Laserfiche WebLink
� 2 3 4 5 <br /> 36"MIN.CLEAR INSIDE FOR ROLL-IN SHOWER STALLS,MIN 30"DEEP BY 60"LONG, 60"MIN.CLEAR <br /> • NOTE: WHERE ACCESSIBILITY IS REQUIRED, INCLUDING TYPE A UNITS,THE OPERATING PARTS OF LIGHTING CONTROLS, ELECTRICAL SWITCHES AND PROVIDE A MIN 36"WIDE BY 60"LONc� pARALLEL TO THE <br /> RECEPTACLES, ENVIRONMENTAL CONTROLS,APPLIANCE CONTROLS,OPERATING HARDWARE FOR OPERABLE WINDOWS, PLUMBING FIXTURE z (36"EXACT AT TYPE A) � <br /> CONTROLS,AND USER CONTROLS FOR SECURITY OR INTERCOM SYSTEMS SNALL COMPLY WITH SECTION 309 OF ANSI/ICC A117.1-2009. DRYING � SHOWER)CLEAR FLOOR SPACE PER ANSI(ICC A117.1-2009 <br /> N SECTION 608. PROVIDE A SHOWER SPRAY UNIT MIN. 59"LONG. � <br /> EQUIPMENT,TOWEL OR CLEANSING PRODUCT DISPENSERS,AND DISPOSAL FIXTURES SHALL B3 40"MAX AFF FOR REACH DEPTHS LESS THAN 6"PER � _ T 32"M►N. , Z <br /> IBC 1101.2.7 AND WAC AMENDMENTS. ` ; �� „ ,� � i NOTE:SHOWER ENCLOSURES SHALL NOT CLEAR � ! C� <br /> 3 6 X 4 8 � � O B S T R U C T C O N T R O L S O R T R A N S F E R M A N E U V E R I N G ¢ v y <br /> OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING,PINCHING,OR TWISTING OF THE WRIST.TH E � ¢ � S E A T CLEAR i F R O M W H E E L C H A I R T O S H O W E R S E A T S C L E A R A N C E S A T D O O R S � ; w <br /> �n a ' \\ �/ � FLOOR i f� � ; � <br /> FORCE REQUIRED TO ACTNATE OPERABLE PARTS SHALL BE 5 POUNDS(22.2 N)MAX. Z � � � 'u - J� SPACE 1 1/2"DIA GRAB BAR,TYP 18"MIN z ' <br /> SEE WATER CLOSET GRAB BAR � a � ; 'i \ <br /> DETAIL DIMENSIONS,TYP i m � � Q � -�� � ' ,' � i `� CLEAR o <br /> � FINISH WALL m o , INSULATE Z �-� � �_ �y , HAND-HELD SHOWER WITH 59"HOSE AT � CO 1301 First Avenue, Suite 301 <br /> TYPE A AND LIVENVORK UNITS ' � <br /> 12"MIN�F TPH IS � � z J / EXPOSED HOT � � CONTROL WALL � ' Seattle, WA 98101 <br /> 42"MAX.IN RE51D.UNITS � � � �j / WATER AND DRAIN g w / <br /> BELOW GRAB BAR � z z ' <br /> \ - u' w ' � PIPES,TYP — �o � j� NOTE: GRAB BARS ARE NOT REQUIRED , <br /> T.O. FLUSH � M � � htt //www. lo.com <br /> '�� 24°MIN. IN UNITS o� ' — � j PROV�DED BLOCKING HAS BEEN PROViDED 1'-0"MIN CLEAR p� gg <br /> �`CONTROLS <br /> � �_� ,—�I � _ ___ � O - � MIRROR `� �' TO INSTALL GRAB BARS AS SHOWN. <br /> � �— <br /> � o � � � o � ; , � / GRAB BARS SHALL EXTEND ACROSS THE ALL F�NISHES MUST BE INCLUDED IN CALCULATING MINIMUM. CLEARANCES. MEASURE <br /> D � '� ��-'' „ „ � Q , �� w 4 