-- --------1 — 2 �, 3 � 4 5
<br /> I
<br /> .-�, �, ,
<br /> ' 1 '2� �3�� ' 4 (5� �6� ( 7 � 8 �9 10 , 11 12 13 � �, 141 15 16 ) '
<br /> � ` � _� � � z
<br /> � � � � �� �
<br /> Y � � �
<br /> � i i i i i i i i i i i i i i i ' 0
<br /> TYP FRAMING OVER CORRIDORS: I I I j
<br /> i i i i i i � i-FL311 RIM AT ALL CORRIDOR WALLS � i i i i i i
<br /> � �-31/2 X 6 GLB CROSS BEAMS AS SHOWN SEE 19/S412 FOR FRAMING AT ROOF FL311 UON AT OPENINGS 1301 First Avenue, Suite 301
<br /> �-JOISTS PER SCHEDULE BETWEEN I I FALL RESTRAINT ANCHORS. ANCHOR
<br /> � � � � � , ,CROSS BEAMS , ; � � I IN EXTERIOR WALLS Seattle, WA 98101
<br /> LOCATIONS PROVIDED BY OTHERS.
<br /> � I I http://www.gglo.com
<br /> � � t � � � 2 x 8 x 12'LAPPED W/EA i i i i � � i
<br /> I I BLOCKING ATILAP. EB OPENINGS AT�14"T JI JOIS OR
<br /> D � � � � � � �� � � � � � � � � � p
<br /> � I . , 6��� . � I I'�'
<br /> I ! � � ! � ! � � . MICHAEL NOUWENS
<br /> � i � ( � � � ���; I, �
<br /> � — � FP511 � { - �-- -a--� ---� i , Structural Consultants
<br /> �
<br /> � q - — - — - - - - - — - -�- - - - -f - -�,- - - - - - - - - -- - ---- -- --_=_- - - - - - - — - '�
<br /> -- — - - - - -,;; - - - - �- - - - - -- i � - -! A
<br /> �f 305 NW 178th Street
<br /> � � �fi � �
<br /> � r� � I � � � � �I� � ��� � II � � I'� CMSTCI6 x 30' I I � I I ���
<br /> Shoretine, WA 98177
<br /> � � � I � � I I o I I I � ������-�� �� �� �, � michael@nouwens-structural.com
<br /> � �" � I � I o � I I d. I I I �� � I I I �
<br /> I SEE 19/S411 SIM AT I � www.nouwens-structural.com
<br /> I' � � '' � I I � I I � i I ,� ,, � � �
<br /> � I�I � 11/5411 ; � I I � � I �I� � �I� � I II� II 5 �I I I � P 206.546.8446
<br /> � „ I � � � -� .� � � � �� � INTEfd10R STROQTORA� I � � FI � �
<br /> 5 ��� �' �1 I �I o z I I � i I I � � IL -� � �
<br /> ^ j�\ � � � � � �- CTR BEAM ON � F. WA�LS PARALLEL TO JOISTS,TYP ' I ; � � c � I
<br /> �-.�'' `�r����-' I � � � EAST/WEST WALL "' v� � I I � : I ( I� � ,
<br /> � i , I � 1300�b MAX I �
<br /> � ' I I I I / , i � � i lil !il i i �� �i' � i � � � �� i �
<br /> ' � d' I � � UNIT PER MECM I- �
<br /> � PROVIDE BLOCKED DIAPHRAGM PER GEN STRUCT NOTES ; � I II _ � I � � � ' I I o I I I � ��� � � � � � I i
<br /> EAST OF THIS LINE. ��� � I � r" z I I w I I � u- � /` � I
<br /> DRAWINGS l;
<br /> , � i �
<br /> �� i �I� � i � I i i i � w i W � 4� i i li� ��� j� � i [,� i �5� ��. i � � T..
