My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
>
Address Records
>
EVERGREEN WAY
>
6502
>
ENHANCED SERVICE FACILITIES
>
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 9:13:55 AM
Creation date
5/29/2019 3:24:21 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6502
Tenant Name
ENHANCED SERVICE FACILITIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
22122 20th Ave SE,Suite 161 <br /> PRESSLER. Bothell,Washington 98021 <br /> E2ngin rin .Inc (425)485-3002 <br /> (425)485-8114 Fax <br /> Mechanical.and Electrical Engineering Consultants <br /> • <br /> To: City of Everett,Mechanical Inspector <br /> Attention: Darold Walden <br /> Copy to: Todd Madison <br /> Regarding: Enhanced Services Facilities (ESF) kitchen hood makeup air <br /> Project address: 6504 Evergreen Way, Everett, WA 98203 <br /> Dear Sir, <br /> The installed kitchen hood at this project is a 48" stainless steel canopy type with 3 <br /> speeds of control options and up to 600 cfm exhaust airflow. Makeup air for this hood is <br /> provided via the HVAC system that is designed and intended to operate for 24 hours a <br /> day and 7 days a week, due to the nature of the occupancy. Within the kitchen space, <br /> the HVAC system constantly supplies 585 cfm of conditioned air. When the kitchen <br /> hood is operating this supply air will become makeup air and be exhausted out of the <br /> hood and the room will be under a slight negative pressure. When the hood is not <br /> operating, the supply air will provide positive pressure, with return air taken from the <br /> neighboring space. <br /> The HVAC systems are equipped with 100% outside air economizers. For this reason, <br /> the facility will most often have positive pressurization in the common areas. The <br /> mechanical design includes barometric relief, provided via relief air hoods at the roof. <br /> When not in economizer cooling mode, the HVAC systems are designed to bring in a <br /> minimum amount of fresh outside air to each indoor fan coil unit. The minimum outside <br /> air amount is sufficient to address the makeup air needed as well. <br /> Feel free to give me a call if you have any further questions or concerns. Thank you! <br /> Dawne Herrick, PE, LEED AP® <br /> Senior Mechanical Project Manager <br /> Pressler Engineering, Inc. <br /> "Excellence in Mechanical & Electrical Engineering" <br /> ESF in Everett <br /> Project Memorandum <br /> June 28,2018 <br />
The URL can be used to link to this page
Your browser does not support the video tag.