M�� CONTROL WALL AND ON THE BACK WALL FROM NEAREST FINISH SURFACE TO NEAREST FINISH SURFACE, I.E. BASEBOARD TO <br /> g � 7 MIN,9 MAX IN i w w ; j � � z �-� � Q ; ; �°" B A S E B O A R D. D <br /> � � � �{� PUBLIC BATHS �n,c� � � ; � � � j c� 0 � w� ��� � � / LOCATE SEAT ON WALL OPPOSITE <br /> � ! �� g g ; _ � _ � � � _ '� � � c n � � w � �- / S H O W E R C O N T R O L S(S E A T P R O V I D E M I N I M U M 1 8"CL EA R(INCLUDiNG AT BASEBOARD)BEYOND LATCH SIDE FOR <br /> z � - � � T.O.SEAT �� - - RIM �* ,�, � � � � o � c� <br /> 0 0 � v g ;v - - ; g W `-'� W ; OPTIONAL,BLOCKING IS REQUIRED) ' <br /> � j �+ �-o,� , v v —�-� ,� � o � � � w _ z ;�' / 18" FRONT APPROACH TO PULL SIDE OF DOOR. IF DOOR IS SELF-CLOSING AND SELF- 5141 "`"" "'""`" <br /> � I z Z � � I I ; i M j o j "" w z = � � N � � �o z � I ' , �' LATCHING, PROVIDE MINI M U M 1 2°C L E A R B E Y O N D L A T C H O N P U S H S I D E O F D O O R. y� ���'t-[�i�•'r:D <br /> � � ¢�� ; > � O w � � i� a ��� t��Ti�l �CT <br /> M � � �� � ' � � � i � �o �w � - v �' MIN. ' • <br /> � <br /> ' � � � � �---� � � j � � o z " � �m w � � � � o� - - _ ] PROVIDE MANEUVERING CLEARANCES AT ALL DOORS IN TYPE A UNITS,THE ENTRY e , _ , <br /> T � � ' T ►= � � ! �- Q � �oFFSE� _ � DOOR AT TYPE B UNITS AND ALL PUBLIC AREA DOORS PER ANSI/ICC A117.1-2009 --- <br /> SEAT COVER NAPKIN TOILET ACCES IBLE T I ' � ; � �''> �CONTRmLS M �°, � SECTION 404. '� <br /> SHKOSKI <br /> S 0 L E T S P A P E R T O W E L S A N.N A P K I N/ U R I N A L S O A P C O U N T E R M I R R O R i 3" 6" ' U � ; [�� M �" � J 1 1!2"�ar' S T A T Q F W A S H I N G T O N <br /> DISPENSER DISPOSAL PAPER DISPENSER/ TAMPON DISPENSER � 0 1$"M'°'X I �-M,q)( ;; ENTRY DOORS TO UNITS TO HAVE 1/4"MAX THRESHOLD OR 1/2"MAX.WITH A 1:2 MAX, <br /> HOLDER RECEPTACLE DISPENSER TOE N ,�� -�� BEVEL. AT EXTERIOR SLIDERS 3/4"MAX.THRESHOLD WITH A 1:2 MAX BEVEL. AT TYPE lx.,•!3i' ("T <br /> CLEARANCE � = CONTROL WALL BACK WALL SEAT WALL B ONLY,WHERE EXTERIOR DECK, PATIO OR BALCONY SURFACE MATERIALS ARE <br /> MOUNTING HEIGHT DETAIL — BATHROOMS ~ IMPERVIOUS,A4��STEPISALLOWED. <br /> �� �,2��_ ��_��� T RA N F R <br /> S E SHOWER STALL <br /> D4 �,4�,_ ,,_o,. RESIDENTIAL ENTRY <br /> NOTE: WHERE ACCESSIBILITY IS REQUIRED, INCLUDING TYPE A UNITS,THE OPERATING PARTS OF LIGHTING CONTROLS, LAUNDRY EQUIPMENT CONTROLS AND OPERATING MECHANISMS, INCLUDING DOORS, LINT SCREENS, <br /> ELECTRICAL