Code Reference <br /> 315.4 Outside storage <br /> 315.4 Outside storage.Outside storage of combustible materials shall not be located <br /> within 10 feet (3048 mm) of a lot line. <br /> Exceptions: <br /> 1. The separation distance is allowed to be reduced to 3 feet (914 mm) for storage not <br /> exceeding 6 feet (1829 mm) in height. <br /> 2. The separation distance is allowed to be reduced when the fire code official <br /> determines that no hazard to the adjoining property exists. <br /> 315.4.1 Storage beneath overhead projections from buildings.Where buildings are <br /> protected by automatic sprinklers, the outdoor storage, display and handling of <br /> combustible materials under eaves, canopies or other projections or overhangs is <br /> prohibited except where automatic sprinklers are installed under such eaves, canopies <br /> or other projections or overhangs. <br /> 315.4.2 Height.Storage in the open shall not exceed 20 feet (6096 mm) in height. <br /> SECTION 907 FIRE ALARM AND DETECTION SYSTEMS <br /> SECTION 907 <br /> FIRE ALARM AND DETECTION SYSTEMS <br /> [F] 907.1 General. <br /> This section covers the application, installation, performance and maintenance of fire <br /> alarm systems and their components. <br /> [F] 907.1.1 Construction documents. <br /> Construction documents for fire alarm systems shall be of sufficient clarity to indicate the <br /> location, nature and extent of the work proposed and show in detail that it will conform to <br /> the provisions of this code, the International Fire Code, and relevant laws, ordinances, <br /> rules and regulations, as determined by the fire code official. <br /> [F] 907.1.2 Fire alarm shop drawings. <br /> Shop drawings for fire alarm systems shall be submitted for review and approval prior to <br /> system installation, and shall include, but not be limited to, all of the following: <br /> 1. A floor plan that indicates the use of all rooms. <br /> 2. Locations of alarm-initiating devices. <br /> 3. Locations of alarm notification appliances, including candela ratings for visible alarm <br /> notification appliances. <br /> 4. Location of fire alarm control unit, transponders and notification power supplies. <br /> 5. Annunciators. <br /> 6. Power connection. <br /> 7. Battery calculations. <br /> 8. Conductor type and sizes. <br /> 9. Voltage drop calculations. <br /> 10. Manufacturers' data sheets indicating model numbers and listing information for <br /> equipment, devices and materials. <br /> 11. Details of ceiling height and construction. <br /> EVERETT FIRE DEPARTMENT• 2930 Wetmore AVE STE 7A • Everett WA 98201 • (425)257-8120 • Fax(425)257-8139 //" -----page 5 of 12 <br />