Laserfiche WebLink
c.��� <br /> � . <br /> ���� Fhl 3 3 BACK OF WALK tEAS MAENT <br /> ��C. 5 3 � <br /> � (NP) U <br /> � . <br /> F- <br /> �p0� w �`--G G 6 —� —�— � --G--- 2 <br /> 01X � ` 4 � <br /> � w w w ' w w w w w w 4' <br /> w <br /> �'tP SS ry `��„� � 285 LF 12"�s HDPE —— � _ � <br /> s ss o �S° ----s�-�s�— �'—— ss` - ss r <br /> J�� `� . ' � n o -' . <br /> �V`Z` �r� � 8 0o Q --� -�-�-� -3-a P_-__p____p-___P-__-P____P__ N � � <br /> �P �\ ��"'�__ _ �_ 13IH�7BEEzP --ss-�e_-- P____P____ _ _—� _ { <br /> •c��. S , " - rn <br /> ��� SS SS SS SS N SS SS SS SS- SS <br /> �� Q <br /> . ��\ / . - �� . <br /> � / <br /> �1 e� � —'� � —T --� _-z=r_S=r- =s=r=—s= __ =r — `'' <br /> �—o--' . �, z <br /> f/ r� — — --- — --- — --- �' s so '—� <br /> — x <br /> so --� ---- -- .� v <br /> d� �J—=c= — �----c----�----�----�----�----� -- c---�----�--- Q <br /> ,_, � <br /> BACK Of WALK <br /> LEGEND; CONSTRUCTION NOTES: NOTES: <br /> W WATER MAIP{ Oj NOT USED TNIS SHEEf 1. SEE TABLES ON SHEET C9.t FOR FlRE <br /> HYDR4NT, WATER MAIN FlTI1NG AND VAIVE> <br /> G NATURAL GAS LJNE O �OT USED THIS SHEEf AND DOMESTiC WATER AND FlRE SERVtCE <br /> So - PROPOSED STORM DRAFN LINE LQCA710NS. <br /> �3 FIRE HYDRANT ASSEMBLY <br /> SS � PROPOSEQ SANITARY SEWER LtNE 6" 4 DI LEAD 2. SEE SHEET C9.1 FOR STANDARD CCIY <br /> THRUSf BLOCKWG DETAIL REFERENCE. <br /> ---P-- PROPOSED POWER FJNE t <br /> --T--- PROPOSED VERIZON TELEPHONE tJNE �4 NOT USED THIS SHEEf 3. NATURAL GAS UNE-LOCATION IS SCHEMATIC. . ' <br /> SEE PUGEf SOUND ENERGY DESIGN. <br /> ---c--pROPOSED COMCAST CABLE LINE O �4} 12-,p gUTfERRY VALVE, FlxFL ' <br /> --—--EASEMENT UNE (1} 12'0 HDPE SPACER BEiWEEN 4. WHERE WATER AND NATURAL GAS ' <br /> VALVE AND HDPE ?IPE <br /> DS/FS_ DOMESTIC WATER SERVECE & FIRE SERVICE INTERSECT EACH OTHER; DEFLECT WATER <br /> O6 NOT USED THIS SHEET UNE UNDER NATURAL GAS UNE AT ' . <br /> N GATE VALVE CROSSING, UNLESS NOTEU OTHERWISE ON <br /> Wp BUTfERFLY VALVE O7 NOT USED THIS SHEEf DRAWING. <br /> L BLOW-OFF ASSEFABLY 5. PROVIDE 12-INCH MlNIMUM CLEARANCE <br /> OS NOT USED THkS SHEEf BEfWEEN UTILITIES AT CROSSINGS, UNCESS <br /> �l FlRE HYDRANi ASSEMBLY Og NOT USEQ THIS SHEEf NOTED OTHERWISE. a ° <br /> t=I TEE <br /> Ti 90' ELBOW 10 NOT USED THIS SHEET ���`� ��������--..- �� � ,�' <br /> � THRUST BLOCKING 11 NOT USED THIS SHEEf � q - <br /> 4�s � �� � <br /> K REpUCER 72 NOT USED THIS SHEEf ��C SERVICES OATE PUBLIC WORKS# <br /> � n CAP � DEPARFMENT� <br /> � UTill i$ DflA1NA�E � � <br /> � WM METER VAULT (SEEO� � � RPUBIICHbPKSVEqNITI6qE0U1PEAPNOFlf �. ' � <br /> ro � TY OINEER PRp.IECi.,A PpOVlLL FON THIS iflOJECT IS' <br /> �SDMH PROPOSED STORM DRNN MANNOLE <br /> � . � - CONOITIONRt PEN FUflPEkT STANDAPDS' ; . <br /> � 1�g PROPOSED CATCF! BASIN o��x�*�'�F�EssoE�M�- /� KEY MAP � i <br /> 'v !SS PROPOSED SANITARY SEWER MANHOLE `% NOT TO SCALE � <br /> � � PROPOSED STORM DRAIN FILTER N � <br /> � 0 PROPOSED VERIZON SERVICE VAULT <br /> m <br /> 0 <br /> � m PROPOSED COMCAST SERVICE VAULT SCALE IN FEEf <br /> a OB VALVE & Ft'ffING LOCATION (SEE C9JJ „�„ <br /> $ -v- DEFLECT TO CROSS UNDER OTHER U'CIL1N z0 0 20 4o NOTL� DOES NO MT EASUR 1" <br /> � a-p PROPOSED LtGHT POLE AWUST SCALES ACCORDIN�LY, <br /> N <br /> / <br /> � : PROJECT ENGINEER: SCALE ; <br /> �� � • . � �,,�"�,�u PORT C?F EVERETT . �wc. rvo. � <br /> � ��D y oFr y H. KUYPER AS NOTED : <br /> N ,�,.�� 0�9 DESIGNm BY: DATE NORTH i�ARlNR REDEVEtOPM�NT C�.3 <br /> D. YE AUGUST 4, Z006 CIP N0. <br /> "Q 728134th Street S�•Su�e 20D � " � . o o�„H BY: �,��K��: 1NfRASTRt1_CT11RE PHASE i 3-0-003-09 <br /> � Everett Was6ington 98ZQ4 °��'s�sr��0 W. CtRIDON PRWECT <br /> � P��r,wn sa2o5 0 B/4/O6 PERMR APPROVaL/CONS1RUCrON 8���� ?J�4� P���: ����� �ND GAS PLAN No. PD—NM-2005—Qfi . <br /> Ph:425 741-380(i 0 <br /> o (425)259-3164 � o�vwrs o��03�0� � �1�Tf-� STREET � �SH�,.No. $,� ���a3 <br /> JOB No. 21-04-075 �. �TE er �n5ior+ t�0. R'aE er rtEwspK <br />