My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 HIGHWAY PL WHOLE SITE 2019-06-04
>
Address Records
>
HIGHWAY PL
>
5901
>
WHOLE SITE
>
5901 HIGHWAY PL WHOLE SITE 2019-06-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 1:27:29 PM
Creation date
6/4/2019 1:27:07 PM
Metadata
Fields
Template:
Address Document
Street Name
HIGHWAY PL
Street Number
5901
Tenant Name
WHOLE SITE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
174
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIFICATIONS (CONT.) <br /> a <br /> FIGURE 3.ALLOWABLE SHEAR(POUNDS PER FOOT)FOR PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS-FIR,LARCH,OR SOUTHERN <br /> PINE'''OR WIND OR SEISMIC LOADING ih.r.g"h."(See also 2006 IBC Table 2306.4.1) <br /> Panels Applied Over <br /> Panels Applied Direct to Framing 1/2"or 5/8"Gypsum Sheathing <br /> Panel Performance Minimum <br /> Grade Category** Nail Nail Size Nail Spacing Nail Size Nail Spacing <br /> Penetration (Common or at Panel Edge(in.) (common or at Panel Edges(in.) <br /> in Framing Galvanized Box) Galvanized <br /> (in.) 6 4 3 2(4 Box) 6 4 3 2c44 <br /> 7/16 1-3/8 8d 255 395 505 670`) <br /> Stlad 280 430 5S0(o 730 <br /> Grades <br /> alt 15/32 280 430 550 730 <br /> Grade <br /> 15/32 1-1/2 10d 340 510 6650 870 — — — — <br /> 7/16 58501-3/8 8d 240 350 450 585 10d 260 380 490(4 640 <br /> Rated 15/32 260 380 490 640 <br /> Sheathing 15/32 310 460 600(4 770 — — — — <br /> 1-1/2 lad <br /> 5/8 340 510 665(4 870 — — — — <br /> (a) For framing of other species:(1)Find specific gravity for species of lumber in the AF&PA National Design Specification.(2)For common or galvanized box nails, <br /> find shear value from table above for nail size for actual grade.(3)Multiply value by the following adjustment factor:Specific Gravity Adjustment Factor=[1-(0.5 <br /> -SG)),where SG=specific gravity of the framing.This adjustment shall not be greater than 1. <br /> (b) All panel edges backed with 2-in.nominal or wider framing.Install panels either horizontally or vertically.Space nails maximum 6 in.o.c.along intermediate <br /> framing members for 3/8 Category and 7/16 Category panels installed on studs spaced 24 in.o.c.For other conditions and panel thicknesses,space nails maxi- <br /> mum 12 in.o.c.on intermediate supports. Fasteners shall be located 3/8 in.from panel edges. <br /> (c) Allowable shear values are permitted to be increased to values shown for 15/32 category sheathing with same nailing provided(1)studs are spaced a maximum of <br /> 16 in.o.c.,or(2)panels are applied with long dimension across studs. <br /> (d) Framing at adjoining panel edges shall be 3-in.nominal or wider,and nails shall be staggered where nails are spaced 2 in.o.c.Check local code for variations of <br /> these requirements, <br /> (e) Framing at adjoining panel edges shall be 3-in.nominal or wider,and nails shall be staggered where 10d nails(3 in.x 0.148 in.)having penetration into framing of <br /> more than 1-1/2 in.are spaced 3 inches o.c.Check local code for variations of these requirements. <br /> (f) Where panels are applied on both faces of a wall and nail spacing is less than 6 in.o.c.on either side,panel joints should be offset to fall on different framing <br /> members. Or framing shall be 3 in.nominal or thicker and nails on each side should be staggered. <br /> (g) In Seismic Design Category D,E,or F,where shear design values exceed 350 pounds per lineal foot,all framing members receiving edge nailing from abutting <br /> panel edges shall not be less than a single 3-in.nominal member,or two 2-in.nominal members fastened together in accordance with 2006 IBC Section 2306.1 to <br /> transfer the design shear value between framing members.Wood structural panel joint and sill plate nailing shall be staggered in all cases.See 2006 IBC Section <br /> 2305.311 for sill plate size and anchorage requirements. <br /> (h) Galvanized nails should be hot dipped or tumbled. <br /> (i) For shear loads of normal or permanent load duration as defined by the AF&PA NOS,the values in the table above should be multiplied by 0.63 or 0.56 <br /> respectively. <br /> **Performance Category replaces the fractional nominal thickness used in P52. <br /> Typical Layauf for Shear Walls <br /> Load Fronir�g Blocking Framing <br /> 4,"1",,,',',1'''''..!:A,,,,,,,,:: ': ,':,z,,,:'',,N , <br /> F <br /> Shear wall boundojy Foundation resistance <br /> \ / <br />
The URL can be used to link to this page
Your browser does not support the video tag.