SWITCHES AND RECEPTACLES,ENVIRONMENTAL CONTROLS,APPLIANCE CONTROLS,OPERATING DETERGENT AND BLEACH COMPARTMENTS SHALL COMPLY WITH REACH RANGES PER ANSI/!CC A117.1- 2'-6"MIN. 2'-6"MIN. � 1/4" = 1'-0" <br /> HARDWARE FOR OPERABLE WINDOWS, PLUMBING FIXTURE CONTROLS,AND USER CONTROLS FOR SECURITY OR 2009. FOR ROLL-!N SHOWER STALLS, MIN 30"DEEP BY 60"LONG, <br /> INTERCOM SYSTEMS SHALL COMPLY WITH SECTION 309 OF ANSI/ICC A117.1-2009. (48"MAX TYP REACH RANGE,OR 44"MAX�OR FORWARD APPROACH W/OBSTRUCTIONS OVER 20"DEEP -6"MAX. i PROVIDE A MIN 36"WIDE BY 60°LONG(PARALLEL TO THE <br /> AND 34"-44"MAX FOR SIDE APPROACH W/OBSTRUCTIONS) � i i SHOWER)CLEAR FLOOR SPACE PER ANSI/ICC A117.1-2009 <br /> o OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPiNG,PINCHING, - T SECTION 608. <br /> o OR TWISTING OF THE WR1ST.THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS(22.2 N) COAT AND BEDROOM CLOSETS IN TYPE A UNITS:A PORTION OF THE STORAGE AREA SHALL BE INSTALLED � �i <br /> � i NOTE:SHOWER ENCLOSURES SHALL NOT <br /> w o M� WITHIN THE REACH RANGES OF MAX 48", MIN. 15°(ANSI/ICC A117.1 -2009 SECTION 1003.14,308} '� _ �'J ` ' <br /> o a � ' ' � OBSTRUCT CONTROLS OR TRANSFER FROM <br /> VISION LITES AND PEEPHOLES,WHERE INSTALLED AT TYPE A UNITS,SHALL BE PLACED SO THAT THE BOTTOM OF � Zr, ; CLEAR i WHEELCHAIR TO SHOWER SEATS <br /> � = FLOOR � <br /> UO THE PANEL OR PEEPHOLE IS 43 INCHES MAX ABOVE THE FLOOR; INSTALL AT 68 INCHES MAX AT OTHER UNITS � � SPACE ' 1 1/2"DIA GRAB BAR TYP ` <br /> � Q ���� --- - - - - -� ��_ � ` i NOTE: GRAB BARS AND SHOWER SEATS ARE NOT PROJECT: <br /> a Z z � � R E Q U I R E D P R O V I D E D B L O C K I N G H A S B E E N <br /> Q o o p = cn �w I CONTROL WALL P R O V I D E D T O I N S T A L L G R A B B A R S A S S H O W N. � Cocoon House Youth <br /> ,,., � , � � SPOUT ! v � �-- HAND-HELD SHOWER WITH 59"HOSE AT TYPE A AND � <br /> � 11 ' Qz _ � ° z ' w � � c.i <br /> w = I o o _ c � 'J -- ~ � w o c~n � O O O�O �„M� LNENVORK UNITS �:�� � Center - Base Con#ract <br /> C � � "' m � � � � �� � � �� B RS, BUT NO H GHER T�HAN 48"A OVE THE��B ��� C <br /> � I <br /> -' o = � ;� ; j W � � �' W � � o ,� � 1 , � <br /> � � , � a � ' z � ' � o j p z � � ►- " � � � ,1 / SHOWER FLOOR <br /> z o I Q o M � � o --��� � � I o v � o Z � - - Q L O C A T E S E A T O N W A L L O P P O S I TE S HOWER � <br /> � � �i � o N � o w,; � � � z q g �� ; ; CONTROLS(SEAT OPTIONAL,BLOCKING IS - <br /> ca w ' � "- � � I o = � � � REQUIRED) � � <br /> 2 � `tO I � � ap �U � � ' J � <br /> —� Z p ONTRO�S � <br /> o � LIGHTING, ENVIRONMENTAL DRWKING ELECTRICAL OUTLET AND~ LAUNDRY EQUIPMENT TOILET PAPER MOUNTING L� � _ _ _ _ _ _ _ _ `�}-- - - CHANGES IN LEVEL OF FLOOR SURFACE ARE LIMITED T01/4" <br /> � '� &APPLIANCE CONTROLS, FOUNTAIN COMMUNICATION HEIGHT - g VERTICAL OR 1/2"BEVELED AT 1:2. CHANGES IN LEVEL GREATER <br /> � AND FIRE ALARM PULL SYSTEM RECEPTACLES r`�,� o �� r`°,� ��� M THAN 1/2"SHALL BE RAMPED ACCORDING ICC(ANSI A117.1 SEC <br /> � � STATIONS �� M , � C M �e 1 1/2° � M 405 OR 406. NO CHANGES IN LEVEL ARE PERMITTED IN A TURNING <br /> '��� _�___� _ "��M� � SPACE. PROJECT ADDRESS: <br /> M 0 U N T I N G H E I G H T D E TA I L — G E N E RA L �= CONTROL WALL BACK WALL OPPOSITE WALL AC C E I B 3530 COLBY AVE. <br /> �� ~ S S L E T H R E S H 0 L D EVERETT, WA 98201 <br /> �,2��_ ��_��� ROLL—I N SHOWER STALL C5 3"= 1�_0�� <br /> SUBTOP PERMANENTLY SCREWED/ C� 1/4"= 1'-0" <br /> GLUED TO SKIRT BOARD DIMENSION VARIES-SEE TYPE A AND TYPE B <br /> T.O.SINK RIM _� --�� BATHROOM REQUIREMENTS OWNER: <br /> � THE WALLS BEH►ND SURROUND►NG CQCOON HOUSE <br /> / CABINETRY MUST BE FINISHED. �- INSTALL BODY OF BASE 2929 pINE STREET <br /> T.O.COUNTER _ � _ ' \� 60' A LAVATORY IS ALLOWED IN THE CLEAR FLOOR CABINET W/SCREWS, <br /> � � �g�� � SPACE OF A WATER CLOSET PROVIDED THAT � , <br /> i <br /> � ; � �-�k- � KNEE AND TOE CLEARANCES ARE MET,SEE � l� 16"X16"STEEL ; � WDEPENDENT OF EVERETT, WA <br /> z ' W � MIN. ( � TYPE A BATHROOM DETAIL � 200#CAPAC�ITY MIN / RE�MOVALTOP FOR EASY 98201 <br /> � � <br /> � i <br /> � � � I �� � � <br /> o � SKIRT BOARD WITH ; � � ( � I <br /> i � <br /> � � FINISHED FRONT FACE �-� � <br /> � ,.,.i � SCREW TO END PANEL <br /> o = REMOVABLE SCREW ;i; � CLEAR CABINET(S)UNDER COUNTERTOP SHALL BE , / I � &ADJACENT CABINET _ <br /> , i EASILY REMOVABLE WITHOUT REMOVAL OR WARNING STRIP ON <br /> FLOOR � LEADING 2"OF TREAD <br /> � � METAL SPLICE � � LL SPACE REPLACEMENT OF THE LAVATORY TO PROVIDE PARTIAL CABINET <br /> Q CLEAR FLOOR SPACE FOR TOILET. ADJACENT a <br /> M � `� !