1300 W MARINE VIEW DR 2006 Plans 2022-12-27 (3)
>
Address Records
>
W MARINE VIEW DR
>
1300
>
Plans
>
1300 W MARINE VIEW DR 2006 Plans 2022-12-27 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2022 3:35:28 PM
Creation date
5/15/2019 9:30:41 AM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1300
Permit
PW0610-040
Year
2006
Notes
NORTH MARINA REDEVELOPEMENT INFRASTRUCTURE PAHSE 1 CONFORMED SET
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
166
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEf3END: <br /> W WATER MAIN <br /> o I i <br /> Ca NATURAL GAS LINE <br /> I i - S� �-- PROPOSED STORM DRAIN LINE <br /> �` —SS PROPOSED SANITARY SEWER LINE <br /> � BACK OP WALK � --a-- pROPOSED POWER LINE <br /> I � — <br /> o I_ o V -T--- PROPOSED VERIZON TELEPHONE LINE <br /> N � W ---c-— PROPOSED COMCAST CABLE LINE <br /> � W -- - - <br /> = v� _ - EASEMENT LINE <br /> N <br /> � _ W DS/FS_ DOMESTIC WATER SERVICE & FIRE SERVICE <br /> �m s� Sp_�_ N N GATE VALVE <br /> � � � . N -mj o �S� S� so so ` so � V� BUTfERFLY VALVE <br /> 14 � � � SLOW-OFF ASSEMBLY <br /> -- -- ---- �4f90—����U� - - --- - �'�— - - - - � <br /> Q �W L'� � w � w w 240 LF 8"0..1-IDPE W w w W + 1R FIRE HYDR,4NT ASSEMBLY <br /> MI F=i TEE <br /> I ' N <br /> _ � � _. <br /> —— — —— — — — <br /> e o -- - - — - - -- - - — TI 90' ELBOW <br /> ao o �j— — <br /> �+. 6� � " � � THRU5T BLOCKING <br /> BACK OF WP,�K 2 � v� <br /> n N I n -1 W H RE�UCER <br /> z <br /> V 39 LF a fl 15' WATER EASEMENT = ^ CAP <br /> 8 � o � WM MEiER VAULT SEE Ot <br /> �,~j '' _� 3 PH 14 BACK OF WALK � 0 � � <br /> W � DS/FS 7 ( °' a � � �SDMH PROPOSED STORM DRAIN MANHOLE <br /> N WM � � <br /> 5 (I � `; I ■�g PROPOSED CATCH BASIN <br /> PROPOSED SANITARY SEWER MANHOLE <br /> N so SD �SD SD � �� 61 LF S"0 ' � a�'-r 1" AIR-VACUUM �� PROPOSED STORM DRAIN FILTER <br /> i 3RDAVENUE 31+00 I � 15 LF '1n HDPE J�� = VALVE ASSEMBLY <br /> -- - � <br /> I 0 PROPOSED VERIZON SERVICE VAULT <br /> o CAP AT TEE 2 w w � N � PROPOSED COMCAST SERVICE VAULT <br /> � � _ I-� OB VALVE & FlTfING LOCATION (SEE C9.1) <br /> M �� NOTES: CONSTRUCTION NOTES: v DEFLECT TO CROSS UNDER OTHER UTILITY <br /> � G G G G G WM �4 j 1. SEE TABLES ON SHEET C9.1 FOR FIRE Oj DOMESTIC WATER & e °"fl PROPOSED LIGHT POLE <br /> N 2$ �F ,,, HYDRANT, WATER MAIN FITTING AND VALVE, FIRE SERVICE, SEE <br /> AND DOMESTIC WATER AND FIRE SERVICE C9.11 <br /> W 9 LF " -� LOCATIONS. <br /> Z 15' WATER i� OZ CAP FOR FUTURE CONNECTION <br /> -� DS/FS 6 1 EASEMENT + 2. SEE SHEET C9.1 FOR STANDARD CITY THRUST BLOCKING <br /> V BACK OF WALK (-ryp) o DETAIL REFERENCE. <br /> Q z ; O3 FlRE HYDRANT ASSEMBLY <br /> � I ^ 3. NATURAL GAS LINE LOCATION IS SCHEMATIC. THRUST B O�CKINNOT USED THIS SHEET <br /> SEE PUGEf SOUND ENERGY DESIGN. <br /> O4 NOT USED THIS SHEEf <br /> 4. WHERE WATER AND NATURAL GAS O NOT USED THIS SHEEf <br /> INTERSECT EACH OTHER; DEFLECT WATER <br /> LINE UNDER NATURAL GAS LINE AT O NOT USED THIS SHEEf <br /> CROSSING, UNLESS NOTED OTHERWISE ON <br /> DRAWING. O7 NOT USED THIS SHEET <br /> 5. PROVIDE 12-INCH MINIMUM CLFARANCE <br /> BEfWEEN UTILITIES AT CROSSINGS, UNLESS OO �1) 8"4 GATE VALVE, FLxFL <br /> NOTED OTHERWISE. O9 NOT USED THIS SHEET �i <br /> 10 NOT USED THIS SHEEF <br /> � <br /> >> NOT USED THIS SHEET � �l5_ t 1 i �-l.iy,. �',. (o � � , ' <br /> a � �'{(" <br /> 12 NOT USEO THIS SHEET x � _�-"I a <br /> . l���--, LJ <br /> 13 NOT USED THIS SHEET =-€_ t . <br /> ,� � _..._ _ � <br /> rn 14 (1) 8"0 - 90' BEND. FL.xFL ';, ' � ` <br /> v � � � THRUST BLOCKWG �� I �� i�- � � <br /> .- � �,,_ �--..,�, � <br /> I :,`. <br /> v. m . - � � ,�r . .r.. .._ ._ . _.. <br /> � ��� <br /> � <br /> ::r.., <br /> , <br /> � KEY MAP ���;�'"'� � <br /> N : �:i�;l..� ., <br /> v � NOT TO SCALE � '��`� d_ ' � <br /> � Z �«�_- -..� �Ij <br /> o - - <br /> `c <br /> 0 <br /> U <br /> / <br /> � <br /> o �SCALE IN FEEf <br /> a NOTE: 'r ��—'i <br /> � 20 0 2o ao ADJUST SCALES A CORDINGLY. <br /> i <br /> � � � N•K � PROJECT-ENGINEER: SCALE P O R T O F �E V E R E T T DWG. NO. <br /> � � � � � • ' O��FWA Y,o� H. KUYPER AS NOTED CA.1O <br /> � PO�O y ,�: 'y °�'�"E°�: °"TE: NORTH MARINA REDEVELOPMENT <br /> D. YE AUGUST 4. 2006 CIP N0. <br /> 728134th Street SW�Suite 200 o�WN BY: �„E�KEo 8,.: INFRASTRUCTURE PHASE 1 3-0-003-09 <br /> � P.O. BOx 538 Everett.Washington 98204 03/16/07 CONFOR�AED SET ADDENDA 1-4 �88�oS`�o��'e w. c�R�ooN WATER AND GAS PLAN NoaEcr PD—NM-2005-06 <br /> NA <br /> o EVEREff,WA 98206 Ph:425 741-3800 � $�4/06 PERMIT APPROVAL/CONSTRUCTION , � �T �' PR°"�°�` 3 R D AV E N U E <br /> 425� T59-3764 N0. DATE BY REVISION NO. DA1E BY REVISION IXPIRES 03 03 9 SNEET N0. <br /> JOB No: 21-04-015 g¢ OF �� <br />