My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2320 RUCKER AVE EVERETT NEUROLOGICAL CENTER 2018-01-02 MF Import
>
Address Records
>
RUCKER AVE
>
2320
>
EVERETT NEUROLOGICAL CENTER
>
2320 RUCKER AVE EVERETT NEUROLOGICAL CENTER 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2023 7:37:53 AM
Creation date
5/7/2019 2:58:46 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
2320
Tenant Name
EVERETT NEUROLOGICAL CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> ,' <br /> � <br /> / <br /> � t� . ���:'tt <br /> �ir�' ! �. <br /> m <br /> ay � <br /> ay y Robert �uCCerfield & Associates AIA <br /> t. Iday Fl, 1990 <br /> y �y H Page Two <br /> � H� <br /> � y H 7. Walls and ceilings of corridors are required to be of 1-h62 <br /> � z� �� fire-resistive construction. Section 3305(g)- An architectural <br /> py c section through the corridor is necessary to determine fiow this is <br /> ac`comp1i3t5eZ1.--- <br /> �.�g �� 8. Interior openings into co:ridors are required to be protected as set � <br /> forth in Section 3305(h). Self-closing or automatic closing <br /> � y� twenty-mi.nute rated door assemblies properly gasketed should be ' <br /> �..x3 provided. Other openings are limited to 1/4 inch thick wired glass <br /> g �' set in steel frames, and shall not exceed 25% of common wall. � <br /> H <br /> ndy f <br /> � t�r 6/C 9. Enclosed useable space under interior stairways is required to be <br /> � y y protected on the enclosed side as required for 1-Hr fire-resistive ; <br /> y o y construction. Section 3306(m). <br /> 10. Fire dampers should be installed in the following locations as per <br /> Section 4306(j). <br /> e�GG <br /> a. Ducts penetratin9 the ceiling of fire-resistive fl.��r-ceiling or <br /> �ax roof-ceiling assemblies. <br /> __ ha�- <br /> � b. Ducts penetrating fire-resistive elements of fire-rated corridcr <br /> "`�� walls. See exceptian for steel ducts with no openings into <br /> corridor. {��5-�- 'rso�Q, F�-�15 a �GGt��S <br /> R�. ( 11. Gypsum board or plaster ceilings in conjunctiun with t'ire-resistive � <br /> � d/� assemblies should be supported at intervals not exceeding 16 inches. <br /> I'- �"j <br /> Item 13, Table IJo. 43-C (see also Footnote a). <br /> " '"' 12. Exit doors should be openable from the ir�side without the use of a <br /> key, special k�owledge or effort. See exception fez allowing <br /> � pf� key-locking hardware on the main exit of Grnup B, Division 2 <br /> .k. „� Occupancies. SurPace mounted flush or surface bolts are prohibited <br /> (R-3 occupancies excepted). Automatic flush bolts are allowed on <br /> pairs of doors provided the door witli the flush bolt has no knobs or <br /> E�' ! � surface mounted hardware and the unlatching oP any leaf requires only <br /> ' a single operation. Section 330�i(c). <br /> �"' � �f� 13. The length of the landing measured in the directior, oi' travel should <br /> + -,� not be less than 44" Section 3304(j). <br /> pK 14. Exit corridors should not be interrupted by intervening rooms. <br /> Section 3305(a). <br /> � 15. Dead end corridors are limited to 20 feet. Section 3305(e). <br /> � <br />
The URL can be used to link to this page
Your browser does not support the video tag.