Snohomish County 4/29/2019
>
Contracts
>
6 Years Then Destroy
>
2023
>
Snohomish County 4/29/2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2019 9:56:18 AM
Creation date
5/9/2019 9:56:06 AM
Metadata
Fields
Template:
Contracts
Contractor's Name
Snohomish County
Approval Date
4/29/2019
Council Approval Date
4/17/2019
End Date
10/31/2023
Department
Public Works
Department Project Manager
Mark Sadler
Subject / Project Title
Smith Island Pump Station O & M
Tracking Number
0001756
Total Compensation
$0.00
Contract Type
Agreement
Contract Subtype
Interlocal
Retention Period
6 Years Then Destroy
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERATOR LOAD BANK CHECKLIST <br /> Location: <br /> Date: <br /> Operator: <br /> Load Banking <br /> • Notify Dispatch <br /> • Note generator Voltage and max. KW <br /> • Ensure load bank voltage links are correct for the generator voltage output <br /> • Turn the generator HOA switch is off <br /> • Turn off generator main breaker <br /> • Remove the station load conductors from the generator breaker <br /> • Attach the load bank load conductors to the generator main breaker <br /> • Attach the load bank neutral to the generator of transfer switch <br /> • Attach the load bank ground conductor <br /> • Ensure all the load bank breakers are in the off position <br /> • Start the generator in the manual/hand position <br /> • Turn the load bank fan selector switch to the internal position <br /> • Push and hold the fan start/fail reset button to start the fan <br /> • Reset the load bank main breaker(located on the side of the unit) <br /> • Select and turn on breakers to provide 25%load for 3.hour <br /> • Select and turn on breakers to provide 50%load for 1 hour <br /> • Select and turn on breakers o provide 75%load for 2 hours <br /> • Remove all load from the generator and allow it and the load bank to cool down <br /> Return generator to service <br /> • Ensure generator HOA switch is off <br /> • Ensure generator breaker is off <br /> • Disconnect the load bank conductors <br /> • Reconnect the station load conductors (ensure correct phase) <br /> • Turn on generator main breaker <br /> • Put generator HOA switch in auto position <br /> • Test generator and ATS operation <br /> • Notify dispatch that the work is complete <br />