• 0099 Washington.State . -•.y Cede COMPliente Forms for Nonresidential a Itifarnil Residential <br /> Mechanical Permit Plans Checklist MECH-CHK <br /> 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 <br /> Project Address Farmers Market Building Date may 17-2013 <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the <br /> Washington State Nonresidential Energy Code, <br /> Applicability Code Location Building Department <br /> (yes,no,na) Section Component Information Required :]on Plans Notes <br /> HVAC REQUIREMENTS(Sections 1401-1424) <br /> 1411 Equipment Performance <br /> Yes 1411.1 MInimum efficiency Equipment schedule with type,capacity,efficiency tom.is <br /> 1.1.X. 1411.1 Combustion hig. Indicate intermittent ignition,flue/draft damper&jacket loss <br /> N.A.. 1411.1 Air-cooled chiller Provide total air and water chiller capacity <br /> ?t.A= 1411.2.1 Water-cooled chiller Full-load and NPLV values adjusted for any non-standard conditions <br /> Yes 1411.4 'Pkg.elec.htg.&"clg= List heat pumps on schedule M .0 <br /> N.A. 1411,5 Unenclosed Heat indicate radiant heat system and occupancy controls <br /> 1412 HVAC Controls <br /> Yes 1412,1 Temperature zones indicate locations on plans <br /> Yes 1412.2 Deadband control indicate 5 degree deadband minimum M..O <br /> N.A. 14123 Humidity control indicate humidistat <br /> Yes 1412.4 Setback and Shutoff indicate thermostat with 7 day program capability&required setback rr ti <br /> Yes 1412.4,1 Dampers Indicate damper location,leakage rate,control type,&max.leakage 141.°' <br /> N.A. 1412.4.2:.Optimum Start indicate optimum start controls <br /> Yes 1412,5 Heat pump control Indicate heat pump thermostant&outdoor lockout on schedule <br /> 1412.6: Combustion heating Indicate modulating_or staged control <br /> Yes j 14121 Balancing Indicate balancing features on plans st4•0 <br /> N.A. 1412.8 Ventilation Ctintrci Indicate demand control ventilation for high-occupancy areas <br /> Yes 1412.9 Loading k& indicate enclosed loading dock&parking garage ventilation system -M2-143 <br /> Garage Ventilation activatiotl.and control method. <br /> Yea 4422 Thermostat interlock Indicate thermostat on plans Ma•p <br /> Yes 14322.1 Temperature Reset Indurate temperature reset method <br /> 1413 Air/Water Economizers <br /> N.A. 1412.1 Single zone systems indicate multiple cooling stage control capability. <br /> Yes 1413.1 Air Econo Operation Indicate 100%capability on schedule Hi.0 <br /> N.A. 1413,1 Wtr Econo Operation Indicate 100%capacity at 45 degF db&40 deg F wb <br /> N..A. <br /> 14132 Wtr Econo Document Indicate max.OSA condition for design clg load&equipment <br /> performance data., <br /> Yes 1413.3 integrated operationIndicate capability for partial doling m3. <br /> 1443,4 Humidification Indicate direct evap or fog atomization w/air economizer <br /> '1414 Ducting Systems <br /> Yes 1414.1 Duct sealing Indicate duct design pressures,sealing,and testing requirements 1141-° <br /> Yes 1414.1.2,Low press.duct test Indicate applicable low pressure duct systems shall be leak tested M1.0 <br /> 4 <br /> W.A. 1414.1.3 High press.dtrcttest',Indicate high pressure duct systems shall be leak tested,and identify <br /> the location of this ductwork on plans <br /> Yes, 1414,2: Duct'insulation Indicate R-value of insulation on duct.. 185,0 <br /> 1415 Piping Systems <br /> M.A. 1415.1 Piping insulation JIndicate R-value of insulation on piping <br /> 1416 Completion Requirements <br /> Yes 1416.3.2 System Balancing Indicate air and water system balancing requirements 7141.0 <br /> Yea 1416=3.3 Functional Testing Provide sequence of operations and test procedures. <br /> Yes 1416.14 Documentation Indicate O&M manuals,record drawings,staff training rsi•o <br /> Yes 1416.3.5 Comm.:Report Indicate requirements for final commissioning report Mi_O <br /> Yea 1416.4 Compliance Chldist Submit to building official upon substantial completion. Mt....0 <br /> Yes Mechanical Summary Forret Completed and attached. Equipment schedule with types,input/output, <br /> ,effiCieney,cfine hpt economizer <br /> 0[5) <br />