My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
>
Address Records
>
GRAND AVE
>
2900
>
PAGODA VILLAGE
>
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 8:56:50 AM
Creation date
5/30/2019 7:21:35 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
PAGODA VILLAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
515
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
8. The location of Fire Department connections (FDC)and post indicator valves (PIV) shall be determined <br /> by the Fire Code Official. If immediate outside mandoor access is available to the sprinkler valves <br /> (risers),a PN will not be required. <br /> Place FDC on the Hewitt/Grand Avenue corner of the building. <br /> 9. Fire Hydrants-Locations as planned are acceptable. <br /> 10: Portable Fire Protection-A portable fire extinguisher with a minimum U.L.rating of <br /> 2-A:10-B:C shall be provided within 75 feet of travel on all floors of each building during construction <br /> and prior to occupancy. <br /> 11. Kitchens-Install a K-type fire extinguisher within 30 feet of the grill and deep fryers. <br /> 12. Garages - Install a portable fire extinguisher with a minimum U.L. rating of 2-A:40-B:C within 30 feet <br /> travel distance of all portions of this building. <br /> 13. Fire Alarm System - An approved automatic fire detection system shall be provided as required by City <br /> Ordinance No.3021-07,Chapter 16.76,of the Everett Municipal Code. <br /> Plans for such system shall be submitted to the Fire Code Official for review and approval prior to <br /> installation. Submittal shall include cut sheets of all equipment intended for use. Appropriate trip tests, <br /> witnessed by a Fire Department Inspector, shall be performed, along with a certificate of completion, <br /> prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Chapter 72. Installation of fire alarm <br /> components, including basic wiring, may not commence before plans are approved by the Fire <br /> Department Plan Reviewer. Fire alarm drawings must be professionally rendered, in sufficient detail, <br /> and must be internally consistent. Riser diagrams must match installation plans and load calculations. <br /> Components must be listed and approved for use together. Changes to plans must include new drawings <br /> and calculations and must be approved by the Fire Department Plan Reviewer prior to installation. Fire <br /> alarm installation is subject to field inspection by a Fire Department Inspector. An approved set of plans <br /> and the Engineering& Public Services Department electrical permit must be present for any installation <br /> inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Engineering &Public Services <br /> Department. Electrical inspections and approval are required prior to calling for acceptance tests. Call <br /> (425)257-8810 for permit information. <br /> The absence of working phone lines for the alarm system will be cause for postponing Fire <br /> Department inspection and testing and shall result in denial of occupancy. <br /> A copy of NFPA 72 Record of Completion form must be filled out prior to final occupancy (NFPA 72, <br /> 2007 Edition,page 72-33). <br /> Call for design requirements per Authority Having Jurisdiction. Automatic smoke detection is <br /> required. <br /> 14. Install a standby power system in compliance with the requirements of paragraph 604.2.14.1 of the 2009 <br /> International Fire Code. <br /> 15. For buildings with two or more floors, including sub-floors, the alarm system must call point-by-point <br /> reporting to an alarm center. <br />
The URL can be used to link to this page
Your browser does not support the video tag.