SCOPE OF WORK GENERAL NOTES: r ,o-:- . Sri L°tEnergy Today Inc. <br /> PHOTOVOLTAIC SYSTEM SUMMARY 1. AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL DE-ENERGIZE ITS OUTPUT TO THE SOL AR <br /> CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN • <br /> SYSTEM SIZE:DC STC-6.00 KW THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED.(NEC 690361). a,. p,H <br /> M <br /> 2. ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING SHALL BE RAIN TIGHT THREAD-LESS COMPRESSION TYPE. ..r. • 7 `C - <br /> MODULES:(20)iTEK ENERGY T300-SE MODULE 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. - -• •:; ,- « � �"!, <br /> MODULE MX POWER(P/MAX):300W 4. NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS, - - - 1001 Cooper Point Rd SW, <br /> INVERTER:(11)APS-YC500A PANEL BOARDS.DISCONNECTING SWITCHES,TERMINAL CABINETS,ETC.ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE Suite 140-290 <br /> MICROINVERTER OF SUFFICIENT CAPACITY TO WITHSTAND THE WEATHER. • < Olympia,WA 98502 <br /> ARRAY TILT:20° 5. JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF. k, 1 Phone:888-405-8689 <br /> AZIMUTH:180°/270° 6. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION BOX/COMBINER BOXES PER ;' Fax:855.350.9430 <br /> ELECTRICAL INFORMATION APPROPRIATE NEC REQUIREMENTS. ssl '' su ort smartens <br /> 7. SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS. . xy PP @ rgytoday.net <br /> COUNTY:TYSNOHOMISHANY: COUNTY <br /> UTILITY COMPANY:SNOPUD 8. WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS.FIELD APPLIED PROTECTIVE COATINGS ARE �_. �4Sr 6 �Y <br /> 1�. - REVISIONS <br /> MAIN SERVICE AMPERAGE:200A NOT ACCEPTABLE. --- <br /> 9. JUNCTION,PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING CONTAINED IN THEM CAN �,5k - DESCRIPTION Ox/n BEE <br /> BUILDING INFORMATION:ONE STORY HOUSE BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S)SECURED BY REMOVABLE FASTENERS AND CONNECTED ' `J INITIAL 63-154018 00 <br /> ROOF:METAL SHINGLE BY A FLEXIBLE WIRING SYSTEM.(NEC 690.34). <br /> NUMBER OF LAYERS:01 10. IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM,THE POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH .. , <br /> ANNUAL AVERAGE WIND SPEED:110 MPH JUNCTION BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE " " <br /> GROUND SNOW LOAD:15 PSF WARNING-ELECTRIC SHOCK HAZARD.THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE - ard <br /> Signature with Seams <br /> UNGROUNDED BUT MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND FAULTS'(NEC _hM -. M <br /> 690.35(F)). -,1 <br /> 1 <br /> 11. ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM ANY PHYSICAL :; <br /> CODE SUMMARY DAMAGE. <br /> 2015 WASHINGTON STATE BUILDING CODE(2015 IBC) 12. ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. f .. j, ./• r yy-,: <br /> 2015 WASHINGTON STATE ENERGY CODE(2015 IECC) 13. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. • , <br /> 2015 WASHINGTON STATE RESIDENTIAL CODE 14. ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER. ' �• f •i'16 �} •�, ' <br /> (2015 INTERNATIONAL RESIDENTIAL CODE WASHINGTON 15. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION,COMMISSIONING AND ACCEPTANCE -' 1 i <br /> AMENDMENTS 2014 WAC51-51-2300 SECTION M2302) WITH THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS NEEDED. +++ff��� - ," '+1 5 • '.Yy., <br /> 2017 WAC 296468(2017 NEC) 16. DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BEAT THE OPTION OF THE CONTRACTOR UNLESS OTHERWISE ,.., •+ _Z. 'r • 4. • <br /> 2015 WASHINGTON STATE MECHANICAL CODE(2015 UMC) NOTED AND SHALL BE COORDINATED WITH OTHER TRADE. .. - -1 • '•-'' 4T <br /> 1 2015 WASHINGTON STATE PLUMBING CODE(2015 UPC) 17. IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN,THE CONTRACTOR SHALL NOTIFY ELECTRICAL ENGINEER TO VALIDATE `" 'S� 11 PROJECT NAME 8 ADDRESS <br /> 9 2015 WASHINGTON STATE FIRE CODE(2015 IFC) THE WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. <br /> 18. WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT,ARISES ON THE DRAWINGS OR SPECIFICATIONS,THE CONTRACTOR SHALL 1 AERIAL VIEW <br /> BE RESPONSIBLE FOR PROVIDING AND INSTALUNG ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED <br /> SHEET INDEX <br /> ON <br /> THE <br /> EDRAWINED BY GS <br /> OR INT THE <br /> SPECIFICAINEERTIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM PV-0 SCALE.NTS <br /> 19. ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS,ETC.SHALL BE HANDED OVER TO THE OWNER'S <br /> V-0 COVER SHEET REPRESENTATIVE AT THE COMPLETION OR WORK. Z <br /> V-1 PLOT PLAN WITH ROOF PLANS <br /> H 20. ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. <br /> V-2 ROOF PLAN WITH MODULES 21. THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE WITH THE•SMACNA'-GUIDLINES FOR t;' 't-"-' •+ 7r+ _ <br /> V-3 ATTACHMENT DETAIL1 ' I. j ' <br /> 1- a <br /> V-4 ELECTRICAL LINE DIAGRAM SEISMICLOFHE LISTEDDS OF MECHANICAL RE UI SYSTEMS AND PLUMINGISMICLATERAL PIPING FORCE F I <br /> 22. ALL OF THE SYSTEMS REQUIRED THAT THE SEISMIC FORCE F INCLUDING CONSIDERATION OF a^P AND MP BE f1i<y'1 - '" j 1-- <br /> w <br /> V-5 PLACARDS DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE SPACING CAN BE CALCULATED.THE DISTRICT STRUCTURAL ENGINEER x 7 k L ~ M <br /> V-60 MANUFACTURER SPEC SHEET CAN APPROVE THE SEISMIC LATERAL FORCE DETERMINATION. t `A' y i g y r W e N <br /> 23. A COPY OF THE CHOSEN BRACING SYSTEM(S)INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB SITE PRIOR TO STARTING THE - s 1 "` h' <br /> INSTALLING OF HANGERS AND/OR BRACES. • P _�✓ r r �' ��" :T1 " •t a -CONCMD <br /> 24. WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON-PRESTRESSED REINFORCED CONCRETE.USE la o,,:',/r.a..4k„,-,. ..,,,.-ames,•",,. 1,.;- <br /> , ,1 a /A. r i-: W < Q <br /> CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE REINFORCED BARS.WHEN INSTALLING THEM INTO EXISTING I fu. ,S -.At LL <br /> PRE-STRESSED CONCRETE TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION.EXERCISE EXTREME CARE f Z� ,�,'.' I" ,' jI .�, 3 S r'-^ - -3 W <br /> AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION.MAINTAIN A MINIMUM CLEARANCE OF ONE INCH •p`}• - it%M' f p. y i`K' M <br /> BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. P � ` yy qr�5�- ti 3/ 4 •'j -'+, (jj <br /> 25. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE 0.:6;1V 4+-s F°1 & "y UJ MO z <br /> MAINTAINED IN ACCORDANCE WITH NEC 110.26. p 1'Y#� '',Ni �, i f{ JN ,- tx O <br /> 26. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC 300.601,310.8 D. �Q „�Y.} C t 1'• LJ� '- L1J <br /> 27. GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM.(NEC ,r <br /> p1�,, € <br /> 250.97). .: 7',,, a Q <br /> 28. THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF SMALLER THAN 96 COPPER WIRE.(NEC £ t sn I <br /> W <br /> 250.64 B). • _ <br /> 29. GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTEDa � ,�•� ',' ' a.-- U <br /> EQUIPMENT.(NEC 250.64 C). m}�t Yl t,1. <br /> 30. RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END.(NEC 250.64(E). @� F "f=„,....;,....".,,, <br /> r_,,e 11 , 4 "�� IE-•'!i- <br /> 31. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION.A SIGN WILL BE PROVIDED - 1 ra.Y `^, # ...,:j'0" n <br /> WARNING OF THE HAZARD PER NEC 690 17 34.EACH UNGROUNDED CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BEA + �' <br /> IDENTIFIED PER PHASE AND SYSTEM PER NEC210.5. _�-,r c r 1a "7, J• ',�-��.; <br /> 32. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97&250.92(B)&LAMC 93.250.97. 'O4 ..- 1 9-' \ 1 <br /> 33. DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST <br /> ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31(E),LAMC 93.690.31(E). SHEET NAME <br /> 34. ALL METALUC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS(CONDUIT,JUNCTION&PULL BOXES,RACEWAY, <br /> ETC)SL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S INSTALLATINSTRUCTIONS LAMC 93.690.110.3&93.110.3(B). <br /> ON <br /> 35. SCREWSS,,NUTS, OTS&WASHERS THAT ATTACH EQUIPMENT GROUNDING I UGSSHALL BESTAINLESS STEEL LAMC 93.110.3(B). 2 VICINITY MAP COVER SHEET <br /> 36. NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE <br /> DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. PV-0 SCALE:NTS SHEET SIZE <br /> 37. ALL FIELD INSTALLED JUNCTION,PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY <br /> OR BY DISPLACEMENT OF A MODULE(S)OR PANEL(S)SECURED BY REMOVABLE FASTENERS. ANSI B <br /> 38. REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN <br /> THE GROUNDING HOV CONDUCTOR AND THE PHOTOVOLTAIC VOLTAIC <br /> O OUTPUT ERGROUNDED CONDUCTOR.O. n ^X 7°1 <br /> 39. THE ROOF MOUNTED PHOTOVOLTAIC MODULES,PANELS,OR SOLAR VOLTAIC ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR soul <br /> BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING ROOF-COVERING MATERIAL. SHEET NUMBER <br /> 40. ALL ROOF MOUNTED CONDUIT WILL BE A MINIMUM 6'OFF THE ROOF SURFACE. <br /> PV-0 <br /> OR 022098 17 . <br /> rvicesio '1-oO3Permit Services <br />