My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
915 WALL ST 2019-05-22
>
Address Records
>
WALL ST
>
915
>
915 WALL ST 2019-05-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2019 8:43:30 AM
Creation date
5/22/2019 8:43:09 AM
Metadata
Fields
Template:
Address Document
Street Name
WALL ST
Street Number
915
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
145
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
zones upon sprinkler waterflow. <br /> [F] 907.2.5 Group H. <br /> A manual fire alarm system that activates the occupant notification system in <br /> accordance withSection shall be installed in Group H-5 occupancies and in occupancies <br /> used for the manufacture of organic coatings. An automatic smoke detection system <br /> shall be installed for highly toxic gases, organic peroxides and oxidizers in accordance <br /> with Chapters 60, 62 and 63, respectively, of the International Fire Code. <br /> [F]907.2.6 Group I. A manual fire alarm system that activates the occupant notification <br /> system shall be installed in Group I occupancies. An automatic smoke detection system <br /> that notifies the occupant notification system shall be provided in accordance with <br /> Sections 907.2.6.1, 907.2.6.2, 907.2.6.3.3 and 907.2.6.4. <br /> Exceptions: <br /> 1. Manual fire alarm boxes in resident or patient sleeping areas of Group I-1 and 1-2 <br /> occupancies shall not be required at exits if located at nurses' control stations or other <br /> constantly attended staff locations, provided such stations are visible and continually <br /> accessible and that travel distances required in Section 907.4.2 are not exceeded. <br /> 2. Occupant notification systems are not required to be activated where private mode <br /> signaling installed in accordance with NFPA 72 is approved by the fire code official. <br /> [F] 907.2.6.1 Group I-1. <br /> In Group I-1 occupancies, an automatic smoke detection system shall be installed in <br /> corridors, waiting areas open to corridors and habitable spaces other than sleeping units <br /> and kitchens. The system shall be activated in accordance with Section. <br /> Exceptions: <br /> 1. Smoke detection in habitable spaces is not required where the facility is equipped <br /> throughout with an automatic sprinkler system installed in accordance with Section . <br /> 2. Smoke detection is not required for exterior balconies. <br /> [F] 907.2.6.1.1 Smoke alarms. <br /> Single- and multiple-station smoke alarms shall be installed in accordance with Section. <br /> [F] 907.2.6.2 Group 1-2. <br /> An automatic smoke detection system shall be installed in corridors in nursing homes, <br /> long-term care facilities, detoxification facilities and spaces permitted to be open to the <br /> corridors by Section . The system shall be activated in accordance with Section. <br /> Hospitals shall be equipped with smoke detection as required in Section . <br /> Exceptions: <br /> 1. Corridor smoke detection is not required in smoke compartments that contain <br /> sleeping units where such units are provided with smoke detectors that comply with UL <br /> 268. Such detectors shall provide a visual display on the corridor side of each sleeping <br /> unit and shall provide an audible and visual alarm at the care provider's station <br /> attending each unit. <br /> 2. Corridor smoke detection is not required in smoke compartments that contain <br /> sleeping units where sleeping unit doors are equipped with automatic door-closing <br /> devices with integral smoke detectors on the unit sides installed in accordance with their <br /> listing, provided that the integral detectors perform the required alerting <br /> EVERETT FIRE DEPARTMENT• 2930 Wetmore AVE STE 7A • Everett WA 98201 • (425)257-8120 • Fax(425)257-8139 Page 8 of 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.