My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
>
Address Records
>
GRAND AVE
>
2900
>
PAGODA VILLAGE
>
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 8:56:50 AM
Creation date
5/30/2019 7:21:35 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
PAGODA VILLAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
515
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 0099 Washington.State . -•.y Cede COMPliente Forms for Nonresidential a Itifarnil Residential <br /> Mechanical Permit Plans Checklist MECH-CHK <br /> 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 <br /> Project Address Farmers Market Building Date may 17-2013 <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the <br /> Washington State Nonresidential Energy Code, <br /> Applicability Code Location Building Department <br /> (yes,no,na) Section Component Information Required :]on Plans Notes <br /> HVAC REQUIREMENTS(Sections 1401-1424) <br /> 1411 Equipment Performance <br /> Yes 1411.1 MInimum efficiency Equipment schedule with type,capacity,efficiency tom.is <br /> 1.1.X. 1411.1 Combustion hig. Indicate intermittent ignition,flue/draft damper&jacket loss <br /> N.A.. 1411.1 Air-cooled chiller Provide total air and water chiller capacity <br /> ?t.A= 1411.2.1 Water-cooled chiller Full-load and NPLV values adjusted for any non-standard conditions <br /> Yes 1411.4 'Pkg.elec.htg.&"clg= List heat pumps on schedule M .0 <br /> N.A. 1411,5 Unenclosed Heat indicate radiant heat system and occupancy controls <br /> 1412 HVAC Controls <br /> Yes 1412,1 Temperature zones indicate locations on plans <br /> Yes 1412.2 Deadband control indicate 5 degree deadband minimum M..O <br /> N.A. 14123 Humidity control indicate humidistat <br /> Yes 1412.4 Setback and Shutoff indicate thermostat with 7 day program capability&required setback rr ti <br /> Yes 1412.4,1 Dampers Indicate damper location,leakage rate,control type,&max.leakage 141.°' <br /> N.A. 1412.4.2:.Optimum Start indicate optimum start controls <br /> Yes 1412,5 Heat pump control Indicate heat pump thermostant&outdoor lockout on schedule <br /> 1412.6: Combustion heating Indicate modulating_or staged control <br /> Yes j 14121 Balancing Indicate balancing features on plans st4•0 <br /> N.A. 1412.8 Ventilation Ctintrci Indicate demand control ventilation for high-occupancy areas <br /> Yes 1412.9 Loading k& indicate enclosed loading dock&parking garage ventilation system -M2-143 <br /> Garage Ventilation activatiotl.and control method. <br /> Yea 4422 Thermostat interlock Indicate thermostat on plans Ma•p <br /> Yes 14322.1 Temperature Reset Indurate temperature reset method <br /> 1413 Air/Water Economizers <br /> N.A. 1412.1 Single zone systems indicate multiple cooling stage control capability. <br /> Yes 1413.1 Air Econo Operation Indicate 100%capability on schedule Hi.0 <br /> N.A. 1413,1 Wtr Econo Operation Indicate 100%capacity at 45 degF db&40 deg F wb <br /> N..A. <br /> 14132 Wtr Econo Document Indicate max.OSA condition for design clg load&equipment <br /> performance data., <br /> Yes 1413.3 integrated operationIndicate capability for partial doling m3. <br /> 1443,4 Humidification Indicate direct evap or fog atomization w/air economizer <br /> '1414 Ducting Systems <br /> Yes 1414.1 Duct sealing Indicate duct design pressures,sealing,and testing requirements 1141-° <br /> Yes 1414.1.2,Low press.duct test Indicate applicable low pressure duct systems shall be leak tested M1.0 <br /> 4 <br /> W.A. 1414.1.3 High press.dtrcttest',Indicate high pressure duct systems shall be leak tested,and identify <br /> the location of this ductwork on plans <br /> Yes, 1414,2: Duct'insulation Indicate R-value of insulation on duct.. 185,0 <br /> 1415 Piping Systems <br /> M.A. 1415.1 Piping insulation JIndicate R-value of insulation on piping <br /> 1416 Completion Requirements <br /> Yes 1416.3.2 System Balancing Indicate air and water system balancing requirements 7141.0 <br /> Yea 1416=3.3 Functional Testing Provide sequence of operations and test procedures. <br /> Yes 1416.14 Documentation Indicate O&M manuals,record drawings,staff training rsi•o <br /> Yes 1416.3.5 Comm.:Report Indicate requirements for final commissioning report Mi_O <br /> Yea 1416.4 Compliance Chldist Submit to building official upon substantial completion. Mt....0 <br /> Yes Mechanical Summary Forret Completed and attached. Equipment schedule with types,input/output, <br /> ,effiCieney,cfine hpt economizer <br /> 0[5) <br />
The URL can be used to link to this page
Your browser does not support the video tag.