Laserfiche WebLink
Mr. Bill Messner ES-6132 <br /> October 5, 2018 Page 4 <br /> A factor of safety of 1.5 has been applied to the passive resistance value listed above. An earth <br /> pressure distribution for the active earth pressure condition is provided on Plate 3 (Earth Pressure <br /> Detail). Allowable soldier pile deflections for walls subjected to active earth pressures should be <br /> limited to one inch. <br /> Soldier Piles <br /> Soldier pile installation should be observed by a representative of ESNW to verify pile depths and <br /> soil conditions. Appropriate pile lengths and embedment depths shall be determined by the <br /> project structural engineer. If sloughing of the soldier pile excavation occurs, the contractor <br /> should be prepared to case soldier pile excavations as necessary. Where groundwater seepage <br /> is encountered in excavations, localized sloughing should be expected. As indicated in the <br /> following Tieback Anchors section of this letter, soldier piles embedded at least 10 feet into dense <br /> native soils may be designed with an end bearing capacity of 10,000 psf. <br /> Timber Lagging <br /> Lagging should be installed in four-foot maximum lifts as the excavation is advanced. A <br /> representative of ESNW should observe the shoring excavation to assess the stability of the cut. <br /> The lagging should be backfilled as the excavation is advanced to minimize voids between the <br /> lagging and cut face and to reduce the potential for ground subsidence behind the shoring wall. <br /> Where sloughing of the excavation results in the development of a void behind the lagging, <br /> injection of lean-mix concrete into the voided area should be considered. <br /> If the shoring wall is designed as a temporary system, a 50-percent reduction in lateral earth <br /> pressure may be assumed. Permanent lagging may be designed with a 25-percent reduction in <br /> lateral earth pressure. <br /> Tieback Anchors <br /> Where necessary, tiebacks should be located as high on the wall as possible and should be <br /> designed based on the following preliminary parameters: <br /> • Allowable anchor pullout 1,500 psf(dense native soil) <br /> • Declination angle (from horizontal) 15 to 20 degrees <br /> • Embedment (minimum) 10 feet <br /> • Soldier pile end bearing capacity 10,000 psf (dense native soil) <br /> • No load zone See Plate 4 <br /> Earth Solutions NW,LLC <br />