My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
>
Address Records
>
GRAND AVE
>
2900
>
PAGODA VILLAGE
>
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 8:56:50 AM
Creation date
5/30/2019 7:21:35 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
PAGODA VILLAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
515
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2009 Washington • Energy Code Compliance Forms for Nonreside • .nd Multifamily <br /> Building Permit Plans Checklist ENV-CHK <br /> 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February2011 <br /> Project Address Farmers Market Building [Date 5/17/2013 <br /> The following information is necessary to check a building permit application for compliance with the building envelope requirements in the <br /> Washington State Nonresidential Energy Code. <br /> Applicability Code Location Building Department <br /> (yes,no,na) Section Component Information Required on Plans Notes <br /> GENERAL REQUIREMENTS(Sections 1301-1314) <br /> 1301 Scope Unconditioned spaces identified on plans if allowed <br /> N.A. 1310,2 Semi-heated spaces Semi-heated spaces identified on plans if allowed. <br /> N.A. 1310.3 Cold Storage t refrigerate All refrigerated spaces identified on plans, ENV-RFG completed, <br /> 1311 insulation <br /> Yes 1311,1 General installation Indicate installation nethod,densities and clearances to achieve <br /> intended R-value of all insulation materials <br /> Yes 1311,2 Roof/ceiling insul Indicate R-value on roof sections for attics and other roofs; G0.02 <br /> Indicate clearances for attic insulation; <br /> Indicate baffles if eave vents installed; <br /> Indicate face staplingof faced batts <br /> Yes 1311,3 Wall insulation Indicate R-value and framing material on wall sections;Indicate face stapling of faced batts; <br /> Indicate above grade exterior insulation Is protected; <br /> Indicate mass of masonry walls if mass wall claimed <br /> Indicate loose-fill core insulation for masonry walls as necessary <br /> Indicate frequency of grouted cores and bond beams as necessary <br /> Yes 1311.4 Floor insulation Indicate R-value on floor sections; B0.02 <br /> Indicate substantial contact with surface; <br /> Indicate supports not more than 24"oc.; <br /> .Indicate that insulation does not_block airflow through foundation vents. <br /> Yes 1311,5 Slab-on-grade floor Indicate R-value on wall section or foundation detail; 'GO..02 <br /> Indicate slab insulation extends down vertically 24"from top; <br /> Indicate above grade exterior insulation,is protected <br /> N.A. "1311,6 Radiant floor- Indicate R-value on wall section or foundation detail; <br /> Indicate slab insulation extends down vertically 36"from the top; <br /> Indicate above grade exterior insulation is protected; <br /> ` Indicate insulation also under entire slab where req'd,by Official <br /> Yes 1312 Glazing and doom Provide calculation of vertical and overhead glazing area as percent of gross wail area G0.02 <br /> Yea 1312,1 U-factors Indicate glazing and door U-factors on glazing and door <br /> schedule(provide area-weighted calculations as necessary); 00,,02. <br /> Indicate if values are NFRC or default,if default then specify <br /> frame type,glazing layers,gapwidth,low-e coatings,gas filling <br /> Yes 1312,2 SHGC&SC -Indicate glazing solar heat gain coefficient or shading coefficient on glazing - 00,.02`. <br /> schedule(provide area-weighted calculations by orientation as necessary) <br /> 1313 Moisture control <br /> Yes 1313.1 Vapor retarders Indicate vapor retarders applied to warm side of insulation <br /> Yes 1313.2 RooNceiling vap,ret, Indicate vapor retarder on roof section;or list exception WP-000 <br /> Indicate yap,retard,with sealed seams for non-wood structure <br /> Yea 1313,3 Wall vapor retarder Indicate vapor retarder on wall section WF-000 <br /> N.A. 1313A Floor vapor retarder Indicate vapor retarder on floor section <br /> Crawl space yap.ret. Indicate required grade ground cover with required overlapping. <br /> 1314 Air leakage <br /> Yes 1314.1 • <br /> Bldg,envel,sealing Indicate sealing,caulking,gasketing,and weatherstripping vm-000 <br /> Glazing/door sealing Specify maximum air leakage rates for fenestration and door products II <br /> 19p-000 <br /> N.A. 1314.3 'ssemb.as ducts indicate sealing,caulking and gasketing - - - -- <br /> N.A. 1314.4 Recessed Lighting Fixtu Indicate IC rating,ASTM E283 cert.,and gasketing or caulking to ceiling <br /> Yes 1314.5 Loading Dock Seal Indicate weatherseal at cargo and loading dock doors A7.01 <br /> Yes 1314.6 Continuous Air Barrier Indicate air barrier sealing on all roof,wall &floor details Cgpoo1 <br /> Indicate leakage testing method. <br /> Provide testing results to building official Max.leakage of 0.40 cfm/ft2 at 0,3 inchw.g. <br /> PRESCRIPTIVE PERFORMANCE Sections 1320-1323) <br /> ENV-SUM Form Completed and attached. <br /> Indicate number of glazing panes and location of emissivity coating or exception taken IIMIMIIIIIIIIIIIIIII <br /> COMPONENT PERFORMANCE(Sections 1330-1338) <br /> Yea ENV-SUM,ENV-UA, Completed and attached. <br /> &ENV-SHGC Forms <br /> If"no"is shown for any question,provide explanation: <br />
The URL can be used to link to this page
Your browser does not support the video tag.