My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
>
Address Records
>
GRAND AVE
>
2900
>
PAGODA VILLAGE
>
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 8:56:50 AM
Creation date
5/30/2019 7:21:35 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
PAGODA VILLAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
515
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Physical ite <br /> Properties cf r ACRYLIC SHEET <br /> ASTM Typical Value <br /> Property(a) Method (.236"Thickness)(b) <br /> Mechanical Specific Gravity D 792 1.19 <br /> Tensile Strength D 638 10,000 psi (69 M Pa) <br /> Elongation, Rupture 4.2% <br /> Modulus of Elasticity 400,000 psi (2800 M Pa) <br /> Flexural Strength (Rupture) D 790 16,500 psi (114 M Pa) <br /> Modulus of Elasticity 475,000 psi (3300 M Pa) <br /> Compressive Strength (Yield) D 695 18,000 psi (124 M Pa) <br /> Modulus of Elasticity 430,000 psi (2960 M Pa) <br /> Shear Strength D732 9,000 psi (62 M Pa) <br /> Impact Strength 0.4 ft. lbs/in.of notch <br /> Izod Milled Notch D 256 (21.6 J/m of notch) <br /> Rockwell Hardness D785 M-94 <br /> Barcol Hardness D 2583 49 <br /> Residual Shrinkage(c) (Internal Strain) D 702 2% <br /> Optical Refractive Index D 542 1.49 <br /> (Clear Material) Light Transmission,Total D 1003 92% <br /> UV Transmission 0 at 320 nanometers <br /> Haze Less than 1% <br /> Thermal Forming Temperature - 340-380°F (170-190°C) <br /> Deflection Temperature <br /> under load,264 psi D 648 210°F (99°C) <br /> Vicat Softening Point D 1525 239°F (115°C) <br /> Maximum Recommended Continuous <br /> Service Tern erature - 180°F (d) (82°C) <br /> Coefficient of Linear Thermal Expansion D 696 0.000040 in/in-°F (0.000072 m/m-°C) <br /> Coefficient of 1.3 BTU/(Hr) (Sq. Ft.) (°F/in.) <br /> Thermal Conductivity (k-Factor) Cenco-Fitch (0.19 w/m•K) <br /> Flammability (Burning Rate 1.2 in/min. <br /> 3mm thickness) D 635 (30.5 mm/min.) <br /> Self-Ignition Temperature D 1929 910°F(490°C) <br /> Specific Heat @ 77°F - 0.35 BTU/(lb.) (°F) <br /> (1470 J/Kg•k) <br /> Smoke Density Rating 3mm thickness) D 2843 11.4% <br /> Electrical Dielectric Strength <br /> Short Time (0.1 25"-thickness) D 149 430 volts/mil (17 KV/mm) <br /> Dielectric Constant <br /> 60 Hertz D 150 3.5 <br /> 1,000 Hertz 3.2 <br /> 1,000,000 Hertz 2.7 <br /> Dissipation Factor <br /> 60 Hertz D 150 0.06 <br /> 1,000 Hertz 0.04 <br /> 1,000,000 Hertz 0.02 <br /> Volume Resistivity D 257 1.6 x 10'5ohm-cm <br /> Surface Resistivity D 257 1.9 X 10t5ohms <br /> Water 24 hrs @ 73°F D 570 0.2% <br /> Absorption Weight Gain during Immersion0.2% <br /> Soluble Matter Lost 0.0% <br /> Water Absorbed 0.2% <br /> Dimensional Change during Immersion 0.2% <br /> Long Term Weight Gain during Immersion D 570 <br /> Water 7 days 0.5% <br /> Absorption 14 days 0.6% <br /> 21 days 0.8% <br /> 35 days 1.0% <br /> 48 days 1.1% <br /> Odor - None <br /> Taste - None <br /> NOTES:(a)Typical values:should not be used for specification purposes. V� <br /> (b)Values shown are for 6mm thickness unless noted otherwise.Some values will change with thickness. _ i <br /> (c)Difference in length and width,as measured at room temperature,before and after heating above 300°F .� 4 <br /> i (d)It is recommended that temperatures not exceed 180°F for continuous service,or 200°F for short,intermittent use. ) <br />
The URL can be used to link to this page
Your browser does not support the video tag.