Laserfiche WebLink
832,5 8 arab Bars ineBathroo.ms N/A C ' YES NO <br /> Grab bars shall be installed for all water closets(toilets),bathtubs and showers according to R325.8. 0' 0 <br /> Water Closets(toilet)shall have grab bars installed on both sides according to R325.8—R325.8.3.2. 0 <br /> Bathtubs shall have two vertical and three horizontal grab bars installed according to R325.8—R325.8.2&R325.8.4—R325.8.4.2LW 0 <br /> Shower stalls have two vertical and horizontal grab bars mounted on all sides of shower according to R325.8—R325.8.2& 0/ 0 <br /> R325.8.5—R325.8.5.2. <br /> Shower stalls must be minimum size of 30 inches deep by 48 inches long .-_. 0" 0 <br /> gG1Q3= s C1O $wi t g ? 1, p x Wit[ _ ..r.. YES' NO <br /> AF105.2 Must be surrounded by a barrier that is 48 inches high,may hav- ...,s and or gates that must have audible alarms when o o <br /> opened. <br /> AG105 5 EXCEPTION:Po Spas or Hot Tubs with a safety cover which complies with ASTM F 1346 0 0 <br /> ASSED QCORRECTIONS REQUIRED Cl PERMIT REQUIRED <br /> INSPE R'SNAMEr(PRINT) :o <br /> jl ECTOR'S SIGNATU DATE:= <br /> INSPECTOR'SOFFICE`ADDRESS;. PHONE NUMBER <br /> Application.andinspection checklist devetaped by Washington Association of Building Officials(WI BO),in'coop"eration with'Department of Social and <br /> Heulth Ses1+'ac s MKS)forruse.by,both depart rie is and licensers, ., 0 /O1/2013 <br /> Effective: 2013 July 01 <br /> Updated: 2013 May <br />