My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
>
Address Records
>
GRAND AVE
>
2900
>
PAGODA VILLAGE
>
2900 GRAND AVE PAGODA VILLAGE 2025-07-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2025 8:56:50 AM
Creation date
5/30/2019 7:21:35 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
2900
Tenant Name
PAGODA VILLAGE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
515
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
studio 1 9 architects <br /> www.studial 9architects.com <br /> 705 2^0 AVE..Ste 505, Seattle,WA 98104 <br /> I'206 466.1225 f 206.299 9107 <br /> 1. Since the envelope compliance information is in the mechanical drawings, the mechanical <br /> drawings should be included. <br /> Response: <br /> Envelope compliance information is provided in the architectural notes. Please see sheet <br /> G0.02 for residential and non-residential envelope compliance notes. <br /> 2. The proposed party wall detail 10/A9.04 indicates discontinuous floor sheathing. Please <br /> provide verification from the engineer that this will be acceptable. If so, fire blocking should be <br /> added. <br /> Response: <br /> Detail 10/A9.40 has been revised and is approved by the structural engineer. Please see <br /> revised detail 10 on A9.40, 55.02 and detail Q on sheet S5.05. In addition please see the <br /> attached additional calculations and narrative regarding the firewall design. <br /> aic3. The typical wall details of A9.04, including the fire wall, should include structural sheathing <br /> where applicable. <br /> Response: <br /> Typical wall details have been revised to show structural sheathing where applicable. Please <br /> see sheet A9.04. <br /> 4. A family or assisted use toilet room is required in accordance with IBC1109.2.1. It appears <br /> unclear if this is intended (sheet A8.41?) <br /> Response: <br /> The toilet room on sheet A8.41 was not intended to satisfy this requirement. A new toilet <br /> room (room # 022) has been added between the two multi-stall restrooms on the ground floor. <br /> See sheets A2.05 &t A2.06 for location and A8.42 for enlarged plan and interior elevations. <br /> ( Pa <br /> ge ( 2/ <br />
The URL can be used to link to this page
Your browser does not support the video tag.