My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
>
Address Records
>
GRAND AVE
>
2900
>
PAGODA VILLAGE
>
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 8:56:50 AM
Creation date
5/30/2019 7:21:35 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
PAGODA VILLAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
515
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
31. Grade-Fire apparatus access roads shall not exceed 10%in grade. <br /> 32. Commercial and industrial buildings exceeding 30 feet or three stories in height shall have at least two <br /> means of fire apparatus access for each structure. <br /> 33. Buildings or portions of buildings or facilities exceeding 30 feet in height above the Iowest level of fire <br /> department vehicle access shall be provided with approved fire apparatus access roads capable of <br /> accommodating fire department aerial apparatus. Overhead utility and power lines shall not be located <br /> within the aerial fire apparatus access roadway. <br /> 34. Fire apparatus roads shall have a minimum unobstructed width of 26 feet in the immediate vicinity of any <br /> building or portion of building more than 30 feet in height. At least one of the required access routes <br /> shall be located within a minimum of 15 feet and a maximum of 30 feet from the buildine and shall <br /> be positioned parallel to one entire side of the building. <br /> 35. Multi-family residential projects having more than 100 dwelling units shall be equipped throughout with <br /> two separate and approved fire apparatus access roads. Exception: Projects having up to 200 dwelling <br /> units may have a single approved fire apparatus access road when ALL buildings, including <br /> nonresidential occupancies,are equipped throughout with approved automatic sprinkler systems. <br /> 36. Where elevators are provided in buildings, at least one elevator shall be provided for fire department <br /> emergency access to all floors. The elevator car shall be of such a size and arrangement to accommodate <br /> a 24-inch by 84-inch ambulance stretcher in the horizontal, open position and shall be identified by the <br /> international symbol for emergency medical services (star of life). The symbol shall not be less than 3 <br /> inches high and shall be placed inside on both sides of the hoistway door frame. <br /> Exception: If all stories within the building have direct, accessible egress to grade (EMC 16.01, Section <br /> V). <br /> 37. A building footprint and lot layout for this project shall be provided to the Fire MarshaPs Office on <br /> CD/DVD. <br /> Hotel <br /> 1. Access-The International Fire Code requires that all new structures shall provide Fire Department access <br /> roads to within 150 feet exterior walking distance of all portions of the ground floor. Fire Department <br /> access roads (Fire Lanes) shall provide a minimum of 20 feet in width of unobstructed, paved driving <br /> surface,exclusive of shoulders,with a minimum clear height of 13'6". Inside turn radii must be 35 feet. <br /> Outside turn radii must be 55 feet. Slope approach and departure angles must not exceed S <br /> degrees. Fire lane grade must not exceed 15 percent. Fire lane construction must comply with <br /> AASHTO H30 load capacity(74,000 gvw). Fire Lanes will be posted and maintained as required by the <br /> Fire Department. Unorthodox access which meets code requirements but is too unusual for crews <br /> will not be allowed. <br /> 2. Buildings greater than 30 feet high require ladder apparatus access in accordance with the 2009 <br /> International Fire Code, Section D105. The unobstructed width of the access in the immediate vicinity of <br /> the building shall be 26 feet. At least one of the required access routes shall be located within a minimum <br /> of 15 feet and a maximum of 30 feet from the building and shall be positioned parallel to one entire side <br /> of the building. <br /> 3. Access-O.K.as shown on the site plan reviewed. <br /> 4. Two(2)Knox Boxes are required--entry;east stairway at alley. <br /> 11//51) <br />
The URL can be used to link to this page
Your browser does not support the video tag.