� � � CABINET PANELS TO BE FINISHED. o � � SUPPLIED BY MFR � <br /> � C A B I N E T F R A M E � � INCLUDING DOORS,TOP <br /> I i FINISH FLOOR MUST EXTEND UNDER CABINETRY W ' � u' ' � RAIL,SIDE STILE AND 2 10/09/2017 ADDENDUM 2 <br /> ' z ,i > 1/2"MAX RADIUS <br /> AND WALLS BEHIND AND SURROUNDING � � � d o BOTTOM <br /> �1 � o � / � AT EDGE OF TREAD MARK DATE DESCRIPTION <br /> B � R , SKIRT BOARD CABINETRY MUST BE FINISHED. � c.� � � ~ � r / B REVISIONS <br /> �/ ATTACHED TO CABINET ' � _ <br /> o � �„ <br /> Z F- J <br /> 1. REMOVE SCREWS � � Z ! w 30°MAX ANGLE <br /> AS SHOWN �, i = � z �\' <br /> B SEE REQUIREMENTS IN TYPE A � Z � N � � FOR SLOPE <br /> � r AND TYPE B BATHROOM � � F I N I S H F L O O R I N G SHALL , U N D E R T R E A D <br /> DETAILS TO DETERMINE WHEN � BE INSTALLED BENEATH <br /> � � t � REMOVABLE CABINETRY IS � ALL REMOVABLE I I <br /> � ' REQUIRED. ; � CABINETRY I " <br /> � � ' � i j I . <br /> \ � � � SHIM ALL CABWET IN ' ' <br /> REMOVABLE CABINET DOOR AND FRAME STYLE -""� i GROUP TO MATCH FLOOR � <br /> � TO MATCH PERMANENT CABINETS. FINISH HEIGHT 1 1/2"MAX PROJECTION OF NOSING <br /> � <br /> �, REM4VABLE CABINET DIAG. R/� REMOVABLE CABINETRY ACCESSIBLE STAIR NOSING <br /> B3 1/4"= 1'-0" V`T 1 1/2"= 1'-0,� B 5 1 1/2"= 1'-0,. <br /> D 12/1312017 BASE CQNTRACT PERMIT <br /> RESUBMITTAL <br /> LOCATE A COUNTER SURFACE, MIN.30"WIDE X 24"DEEP AT 34"AFF MAX.,WITH A KNEE SPACE OF C 10106/2017 PERMIT SET <br /> FINISHED F100R WALL,AND TRIM � AT LEAST 27"IN HEIGHT. CABINETS PERMITTED UNDER WORK SURFACE AND SINK PROVIDED IT CAN 24" <br /> � ,1 BE REMOVED W/OUT REMOVAL OR REPLACEMENT OF WORK SURFACE, FINISH FLOOR EXTENDS � � B 09/22/2017 BASE CONTRACT BID SET <br /> ��� BEHIND CABINET � UNDER CABINETRY,AND WALLS BEHIND AND SURROUNDING CABINETRY ARE�INISHED. ', MAX. ! <br /> KNEE BRACE PERMANENTLY ' I A 08/25/2017 DESIGN DEVELOPMENT <br /> 2.SLIDE CABINET OUT I ATTACHED TO TOP AND WALL 1, PROVIDE 60"CIRCULAR OR T- ' N z <br /> � PROVIDE BLOCKING FOR KNEE 251/2"MAX.TO EDGE OF ', S H A P E D T U R N I N G S P A C E P E R� _ - _ '- � � MARK DATE DESCRIPTION <br /> � BRACE. 1 ICC/ANSI SECTION 304 IN EACH / � THE SINK AND SURROUNDING COUNTERTOP � � \ \ --�- , Q , <br /> \� COUNTERTOP @ TYPE B� -f-ROOM_ _ _ _ , ' % SHALL BE 34"AFF MAX.(MEASURED TO RIM). ' � � �, A z ,� z I z � ' ISSUE INFORMATION <br /> ' ,�ti 24'MAX.