<br /> � � � � � � I�� FL311 0- � I � N
<br /> � v I � � ( � � �1 � � ��j � ll � � �� � �
<br /> L I cn ¢ � I
<br /> � I � � � FL311 I I i i ; i �, .r. f � i i � I i� �I i� I I FL311 i I� i �I ,C�
<br /> � I � j 7/S411 � i FL311 ON(3} � I � I I I I� ,�►
<br /> I, � � , I � i � � � SIDES OF -;j I �--i.i..- I I I
<br /> � � "' � I ' � � i i � , i i i i ROOF HATCH l i� � ;i} �� I I � � i I� i �--� m �
<br /> i � � --- � ------ ----- --- - -- - � --- -- --- - --
<br /> � - - - - - - - - - �� � - �- - - - -� -� - = -�- - - � � - � C�� '"'� _ � � I - - - - - - .--I` 2�� �
<br /> \ _ �-_ _J_� - _ ��- �- — -�_�— _ - � r-- —�` FL311 � )
<br /> � - � - �
<br /> i � I LL Ii i i �
<br /> I � � L� , ��ji � �� �I SJONAL�
<br /> --- --- - ---------�� I � 3 12-8-2017
<br /> ---- -- ---- ---- -- - -
<br /> - - - - - - - - - - - � - - - �- - -�- - i- - i -TT- - - - - -r-r ,-n- - - - -- - �- - - - � N FL311 --� — — m - — - - - I� - - - - - - - - � - - - - �� i
<br /> � � � '� � I� � � I� � � I I I I I � ��, �r� ��I � � I � �/ �' PROJECT; �
<br /> i � �/i � -� i �i� �� ��� ��� i� �� � ii � � II �;I � ��� 5 I� i j
<br /> � c�
<br /> � � i ��,,, � ��� I I � � I I I I � � � � ��� I I � � ! �� �
<br /> � � � a I� � � �' � � � � i i � � � � i i � i i��� � � �— i i i C000011 HOUS@ YOUtII
<br /> —� , . ii ii ii ii
<br /> � � � � II i i � �i� I�I I�I I�I ��� ��G �� ��I�� I�I ��� �� � I
<br /> OFFSET BEAM � � I � � I � ' ' �� � CS14 x 25'� �� I I I I I I� ��, i I .
<br /> 6'FROM GRID , � I I I , � �I� I I I ��� Center Base Contract
<br /> � ' I I I I�-- _------, , I I I � PROVIDE BLOCKED
<br /> � � ------- I
<br /> � I I
<br /> I I 1 � I I I i ROOF JOISTS PER '� ' C
<br /> �� i i I I ❑ + � i I FL311 ON 4 `�I i ,i� I'I I�-�-�- - � I�I �� DIAPHRAGM W ZONE
<br /> C ! D � _ _ _ _ _ __�-_________ _ _ _,� _ _ _ � � ' \ � � � SEE 20/S411 SIM AT , �� � FL311 ! � SCHEDU�E THIS
<br /> � �-- �, I � SIDES OF SHAFT. i I ; � � ; � I , � � I'I BETVIIEEN COLLECTOR i
<br /> ����� �� �. �o� � I� -'� � CMSTC16 x 31' �I � I I I I I ; i INTERIOR STRUCTURAL � � � � �� � � SHEET,UON ��� �� � �'���
<br /> I WALLS PERP TO JOISTS,TYP
<br /> -, AND SHEARWALL.
<br /> i i�� I --- - -�------a --u--- ��� i i ,�, �i� x I�� i� �i� �
<br /> � �' � � - --�---E-----____---,���-- I I I I I I I�I I I � �� \ ��� � '����
<br /> � � v� i � M� ;�� � I I I I I I I I I I � � ���� � � I I / ."o�j ( .
<br /> I�I � � � ��I I�I Iil � � I�I > �n � �
<br /> � � � lil i �
<br /> � i�i i ' � � �l��, li� I I I I I I I I � I I � � ��� a,�
<br /> � � I�i II� I I I I I I M I
<br /> lii I�I i i lil �i� ��_� i
<br /> INDICATES 300 Ib MAX MECH UNIT ' � ���; i i ' � I�� i I i I I I I I i c�� I
<br /> � ' � ` v ��� I ; � I I I I i I I I � �
<br /> TYP PER MECH DRAWINGS. SPAC� _� - �, � ! ; , , � � � � � II
<br /> JOISTS 16"oc AT THESE UNITS - - - -
<br /> -- -- -- --- --- /
<br /> @ - _— - --� - _ , C
<br /> AND PROVIDE FL111 ALONG UNFRAMED I j ' � �y ' s � ' � � i ' � i -� � � � � —1� PROJECT ADDRESS:
<br /> EDGES OF UNITS,TYP. CTR BM ON I � ' l ''' i � ,'
<br /> � I SEE 1/S412 FOR STEEL ' � i 3530 COLBY AVE.
