Laserfiche WebLink
Vertical Fenestration Target Area Adjustment Calculations <br /> If vertical fenestration area exceeds maximum allowed per Section C402.4.1,then Target Area Adjustment of all applicable envelope elements is <br /> required. This worksheet automatically calculates these adjustments and updates target areas in the ENV-UA and ENV-SHGC worksheets. Information <br /> shown in this worksheet is for reference only and is write protected.Submit this Target Area Adjustment form with ENV-UA and ENV-SHGC forms. <br /> VF=Vertical fenestration NW=Net above grade wall(excludes fenestration and doors.) <br /> DR=Opaque doors Gross Exterior Above-Grade Wall Area=VF+NW+DR <br /> AG=Above-grade <br /> Proposed Areas , <br /> �\ ' ' OT APPLICABLE <br /> Vertical Fenestration-> VF= <br /> Opaque-> NW= DR= <br /> Gross Exterior Max Vert.Fen.% Maximum Target <br /> AG Wall Area (C402.3.1) Vert.Fen.Area <br /> X 30.0% - 100 = <br /> Total Vertical Delta Vertical Excess Vertical <br /> Fenestration Maximum Target Fenestration 0 Fenestration <br /> II greater = <br /> y / Multiplier applied to all <br /> Total Vertical Excess Vertical / Target Vertical Total Vertical Proposed Vertical <br /> Fenestration Fenestration Fenestration Fenestration Target VF Multiplier Fenestration Areas to <br /> calculate Target Vertical <br /> — <br /> — - — Fenestration Area <br /> Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Multiplier applied to all <br /> + = -7- = Proposed Opaque Above- <br /> Grade Wall Areas to <br /> Target Areas - UA calculate Target Above- <br /> Commercial Grade Wall Area <br /> Vertical Fenestration Proposed Area Target VF Mult. ..... Target Area <br /> Non-metal frame X <br /> Metal frame,fixed = <br /> X <br /> Metal frame,operable X = <br /> Metal frame,entrance door X Target areas in shaded <br /> Above-grade Wall Proposed Area Target Net Wall Mult. Target Area boxes are applied to <br /> Steel Frame X = target areas on ENV-UA <br /> Metal Building X <br /> Wood/Other frame X <br /> Mass X — <br /> Mass Transfer Deck X = <br /> Group R Mass X = <br /> Sum of target above-grade <br /> Sum of Proposed Sum of Target ';::::',;'..,•' wall and vertical <br /> fenestration areas are <br /> Target Areas -SHGC x A calculated to equal the <br /> Non-North Vertical Fenestration Proposed Area Target VF Mult. Target Area <br /> PF<0.2 X — Cs ...v. <br /> 0.2<_PF<0.5 X = 162;; . <br /> PF z 0.5 X = <br /> g tpa11 , 1 SHGC target areas in <br /> shaded boxes are applied <br /> North Vertical Fenestration to target areas on ENV- <br /> PF _ <br /> <0.2 X m. r' !• SHGC <br /> 0.25 PF<0.5 X — g .reee,eiaNt: <br /> PF_>0.5 X = iffrngigeg, <br />