATE , , FRA W�t
<br /> ��_________� L�--�--- z BOOKSHEL� � i o NEW MEMBRANE � `p I I' m BOOKSHEL� G���A� ���
<br /> EX15T. LAUND. PLMB G O
<br /> �� I ; LINES AS NEGESSARY �� �� p GOATS , , z _ DN. . TS:, STOR.
<br /> � . , ! �/ERI�Y �X15T. � 3-6 GLR.
<br /> ' j ' KITGF�N I'�_-1=__a i i 29'o SLOPE, TYP. IN�ILL I � � ---------B- I � �
<br /> � I � EXIST. HDWD. TD � �-- -I ;I.' ; EX15T. � z Q --------------� -_-�;
<br /> --� ;'�, BE REMO�/ED ; ; I ;II' � � DOOR � Q v MIGRO I t�I . N.S. � -
<br /> � � \ �---- f- � I � � ;I,I �n � �n � � W DRAIN GHANNEL � X � � �BELO � y � Q�
<br /> DEMO OR I ,,''�� � � �� � � �' � , - - � I � Q - � i- z
<br /> �ST SIDE ONLY W/ w I
<br /> R�LOGAT� �%'� � -t---, ' � I '�1-- '--;�I� w v w v ' � ROO� DRAINS c� q x I � ~ p-- z Q � �
<br /> , � -=+---a � z v O � I �
<br /> EX15T. � � --�,•�� , i i � �,� p i i RTH B SOUTH ENDS INFILL ( W I I z ►li• � � Q
<br /> WALL HTR. ' ' � I I I►- � ,�I,----j--,���,I; z i i ° EXWIN. � I A 2.1 _ I� I � j O O I I� I EX1�5 R T.�G�P T. �
<br /> � EX15T. �/INYL i ;r-�-� � ��,_,,,,-,,�„ " � � M
<br /> ; TO B� �, ; � '�� I X � I �'�`__���-�;��� I
<br /> ,�, �, REMOV�D I I� � '''' Lw �n J II�"'�I�"'�III I��- DEMO PORTION ; ; I �� o Lw�� Q � O O I l� DN. ��� O
<br /> I�; I �, ;I � '�'� ��`�_��`�_��� O� PART. WALL � � W INDO W & D O O R I N�I L L N OT E: EXT. NEW HDWD. TO p� o EX15T. HDYVD. � N
<br /> �
<br /> ' ' " " ' '' ' I I MATGH EXIST. p
<br /> �I J � I� ,� ' ' ' i i A�V. GOUNTER i i SHEATHIN6 � SIDING TO MATGH _ I �� � z � � � �
<br /> �� � � , � � - �I�
<br />� , ��Y , , �X I S T. O V'E R W.R.B. O V�R 2 x 4 I I m Y I N Y L � � V � �
<br /> , �, �-_-�-�_--� , � �
<br /> J ",L---{ � J j '�' � � 5TUD5 � I6" O.G. W/ BATT INSUL.� D.W. - X m N.S. � � CQ O
<br /> � DEMO ;°�, `. ,i �r �, � � � EX15T. � � � � I I -
<br /> \� �� �� �� �. �� fiDWD � I INT. � G.W.B. TO MATGH �XIST. I I � - - - -I I '' O w ~ � � O �
<br /> EXIST. WIN. I I , ;' ' " ' '; ;� �°
<br /> ', ; � ;'--�`---�� � � � I � _� � � �
<br /> `-----__--_1 I IL_____r____________________________________r___�_________�J
<br /> ____________y___1_________1 '�
<br /> D�MO LAUND. EXIST. WIN. ----�;-�-----y----------------------- I �X15T. WIN. � C�..) �
<br /> �� REMOVE �X15T. � �XIST. WIN. WASH - � � � �
<br /> WALLS, KITGHEN I I I. I ( I �+4� NEW 36" H. � I I I PANELING ON WALLS, � PLAT�ORM BELOW � �
<br /> GABINETS � APPL'S I I I I I I NEW R.D. � � GUARDRtkIL REPLAGE W/ NEW GWB, � �
<br /> I I I I I DOWNSPOUT I I I pAINTED FIN15H, TYP. I - - - J (n z �
<br /> EDGE O� �XIST. I�I - - - - - � I�I 13 EX15T. GARAGE ROOF EAVE; ICI - - - - - -� ��I � N �
<br /> GARAGE ROOF BELOW GONTINUE N�W TRA��IG I u LINE O� EX15T. RF. u I � >
<br /> I U LINE OF �XIST. RF. U I f'`2�1 MEMBRANE TO ROO� EDGE LINE � SM5 ABOVE � �t' W
<br /> LINE � BM5 ABOVE
<br />� �- - - - - - - - - J SIM.
<br /> N N
<br /> PARTIAL DEMO UPPER FLOOR PLAN PROPOSED UPPER FLOOR PLAN A-2 . �
<br /> 1" = 1'-0" ��� = 1'-0"
<br /> 4 4
<br /> ❑
<br />
|