<br /> � DEMISING ; i ' � EVERETT,WA 98201
<br /> I � � WALL --�� I � � � i i PLATES TO SUPPORT � i i i � i ,
<br /> �` I ! ELEVATOR RAIL BRACKETS -� W 8 x 18 SAFETY BEAM � i ;
<br /> � I I �� � I AT TOP OF ELEVATOR SHAFT. I
<br /> � , i I � � � PROVIDE FL311 CONT RIM ALL SIDES OF STAIR � 1 _ _ i_ _ _ _ _ � _ _ 1 _SEE 3/S412 AT BEAM ENDS.- - - - � - - — ��� � — _ _ — _ _ _ _ _� _ _ _ _ ��
<br /> I'I � �j � AND ELEVATOR SHAFTS,TYP ! , � f ' �
<br /> �� �� '� �'�: � � � � � ;� �
<br /> � �� - ------------ - -- SEE9& 10/S412FOR OWNER:
<br /> , i � i i i i i i i i i PARAPET FRAMING,TYP �
<br /> ��� - — - — - — - — - — - - - — �' - - -
<br /> ���� � � � PROVIDE H8 CLEPS AT JOISTS TO TOP PLATES � I COCOON HOUSE
<br /> � ! ! I� � i I I AT ALL SUPPORTS AS FOLLOWS: � ! I 292� PINE STREET
<br /> INDICATES COLLECTOR STRAP li I I i � i I i i � � -JOIST SPAN LESS THAN 14': CLIP EACH END OF ALT JOISTS. ' � � � i
<br /> TYP PER 18/S411. I I , ; EVERETT, W/4
<br /> � � � � � ; -JOIST SPAN 14 OR MORE: CLIP EACH END OF EACH JOIST. I, ; I 98201
<br /> � � �� ' I i I � i
<br /> i �� I �II i i i i i i i i i �
<br /> ` ��' I `�I � � , PROVIDE WEB BLOCKWG PER JOIST MFR EA SIDE OF WEB ; ROOF JOISTS SHALL HAVE GWB CEILING �
<br /> x AT CLIPS. CLIP NAILS SHALL ATTACH TO WEB BLOCKING AND ; i, '
<br /> � I I�� TJI ROOF JOISTS PER NOT TO JOIST BOTTOM CHORDS. USE.131 x 1 1l2"NAILS AT CLIPS. � (P E R A R C H'L)A T T A C H E D T O J O I S T B O T T O M C H O R D S. ! ;
<br /> �� � � v �� ;;� SCHEDULE UON � � � ' + ' ' ' � � '�
<br /> H — -�_-=—=__=-=_=_-- - -� ' ��� ' - — - �� - �� ����
<br /> ,
<br /> � i �� � � ��� � i I i i i i i i i i � i
<br /> SEE SECOND FLOOR FRAMING PLAN
<br /> � �� � � \ ' � i i 5 __12/08/2017 BASE CONTRACT PERMIT
<br /> � FOR ROOF OVER MUL.TI-PURPOSE,
<br /> ' GL 51/2 x 6 —� � I KITCHEN AND DAY CENTER� � I RESUBMITTAL
<br /> � � j ' � � � � � � � � ' i � � i 2 10/09f2017 ADDENDUM 2 '
<br /> 5 � � FP511 TYP AT ' � � 1 10/02/2017 ADDENDUM 1
<br /> i �i � � i i , THIS UNIT i i i i i � � i i i i MARK DATE DESCRIPTION
<br /> B � ; �
<br /> ,,�V ' i !' I ; �'\ � B REVISIONS
<br /> _
<br /> ��-�� ��--- � � i � i i i i i i i i i
<br /> -
<br /> � ' � � � .
<br /> � i �1300 Ib MAX i—� i ; i i i i � I ��
<br /> � UNIT PER MECH — GL 3112 x 6 TYP UON ACROSS CORRIDORS.
<br /> - - - - - - - - - - - - - - - - - - - - - - - - - - �� �'�.
<br /> � �� DRAWINGS I , LOCATE ON GRIDS UON. PROVIDE HUC46MAX I � � � � � t � � �
<br /> � '�, � � HGR EA END TO FL311 RIM,TYP. i i i i � i i � i � � �
<br /> i I I � � 'i
<br /> � � � � � � � � � � � � � � �� , �
<br /> I �
<br /> �
<br /> i i i i i � i � , , , , , , ; , ,
<br /> I , � ��
<br /> � � � � � � � � � � � � WOOD BEAI�I SCHEDULE � D 12/08/2017 RESUBMITTACT PERMIT
<br /> I � ' ' ; ' ' ' ' ' ' ' ' MARK ; BEAM MARK ' BEAM � — c 10/06(2017 PERMIT SET
<br /> i I I I i i I B 09/22/2017 BASE CONTRACT BID SET
<br /> � , , ROOF FRAMING PLAN NOTES , , , , , azs z-z X s ��s � sia X s��z�s� ;
