Laserfiche WebLink
2x4 RAIL AND CAP <br /> �s" MIN. TO TOP 2x2 PICKETS SO THAT Pf2SCt'IptIV@ Et12t'gy COd2 Compliance for All Ciimate Zones in Washington. <br /> OF CAP A 4° SPHERE 14'-0" <br /> USE 1"x1" MTL FLASHING HERE, AL.SO �AY NaT Pass r�Ru VARIES SEE PLAN All Climate Zones <br /> EXTEND BLDG PAPER BEHIND LEDGER SECURE W/ (3} i6d GALV. 4x4 RAIL 2'-0" 10'-0" '-0" a a <br /> 2x4»2x6, OR 5/4x4 OR TO RESfST 20# /LF LOAD POSTS TYP R-Value R-Va{ue �--�_--�_.,� <br /> 3/4 PLY W/N+EATHERPROOF (6 O.C: MAX) VARIES SEE P�AN b --.� <br /> MEMBRANE NOTE: RAILING NOT REQ. Fenestration U-Factor n�a -Q�� �.�� ) <br /> ON DECKS W IN .� <br /> • D CK JOISTS PER PLAN 30" OF FINIS ED GRADE Skylight U-Factor f1�a 0.50 <br /> ' W MTL HANGER BRACKETS ., <br /> N1-H5 CUP EA JST 2x RIM J41ST o Glazed Fenestration SHGC b�e n�a n�a <br /> DBL DTT2Z TO BEAM SOLID BLOCKING END POST � � 4x12 P.T. BEAM � N Ceiling 49���""� 0.026 <br /> (NSTALLED 2x LEDGER WiTti �- BEAM PER PLAN � � tv - - � k,l � <br /> W/ALL-TNREAD 3/8°x4" GALV CONNEC110N TO COL. d- � � � � Q Waod Frame WQ�� 9' 21 It�t �. �-� �> �.�5� <br /> LAG BOLTS W/WASHERS 2x4 CLEAT BOTH SIDES <br /> . -o � �- Mass Wal1 R-Value ' 21 21 0.056 <br /> � 16' O.G STAGGERED OR SIMPSON POST CAP � .. � �`� " <br /> � (2) � EACH END -+ � m � � n .�i <br /> � COLUMN PER PLAN � o � o o � � Floor 309J O.Q29 <br /> N PROVIDE KNEE BRAGES o an ^^ �� c,k � +� I•'�� <br /> i � Below Grade Wall 10/15/21 int + TB� 0.042 <br /> �. FQR LATERAL RESISTANCE � zo � �v � ��� � � Q Slab R-Value 8c Depth ��, 2 ft 11�4 <br /> � iF COLUMN EXCEEDS 4'-0° HT. MID POST M �c� --� a -o ' --r o -o � � d <br /> � <br /> J � rv c�n�y o iv cn r i � <br /> D N � t7 N� D = <br /> �^ M��. BLOCK (SANDWICH) C4 c� � m � � rn For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .-. intermediate framing. <br /> GRADE POST & THRU-BOLT -� LINE OF HOUSE 'a � , 2x8 P.T. LEDGER `'� � o �`� �a.�-values are minimums. U-factors and SHGC are maximums. When insulat+on is installed in a covity which is less than <br /> NOTE:. - � -'�athe lat.�e) or design thickness of the insulation, the compressed R-value of the insulation from Appendix Tabie A101.4 <br /> 51MP50N STEEL POST BASE USING GALV 3f8" CARRIAGE � <br /> ALL WOOD EXPOSED TO N� a � iNSTALL PER MFGS SPECS. shall not�be less than the R-value specified in the table. <br /> WEATHER TO BE PRESS. TRTD � • ��° BOLTS WITH WASHERS NUTS ,//u� b. The fenestration U-factor column excludes skyiights. The SHGC column app�ies to oll glazed fenestration. <br /> OR HAVE NATURAL RESISTANCE � CONCRETE FOOTING 4 x 4 P�S T [�E TA� L �- ��I� Exception:��Skylights may be excluded from glazed fenestration SHGC requirements in Climate Zones 1 through 3 where <br /> TO DECAY PER FDN. PLAN � ,�- � the SHGC �or such skyiights does not exceed 0.30. <br /> D E C K D E TA I L �� _ � �� _ � �`}�� c. °10/15�21.+1B" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on <br /> SCALE: 3/8 � - � LI N E 0 F H 0 U SE TYP f C A l�/� V'�' n� the int�ior of the.wall, or R-21 cavify insulation plus a tfiermal break between the slab and the basement wall at the <br /> � g (�,� 1" inter�r of the basem-�nt wall. "10/15/21.