My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
>
Address Records
>
EVERGREEN WAY
>
6502
>
ENHANCED SERVICE FACILITIES
>
6502 EVERGREEN WAY ENHANCED SERVICE FACILITIES 2020-01-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/21/2020 9:13:55 AM
Creation date
5/29/2019 3:24:21 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
6502
Tenant Name
ENHANCED SERVICE FACILITIES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
541
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Comment#6. Reply: 1 HR enclosure adjusted on the plans. Refer to sheet A005. <br /> Comment#7. Reply: Refer to R1/A605 1-HR ceiling assembly updated to meet requirements. <br /> Comment#8. Reply: Refer to Section D/A403, ceiling in rm. 117 is called out as R1/A605 1-HR <br /> assembly. <br /> Comment#9. Reply: Refer to A203 +A205: Shafts are called out as W6 wall type (Shaft wall <br /> 1-HR) and continue to the underside of the roof sheathing. <br /> Comment#10a. Reply: Refer to mechanical response letter. <br /> Comment#10b/c. Reply: Refer to A205 callouts for W1 wall type (Shaft wall 1-HR)for the dryer <br /> vent and kitchen hood vent. <br /> Comment#11. Reply: Refer to specs. Residential cooking appliance substituted for use in <br /> kitchen and a type-1 hood is not required for this application. <br /> Comment#12. Reply: Refer to specs: two residential type dishwashers are substituted for use in <br /> kitchen and a hood is not required. <br /> Egress <br /> Comment#1a. Reply: The rooms mentioned are removes and are part of the corridor. Also <br /> added two set of double doors in the corridor adjacent to the lobby on the first floor. <br /> Comment#1b. Reply: Doors and windows rated 1-HR. <br /> Comment#1c. Reply: Refer to A203, glazing removed from rms 101, 111 and 116. Remaining <br /> windows and doors in the corridor are rated 1-HR. <br /> Comment#2. Reply: Refer to A203 courtyard. Ramps and ramp slopes are identified on the <br /> plans. <br /> Comment#3. Reply: refer to 4/A423. Soffit call out as ceiling type R1 and soffit as W1 1-HR <br /> construction. <br /> Comment#4. Reply: Glass Guard is no longer used on this project. <br /> Accessibility <br /> Comment#1. Reply: Refer to 4/A423 shower substituted for tub. Grab bars shown in 8/A523 <br /> and 20/A523. <br /> Comment#2 & 3. Reply: Refer to 5/A523 and 17/A523 for shower seat and grab bar locations. <br /> Energy <br /> Project No.3014594 and 6324483 Page 2 of 3 Bazan Architects <br />
The URL can be used to link to this page
Your browser does not support the video tag.