12. Kitchens-Install a K-type fire extinguisher within 30 feet of the grill and deep flyers. <br /> 13. Garages - Install a portable fire extinguisher with a minimum U.L. rating of 2-A:40-B:C within 30 feet <br /> travel distance of all portions of this building. <br /> 14. Fire Alarm System -An approved automatic fire detection system shall be provided as required by City <br /> Ordinance No. 3021-07,Chapter 16.76,of the Everett Municipal Code. <br /> Plans for such system shall be submitted to the Fire Code Official for review and approval prior to <br /> installation. Submittal shall include cut sheets of all equipment intended for use. Appropriate trip tests, <br /> witnessed by a Fire Department Inspector, shall be performed, along with a certificate of completion, <br /> prior to final acceptance of the system. <br /> Fire alarm systems shall be installed according to NFPA Chapter 72. Installation of fire alarm <br /> components, including basic wiring, may not commence before plans are approved by the Fire <br /> Department Plan Reviewer. Fire alarm drawings must be professionally rendered, in sufficient detail, <br /> and must be internally consistent. Riser diagrams must match installation plans and load calculations. <br /> Components must be listed and approved for use together. Changes to plans must include new drawings <br /> and calculations and must be approved by the Fire Department Plan Reviewer prior to installation. Fire <br /> alarm installation is subject to field inspection by a Fire Department Inspector. An approved set of plans <br /> and the Engineering&Public Services Department electrical permit must be present for any installation <br /> inspection. <br /> Fire alarm systems shall be installed under permit of the City of Everett Engineering &Public Services <br /> Department. Electrical inspections and approval are required prior to calling for acceptance tests. Call <br /> (425)257-8810 for permit information. <br /> The absence of working phone lines for the alarm system will be cause for postponing Fire <br /> Department inspection and testing and shall result in denial of occupancy. <br /> A copy of NFPA 72 Record of Completion form must be filled out prior to final occupancy (NFPA 72, <br /> 2007 Edition,page 72-33). <br /> Call for design requirements per Authority Having Jurisdiction. Automatic smoke detection is <br /> required. <br /> 15. Install a standby power system in compliance with the requirements of paragraph 604.2.14.1 of the 2009 <br /> International Fire Code. <br /> 16. For buildings with two or more floors, including sub-floors, the alarm system must call point-by-point <br /> reporting to an alarm center. <br /> 17. Carbon monoxide alarms must be installed in all new residential construction in R-1, R-2, and R-3 <br /> occupancies per 2009 International Fire Code,Section 907.2.8.4. <br /> 18. Commercial Cooking Operations -A ventilating hood and duct system with an approved automatic fire- <br /> extinguishing system shall be provided in accordance with the Mechanical Code for commercial-type <br /> food heat-processing equipment that produces grease-laden vapors. <br /> 19. Fire Suppression (Sprinkler) System - An approved automatic suppression system shall be provided as <br /> required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett Municipal Code. The system <br /> must include a mechanical water gong bell. <br /> 13/ <br />