+TB" shall be permitted to be met with.R-13 cavity insuiation on the interior of the <br /> � WNERE APPLICAB�E " ' " SCALE: � 4" = 1 �- O�� '� <br /> SCALE: 3/8 = 1 - Q / r �i'�"" � baseme,�t wall plus R-5 continuous insulation on the interior or exterior of fhe wall. °SO/13" means R-10 continuous <br /> . WSTALL /2 SIMPSON DTT2Z DECK TENSION TIES PER D E � I� P L.A N �ti� Ai� �� insulatio on the interior or exterior of fhe home or R-t3 cavity insulation at fhe interior of the basement wall. "iB° means <br /> \ � �� s J �tj thermal�break be#ween floor stab and bosement wall. <br /> DECK (DECKS UNDER 30" ABOVE GRADE ARE EXEMPT) /' �� �l/, d. R-1�0 continuous insufation is required under heated slab on grade floors. See R402.2.9.1. <br /> � ��v� �� e. Th�re are no SNGC requiremenfs in the Marine Zone. <br /> ' ��1 f. Basement wall insulation is no# required in warm-humid locations as defined by Figure R301.1 and Toble R301.1, <br /> 5 FT S E TB��K S FI R E- R A TI N G _ ����'� ��• hj�F"rstrvo ue is cavit insulation second is continuo s ' <br /> /',�'� �� y , u insulation or �nsulated siding, so 13.+5 means R-13 cavity <br /> M1507.3 Whole-house rneChaniCaf verltilation system. Whole-house meChat�lCa( V" /�� � insulation pius R-5 continuous insulation or insulated siding. If structural sheathing covers 40 percent or less of the <br /> ventilation systems shall be designed ir; accordctnce with Sections M1507.3 1 through L�,�jG� �,�/ exterior, continuous insulotion R-value shall be permitted to be reduced by no more than R-3 in the bcations where <br /> MAXiMUM 18" ENCROACHMENT M1507.3.3. � ✓ �'� � structural sheathing is used to maintain a consistent fotal sheathing thickness. <br /> (INCLUDING EAVE OR OVERHANG) i. The second R-value applies when more tha� half the insulation is on the interior of the mass wall. <br /> M1507.3.1 System design. The whole-house ventilation s stem shall consist of�one'"r <br /> Y j. For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R-38. <br /> . more supply or exhaust fans, or a combination of Such, and assOciated dUCtS and - k. Int. (inte�mediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of <br /> NO ROOF./ATTIC VENTI�ATION contrals. �ocql exhaust or supply fqns are permitted to serve as such a system. R-10 insulation. <br /> Outdoor ai� duCts connected to the return side of an air handier Shall be CorlSideCed �• Log and solid timber walls with a minimum average thickness of 3.5 inches are exempt from #his insulation requirement. <br /> to provide suppfy ventitation. <br /> 1 HR CONSTRUCTION AT WA�LS M1507.3.2 System controls. The whole-house mechanica3 ventilation system shall be Building Air Lea.kage Test_ina <br /> (5/8" GWB INTERIOR AND provided with controls that enable manuaf override. 201�Washington Sta#e Energy Code (WSEC) section R402.4.1.2 requires air leakoge testing for aH new <br /> 5/8" GYPBOARD EXTER�OR} houses and additions. The requirement is met if the structure has n {eakage rate of 5 air changes per hour <br /> M1507.3.3 Mechanical ventilation rate. The wholehouse mechanicaf ventilation system when depressurized with a blower door to 50 Pascals or less (5ACH�). A Poscal is a measurement of pressure. <br /> shall provide outdoor air at a continuous rate of not less than t�iat determined in 249 Pascals are equa{ to 1?of wnter column. The test must be performed using a Blower poor device which <br /> acCordance With