SPECIFICATIONS (CONT.) <br /> a <br /> FIGURE 3.ALLOWABLE SHEAR(POUNDS PER FOOT)FOR PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS-FIR,LARCH,OR SOUTHERN <br /> PINE'''OR WIND OR SEISMIC LOADING ih.r.g"h."(See also 2006 IBC Table 2306.4.1) <br /> Panels Applied Over <br /> Panels Applied Direct to Framing 1/2"or 5/8"Gypsum Sheathing <br /> Panel Performance Minimum <br /> Grade Category** Nail Nail Size Nail Spacing Nail Size Nail Spacing <br /> Penetration (Common or at Panel Edge(in.) (common or at Panel Edges(in.) <br /> in Framing Galvanized Box) Galvanized <br /> (in.) 6 4 3 2(4 Box) 6 4 3 2c44 <br /> 7/16 1-3/8 8d 255 395 505 670`) <br /> Stlad 280 430 5S0(o 730 <br /> Grades <br /> alt 15/32 280 430 550 730 <br /> Grade <br /> 15/32 1-1/2 10d 340 510 6650 870 — — — — <br /> 7/16 58501-3/8 8d 240 350 450 585 10d 260 380 490(4 640 <br /> Rated 15/32 260 380 490 640 <br /> Sheathing 15/32 310 460 600(4 770 — — — — <br /> 1-1/2 lad <br /> 5/8 340 510 665(4 870 — — — — <br /> (a) For framing of other species:(1)Find specific gravity for species of lumber in the AF&PA National Design Specification.(2)For common or galvanized box nails, <br /> find shear value from table above for nail size for actual grade.(3)Multiply value by the following adjustment factor:Specific Gravity Adjustment Factor=[1-(0.5 <br /> -SG)),where SG=specific gravity of the framing.This adjustment shall not be greater than 1. <br /> (b) All panel edges backed with 2-in.nominal or wider framing.Install panels either horizontally or vertically.Space nails maximum 6 in.o.c.along intermediate <br /> framing members for 3/8 Category and 7/16 Category panels installed on studs spaced 24 in.o.c.For other conditions and panel thicknesses,space nails maxi- <br /> mum 12 in.o.c.on intermediate supports. Fasteners shall be located 3/8 in.from panel edges. <br /> (c) Allowable shear values are permitted to be increased to values shown for 15/32 category sheathing with same nailing provided(1)studs are spaced a maximum of <br /> 16 in.o.c.,or(2)panels are applied with long dimension across studs. <br /> (d) Framing at adjoining panel edges shall be 3-in.nominal or wider,and nails shall be staggered where nails are spaced 2 in.o.c.Check local code for variations of <br /> these requirements, <br /> (e) Framing at adjoining panel edges shall be 3-in.nominal or wider,and nails shall be staggered where 10d nails(3 in.x 0.148 in.)having penetration into framing of <br /> more than 1-1/2 in.are spaced 3 inches o.c.Check local code for variations of these requirements. <br /> (f) Where panels are applied on both faces of a wall and nail spacing is less than 6 in.o.c.on either side,panel joints should be offset to fall on different framing <br /> members. Or framing shall be 3 in.nominal or thicker and nails on each side should be staggered. <br /> (g) In Seismic Design Category D,E,or F,where shear design values exceed 350 pounds per lineal foot,all framing members receiving edge nailing from abutting <br /> panel edges shall not be less than a single 3-in.nominal member,or two 2-in.nominal members fastened together in accordance with 2006 IBC Section 2306.1 to <br /> transfer the design shear value between framing members.Wood structural panel joint and sill plate nailing shall be staggered in all cases.See 2006 IBC Section <br /> 2305.311 for sill plate size and anchorage requirements. <br /> (h) Galvanized nails should be hot dipped or tumbled. <br /> (i) For shear loads of normal or permanent load duration as defined by the AF&PA NOS,the values in the table above should be multiplied by 0.63 or 0.56 <br /> respectively. <br /> **Performance Category replaces the fractional nominal thickness used in P52. <br /> Typical Layauf for Shear Walls <br /> Load Fronir�g Blocking Framing <br /> 4,"1",,,',',1'''''..!:A,,,,,,,,:: ': ,':,z,,,:'',,N , <br /> F <br /> Shear wall boundojy Foundation resistance <br /> \ / <br />