<br /> � � � --- � � ; A 08/25/2017 DESIGN DEVELOPMENT
<br /> � � B28 2-2 x 8 L111 � 1 3l4 x 11 7/8 LSL __
<br /> i i �
<br /> 1. TYPICAL ROOF CONSTRUCTION SHALL CONSIST OF APA RATED SHEATHING(THICKNESS AND SPAN RATING PER GENERAL STRUCTURAL NOTES)OVER i i 6210 2-2 x 10 L35 � 31/2 x 51/2 LSL i MARK DATE DESCRIPTION
<br /> ROOF JOISTS PER SCHEDULE,UON. NAIL SHEATHING @ 6"oc AT PANEL EDGES,4"oc OVER SHEARWALLS BELOW AND 12"oc TO ALL INTERMEDIATE ISSUE INFORMATION
<br /> FRAMING MEMBERS,UON. SHEATHING NAILS SHALL BE PER GENERAL STRUCTURAL NOTES. ' ; B212 2-2 x 12 L37 31/2 x 71/4 LSL
<br /> 2. SEE ARCH'L FOR ROOF SHEATHING ELEVATIONS. DRAINAGE SHALL BE ACCOMPLISHED WITH TAPERED SLEEPERS AND ADD'L SHEATHING PER ARCH'L � � B38 i 3-2 x 8 L39 3112 x 91/2 LSL '
<br /> ROOF SHEATHING PER PIAN NOTE 1 SHALL BE CONTINUOUS BELOW OVERFRAMED AREAS. I I � 6310 3-2 x 10 L311 3112 x 11 7/8 LSL ' ' 2016030.��
<br /> 3. SEE 9&1Q/S412 FOR WALL FRAMING AT ROOF EDGES. B48 4 x 8 P39 31/2 x 1/2 P PROJECT NO.:
<br /> 9 SL �
<br /> � PRINCIPAL IN CHARGE:
<br /> 4. PROVIDE(2)BEARING STUDS MINIMUM EACH SIDE OF OPENINGS AND BELOW EACH END OF HEADERS. PROVIDE 3 BEARING STUDS MINIMUM BELOW B410 4 x 10 P59 i 51/4 x 9112 PSL
<br /> ( ) PROJECT MANAGER: Michael Nouwens
<br /> � BEAM LOCATIONS. MULTIPLE BEARING STUDS SHALL CONTfNUE THROUGH LEVELS BELOW TO FOUNDATION. PROVIDE SOLID BLOCKING THROUGH B412 4 x 12 P79 7 x 91/2 PSL ROOF JOIST SCHEDULE OWNER APPROVAL:
<br /> INTERMEDIATE LEVELS. SEE ALSO 2&6/S4.10 --- - F� -
<br /> 668 6 x 8 P311 31/2 x 11 7l8 PSL 10 psf PV ARRAY LOAD `W ;
<br /> A 5. SEE ARCHITECTURAL AND MECHANICAL DRAWINGS FOR LOCATIONS AND SIZES OF ROOF OPENINGS. VERIFY LOCAT�ONS AND WEIGHTS OF MECHANICAL 6610 6 x 10 P511 51/4 x 11 7/8 PSL 2S pSf SNOW LOAD , A
<br /> UNITS WITH MECHANICAL DRAWINGS. PROVIDE FL311 ALONG SIDES OF MECHANICAL UNITS AND AROUND SIDES OF MECHANICAL OPENINGS. �-
<br /> i 6. SPLICE TOP PIATES PER 1/S410,TYP. 6612 6 x 12 P711 i 7 x 11 7/8 PSL CLEAR SPAN �,, I� SHEET TITLE
<br /> �oisT ROOF FRAMIN PLA
<br /> LV17 1 3/4 x 7 1/4 LVL P714 ' 7 x 14 PSL � ; G N
<br /> 7. VERIFY DIMENSIONS WITH ARCHITECTURAL DRAWINGS. DO NOT SCALE STRUCTURAL DRAWINGS. 16'max ' 11 7/8"TJI 110 @ 24"oc W '
<br /> P514 5 x 14 PSL P716 7 x 16 PSL � ',
<br /> 17'-6"max I 11 7l8"TJI 210 @ 24"oc �
<br /> �--� ���� ������� ���� P516 5x16PSL P718 7x18PSL � �"� i
<br /> a � ` 18'-6"max i 11 7l8"TJl 230 24"oc V
<br /> � — FLUSH-FRAMED BEAMS ARE NOTED WITH AN"F"PRECEDING �
<br /> � ; � � % 1/8"=1'-0" THE BEAM MARK: FB212, FL311,etc. 19'-6"m� �� 11 7/8"TJI 360 @ 24"oc
<br /> � � �-� � � � SHEET N0.
<br /> s AT FLOORS,TOP OF FLUSH WOOD BEAM IS AT TOP OF JOIST 21'-6"max i 11 7/8"TJI 560 @ 24"oc
<br /> N ELEVATION. AT ROOF,BOTTOM OF FLUSH WOOD BEAM IS AT O i
<br /> a BOTTOM OF TRUSS ELEVATION.
<br /> c !
<br /> � -113
<br /> w � �
<br /> 0
<br /> o _ _ m COPYRIGHT MNSC.ALL RIGHTS RESERVED.
<br /> a
<br /> -- _ ORIGINAL SHEET SIZE IS 24"x36"
<br /> 1 � 2 3 I 4 5
<br />
|