Laserfiche WebLink
Prescriptive Path, pg. 2 ENV-PRESCRIPTIVE <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: Enhanced Servicess Facility(ESF)+Retail Date 10/04/2017 <br /> Fenestration Area as%gross above-grade wall area 19.2% Max.Target: 30.0% For Building Department Use <br /> Skylight Area as%gross roof area Max.Target: 3.0% <br /> If vertical fenestration or skylight area exceeds maximum allowed per C402.4.1,then the project must comply <br /> via Component Performance and provide ENV-UA and ENV-SHGC forms. <br /> R-Value Method for U-Factor/F-Factor Method for <br /> Building Component <br /> Prescriptive Compliance Prescriptive Compliance <br /> Perim.Ins. Full Slab CI <br /> Provide plan/detail#of assembly and description R-Value I R-Value F-Factor F-Factor Source10 <br /> iii F1/A603 SLAB ON GRADE 10.0 <br /> -o a <br /> E L <br /> m c " i' <br /> c <br /> 4 0 F1/A603 SLAB ON GRADE <br /> Jo 0 <br /> f0a5 2"(R-10)RIGID INSULATION UNDER SLAB 10.0 10.0 6 k? <br /> i-n = <br /> Ins. Assembly <br /> Provide ID from door schedule and description R-Value U-Factor U-Factor Sourcell <br /> 0) <br /> ` C <br /> °o ,c A/A705&H/A705 0.370 C402.1.4 <br /> O .... <br /> a <br /> o- <br /> a• a <br /> O 0 <br /> Solar Heat Gain Coefficient(SHGC) U-Factor for Prescriptive Compliance <br /> Projection Orientation <br /> Factor(PF) (N or Assembly Assembly <br /> Provide ID from window schedule and description if applicable12 SEW)13 SHGC14 U-Factor U-Factor Source74 <br /> �a FG1/A705 0.37 N 0.58 0.30 C402.4 <br /> 2 FG2/A705 0.44 SEW 0.48 0.30 C402.4 <br /> a FG3/A705 0.41 N 0.58 0.30 C402.4 <br /> Z FG4/A705 0.44 SEW 0.48 0.30 C402.4 <br /> SF2/A705 0.74 SEW 0.40 0.38 C402.4 <br /> c <br /> • 0 SF4/A705 0.74 SEW 0.40 0.38 C402.4 <br /> CO w SF8/A705 SEW 0.40 0.38 C402.4 <br /> c• i SF9/A705 0.36 SEW 0.48 0.38 C402.4 <br /> a <br /> 0 <br /> m o SF3,SF5,SF6,SF7 /A705 0.74 SEW 0.64 0.40 C402.4 <br /> Ta <br /> a) <br /> 2 <br /> S SF1/A705 0.66 SEW 0.64 0.60 C402.4 <br /> C <br /> a <br /> 2 <br /> co 2 <br /> L a <br /> 01 >, <br /> >, H <br /> Y = <br /> r/1 Q <br /> Note 1-Insulation that is continuous except for fasteners may be entered here if the cross-sectional area of metal penetration through otherwise <br /> continuous insulation is less than 0.12%. <br /> Note 2-Alternate prescriptive continuous insulation R-values per Table C402.1.4,Footnote F may be used if the cross sectional area of metal <br /> penetrations exceeds 0.04%but is less than 0.12%.Calculations are required to use these alternate R-values. <br /> Note 3-Opaque assembly U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. Specify the <br /> table number or calculation page number. III <br /> Note 4-Thermal spacer blocking and liner system are required for prescriptive R-Value compliance in metal building roof assemblies. <br /> Note 5-Intermediate framing is required for prescriptive R-Value compliance in wood-framed wall assemblies. <br /> Note 6-Proposed CMU mass walls in non-Group R that meet Table C402.1.4 Footnote D requirements can enter the target prescriptive <br /> U-value of 0.104. <br /> Note 7-Mass transfer slab edges must be covered with an assembly having an overal U-factor of 0.2. <br /> Note 8-Refer to Table C402.1.3,Footnote E for prescriptive R-Value requirement for steel floor joist assemblies. <br /> Note 9 -Prescriptive slab-on-grade insulation shall extend from top of slab to minimum length per an approved method as defined in C402.2.6. <br /> Note 10-Slab-on-grade F-Factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1. <br /> Note 11-Opaque door U-factors shall come from Appendix A or calculated per approved method as specified in C402.1.5.1.A door is defined as <br /> opaque if less than 50%of the door area has glazing. <br /> Note 12-Refer to Equation C4-6 Projection Factor Calculation. <br /> Note 13-N=Oriented within 45 degrees of true north,SEW=All other orientations. <br /> Note 14-Fenestration assembly U-Factor and SHGC shall be the manufacturer's NFRC product rating,which includes the glazing and frame,or <br />