Table M15fl7.3.3�1�. consists of a large fan, a frame and panei. A anometer (pressure gauge) is used to read house and fan <br /> Exception: The whole-house mechanical ventilation system is permitted pressures, <br /> F�RE RATED PLY UNDER to operate intermittently where the system hcts Controls that enqb{e WSEC states that the test moy be performed at any time after rough in. All penetrations in the building <br /> operation for not less than 25-percent of each 4--hour se ment and the <br /> g envelope must be sealed including those for utilities, plumbing, electrical, ventilation and combustion <br /> ventilation rate prescribed in Table M1507.3.3(1) is mu{tiplied by the factor appliances. The code also states that when required by the building afficial, the test shall be conducted by an <br /> . B U M P 0 U TS TH.A T P R 0 JE C T determ�ned in accordance with Table M1507.3.3(2). approved fhird party. <br /> 3�$"=�'-O" CL.OSER THAN 5' TO PROP LINE <br /> To conduct the test: <br /> ROOFING PER PLAN 1. Close ail windows, doors and fireplace and sfove doors. <br /> (PER STNp DETAIL) 2. Close ali dampers inc(uding exhaust, intake, make-up oir, backdraft, and flue dampers. Since you will <br /> TABLE M15Q7.3.3(1) be depressurizing the house, dampers in both fans, etc. will be sucked closed during tf�e test and will <br /> COR-A-VENT OR EQUIV "IN-VENT" CONTINUOUS WHOLE-HOUSE MECHANICAL VEN1I�.ATfON SYSTEM AIRFLOW RATE REQUIREMENTS therefore not negatively affect the results: <br /> ROOF fNTAKE VENT STRIP INSTALLED 3. Make sure plumbing traps are filled with water. <br /> 36' FROM EDGE OF EAVE (CUT 1" DW�LLWG UNIT � NUMBER OF BEDROOMS 4. Leave doors between heated qreas o en. <br /> WIDE STRIP IN PLYWOOD � VENT) FLOOR AREA 0-1 2-3 4-5 6-7 > 7 5. Open access hatches to conditioned attics and/or conditioned crawf spaces. Leove hatches cfosed if <br /> SOLID BLOCK, CUT TO FfT TIGHT (square feet) Airflow in CFM these are unconditioned areos. <br /> AGAINST TOP PLATE & SHEATHING < 1,500 30 45 6Q 75 gp 6. Seal exterior openings for continuously vperating ventilation systems and heat recovery ventilators. <br /> W/(4) 8d NAILS EACH BLOCK 1,501-3,000 45 60 75 90 105 7• Turn off heating and eooling systems but do not seal supply or retum registers. <br /> N0 VENTS ALLOWED IN BLOCK 8. Adjust a(I combustion appliances so that they do not turn on.during the test. <br /> 2012 IRC - TABLE R302.1(1) 3,001-4,500 60 75 90 105 120 9. Install the blower door in an exterior doar opening and connect hoses from the manometer to the <br /> blower door fan and the exterior ressure ta See rr��nu�Ea'atr�harctions for correct set-u " <br /> 4,501-6.000 75 90 105 120 135 P P� p• <br /> , ��0 INSUL PER WSEC 10. Depressurize the house to -5Q Pascals. <br /> 6,001-7,500 90 105 920 135 150 11. Record the flow rate (with simple manometers, the fan pressure (Pa) is converted �o+:�rl,dj a <br /> ' > 7,500 100 12d 135 150 165 flow table. Many digital manometers sold with blvwer doors can automatically perform this <br /> NQTE: WHEN REPLACENG For SI: 1 square foot = O.Q929 m2, t cubic foot per minute = 0.0004719 m3 s. conversion, and dispfa3n Qfif�ctly.) Consuit your blower door and manometar manuals. <br /> STANDART BIRDBLOCKS <br /> WITH COR-A-VENT TABLE M1507.3.3(2) You now must convert the flow rate (CFhlo) to ACHso. Use the follawing formula: <br /> PER PLAN OR AN EQUIVALENT, INTERMIT?ENT WHOLE-HOUSE MECHANlCAL VENTILATfON RATE FACTORS°'b <br /> USE A 10 SQ IN ACH50 = (CFM50 X 60) / Volume <br /> PER FT EXCHANGE RUN-TIME PERCENTAGE IN EACH 4-HQUR 25�. 