@ TYPE A, �, - ADJUSTABLE SINK AND COUNTER ALLOWED IF � ACCESSIBLE ROUTI� � � ! T-SHAPED SPACE � � � <br /> � �P�" ACCESSIBLE � \�� - - - _- - i - � ROUGH-IN PLUMBING PERMITS CONNECTION OF / 6�,p�PM SpA E � M I' ° ' � � � <br /> � ` � � / i p� , PIPES FOR SINKS MOUNTED AT 29"AFF. �� ,��RN�NG �_ � � <br /> , � <br /> � i - - - -- PROVIDE CLEAR FLOOR SPACE ADJACENT TO �'� � � `�, ��, � `" �, � � PROJECT NO.: �O�6030.00 <br /> � � i � � � i z �- <br /> I � I�� /�I � DISHWASHER DOOR, SO THE DISHWASHER DOOR � � � � , GGLO PRINCIPAL IN CHARGE: Michael Wishkoski <br /> � —�o I i I � � � Q IN AN OPEN POSITION DOES NOT OBSTRUCT THE ; <br /> � w I 36"MIN. GGLO PROJECT MANAGER: Scott Schreffler <br /> � m �� / � � CLEAR FLOOR SPACE FOR THE DISHWASHER OR OWNER APPROVAL: <br /> � � _ �� ���j- ; z I AN ADJACENT SINK. � <br /> � ¢ " � � �� \'� CLEARANCE BENUEEN ALL OPPOSING BASE ALL FINISHES MUST BE INCLUDED IN CALCULATING MINIMUM CLEARANCES. MEASURE W <br /> A � a �� I I` I � CABINETS,COUNTERTOPS,APPLIANCES,OR FROM NEAREST FINISH SURFACE TO NEAREST FINISH SURFACE, I.E. BASEBOARD TO � A <br /> i � L � � �?� I WALLS WITHIN KITCHEN WORKAREAS SHALL BE BASEBOARD. ~ SHEET TITLE <br /> � - NOT LESS THAN 40". ACCESSIBLE ROUTES OF TRAVEL MUST BE FREE OF OBSTRUCTIONS AND MAY BE � <br /> . <br /> �-� REF �— TYPICAL 30"x48"CLEAR FLOOR SPACE FOR REDUCED TO 32"MIN. FOR A MAXIMUM DISTANCE OF 24". � ACCESSIBILITY DETAILS <br /> 36"@ TYPE B �� � APPLIANCES. CENTER THE CLEAR FLOOR SPACE W <br /> ! 34"@ TYPE A,ACCESSIBLE ON EACH APPLIANCE,TYP(FHA) SEE ANSI/ICC A WHEELCHAIR TURN�NG SPACE MUST BE PROVIDED CONSISTING OF EITHER A 60" a <br /> � � A117.1-2009 SECTION 1003.12 FOR FORWARD OR DIAMETER CIRCLE OR A'T SHAPED INTERSECTION WITHIN A 60"MIN.SQUARE WITH ~ <br /> \ � PARALLEL APPROACH REQUIREMENTS(VARIES (� <br /> � AT EACH APPLIANCE). ARMS AND BASE 36"WIDE MIN. EACH ARM OF THE'T'SHALL BE CLEAR OF <br /> $ SWITCH FOR EXHAUST � \�` OBSTRUCTIONS 12"MIN. IN EACH DIRECTION AND THE BASE SHALL BE CLEAR OF � <br /> N FAN SHALL NOT MIN. 50%OF FREEZER SHELF SPACE IN COMBO OBSTRUCTION 24"MIN. KNEE AND TOE CLEARANCES ALLOWED ONLY AT THE END OF <br /> � ELEC OUTLETS 4VER � Z SHEETNO. <br /> � REQUIRE REACHING REF/FREEZERS SHALL BE WITHIN 54' MAX.AFF. EITHER THE BASE OR ARM. <br /> M ACROSS BURNERS. (SIDE X SIDE RECOMMENDED) <br /> � REMOVABLE CABINETS COUNTER � 2 . <br /> � TYPICAL POD KITCHEN ACCESSIBLE ROUTE A �O <br /> ¢ A� „2�� _ ,�-o�� A2 „2��_ ,�-o�� A4 A5 � <br /> � 1/4"= 1'-0" 1/4"= 1'-0" a <br /> 0 <br /> a m COPYRIGHT GGLO.ALL RIGHTS RESERVED. <br /> ORIGINAL SHEET SIZE IS 24"x36" <br /> 1 2 3 4 <br /> 5 <br />