Laserfiche WebLink
solar - • • Single Phase Inverter <br /> with HD-Wave Technology for North America <br /> SE3000H-US / SE3800H-US / SE5000H-US I <br /> SE6000H-US/ SE7600H-US/ SE10000H-US/ SE11400H-US <br /> SE3000H-USI SE3800H-US SE5000H-USITE6000H-US 1 SE7600H-USI SE10000H-USI SE11400H-US ' <br /> OUTPUT <br /> Rated AC Power Output 3000 3800 @ 240"1 5000 6000 @ 240"1 7600 10000 11400 1 VA <br /> 3300 a 208V 5000 a 208V <br /> Max.AC Power Output 3000 3800 @ 240"1 5000 6000 @ 240"1 7600 10000 11400 I VA <br /> 3300 p 208V 5000 a 208V <br /> AC Output Voltage Min.-Nom.-Max. - / - / - - - Vac <br /> (183-208-229) <br /> AC Output Voltage Min.-Nom.-Max. / / / / / / / Vac <br /> (211-240-264 <br /> AC Frequency(Nominal) 59.3-60-60.5(I Hz <br /> Maximum Continuous Output Current - 16 - 24 - - - A <br /> 208V <br /> Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A <br /> i240V <br /> GFDI Threshold 1 A <br /> Utility Monitoring,Islanding Protection, <br /> Country Configurable Thresholds _ Yes <br /> INPUT <br /> Maximum DC Power @240V Maximum DC Power @208V 4650 I 5510000 I 7750 I 9300 775011800 I 15500 I 17650 W <br /> Transformer-less,Ungrounded I Yes <br /> Maximum Input Voltage 480 Vdc <br /> Nominal DC Input Voltage 380 400 Vdc <br /> Maximum Input Current 208V - 9I - 13.5 - - I - <br /> Maximum Input Current @240V 8.5 10.5 13.5 16.5 20 27 30.5 Adc <br /> Max.Input Short Circuit Current 45 Adc <br /> Reverse-Polarity Protection Yes <br /> Ground-Fault Isolation Detection 6001<o Sensitivity <br /> Maximum Inverter Efficiency 99 I 99.2 % <br /> CEC Weighted Efficiency 99 % <br /> Nighttime Power Consumption <2.5 W <br /> ADDITIONAL FEATURES <br /> Supported Communication Interfaces R5485,Ethernet,ZigBee(optional),Cellular(optional) <br /> Revenue Grade Data.,ANSI C12.20 Optional1�1 <br /> Rapid Shutdown-NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect <br /> 690.12 <br /> STANDARD COMPLIANCE <br /> Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 <br /> Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) <br /> Emissions FCC Part 15 Class B <br /> INSTALLATION SPECIFICATIONS <br /> AC Output Conduit Size/AWG Range 3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG <br /> DC Input Conduit Size/#of Strings/ 3/4"minimum/1-3 strings/ <br /> AWG Range 3/4"minimum/1-2 strings/14-6 AWG 14-6 AWG <br /> Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.31540 x 370 in/mm <br /> x 185 <br /> Weight with Safety Switch 22/10 I 25.1/11.4 I 26.2/11.9 38.8/17.6 lb/kg <br /> Noise <25 <br /> I <50 dBA <br /> Cooling Natural Convection Natural convection <br /> Operating Temperature Range -13 to+140(-25 to+60131(-40"F(-40"C oetion)141 "Fr C <br /> Protection Rating NEMA 3R(Inverter with Safety Switch) <br /> I')For other regional settings please contact SolarEdge support <br /> 0 Revenue grade inverter P/N:SExxxxH-US000NNC2 <br /> 1 t For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf <br /> IW-40 version P/N:SExxxxH-US000NNU4 <br /> 6) <br /> IV RoHS <br /> ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE.the SolarEcige logo,OPTIMIZED BY SOLAREDGE <br /> are trademarks or registered trademarks of SolarEdge Technologies.Inc.All other trademarks mentioned herein <br /> are trademarks of their respective owners.Date:07/2018,,N01/ENG NAM.Subject to change without notice. <br />