50% 66% 75% 100% <br /> SEGMENT 33� <br /> Where: ACH50=Air Chan es er Hour at -50 Pascals <br /> 9 P <br /> Factora 4 3 2 1.5 1.3 1.0 CFM50 X 60 = Converts Cubic Feet per Minute to Cubic Feet per Hour <br /> TRU S S �e E A VE D E TA 1 L a. For ventilation system run time values 6etween those given, the factors are permitted to be determined by interpolation. Volume = Conditioned floor area of the housing unit muitip[ied by the ceiling height <br /> 3/8��=��-��� EAVES CLOSER THAN 5' TO PROP LINE b. Extropoiation beyond the table is prof�ibited. <br /> Example; A ulower door test has been done on a 2,000 square foot house and the fan flow (CFM5Q) rate <br /> is 1100 CFM. <br /> FIRE RESISTAN? RATED PLYWOOD ADDITIONAL WSEC NOTES: � C,L�.C„� <br /> � � O.H. IF GABLE END VENT IS �� � ACH50 = (CFM50 X &0) / Volume <br /> INSTALLED IRC 302.1(b) 1. 75� OF ALL INSTALLED LIGHTING IS TO BE HIGH--�EFFIC-IEN�,Y: ACH50 = (i100 X 60) / (2000 X 8) <br /> ROOFlNG PER PLAN 2. A PROGRAMMABLE THERMOSTAT MUST �E lNSTALLED. <br /> 3. A DUCT SEALING AFFIDAVIT MUST BE SUPPUED (1+�/HERE APPLICABLE) acHSo = ss,000/�s,000 <br /> 4. DOOR BLOWER TESTING IS REQUIRED (PER 502.4.5) ACH50 = 4.� <br /> PRE-MFG TRUSSES 5: AN ENERGY CODE CO�IPLINACE CERTlFICI�TE IS TO BE POSTED <br /> WfTHIN 3 FEET OF THE ELECTRICAL PANEL (PER 1Q5.�I-� Since the code requires the ACH� to be (ess than 5, this house complies with an A�,lof 4.1. Recocd.the <br /> SIDING IN UL PER W C ALSO: ACN so on the energy certificate on or near the electrical panel. " <br /> PER PLAN �. AN 1NSULATION CERTIFICATE IS REQUIRED FROM THE (NSTALLER, e y gy g publication contains material written - <br /> ? 2010 Washin ton State Universit Extensior�E�er Pro ram. This <br /> 2. NON-FULL WIDTH HEADERS ARE TO BE INSULATED TO FULL DEPTH. and produced for public distribution. Permission to copy or disseminate al) or port of this material ' <br /> is granted,provided that the copies ore not made or distributed far commercial advantage, and that each � "" <br /> 5' FROM PROPERTY LWE J7. NO HEATINC/COOL.iNG STACKS IN EXTERIOR WALL CAVITIES. 'S�ef�e"�� by t't'e w�th aed�t t° the "'°Sh�,9t°° St°te���ve�s�ty EXte°S�°�E��-9Y P�o9�am. ����9, • ; <br /> TYPICAL WALL reprinting or dissemination, electronic or otherwise, for pny other use requires prior writien permission Date �� ',.�°�'�{°"� <br /> PER P�AN 4. HEATING/COOLING DUCTS IN FLOOR/WALL/CEILING AREAS MAY NOT fram the Washin9ton State University Extension Energy Program.WSUEEP 10-0�t Rev. ,, 20,0 � � <br /> , iNsu� PER wsEc DISPLACE REQUIREQ INSULATlON. scale >�" `��'`�-�� �=�,� <br /> 5. RETURN AIR MUST BE DUCTED, (NON-DUCTED JOIST BAYS NOT ALLOWED). �-'' '� ��w <br /> GABLE END DETAIL ____ . <br /> _ _ � <br /> 3�H" �' �" GABLE ENDS AT 5' i�0 PROPERTY l.1NE Drawn �"'��''�,r� <br /> - � <br /> Job �� �� <br /> � ea� Sheet . . <br /> �\GK �g m <br /> , . (1�Oqti5254''Lho�ma��.c�P <br /> � �2ad2�b a¢�ti��°°m <br /> . ' vV`�W��. . <br /> ) 7r <br /> ��. <br /> � • ' NomePlanningSeNices Of .,Yy�� Sheets . <br />