WAC 296-46B-900: ELECTRICAL PLAN REVIEW <br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required.Then select the box next to(a)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br /> required, select the box next to(b)and (c)to acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> *If item(a)-(ii, iii,or v) is selected,the work must also comply with section(a)-(vii).See arrow flow chart below. <br /> (3)Electrical plan review. <br /> 0 (a) Electrical plan review is not required for: <br /> ❑ (i)Low voltage systems; <br /> 4--1=I (ii)Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ❑ (iii)Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution system <br /> o does not include: <br /> (A)Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2;or <br /> (C)A required fire pump system. <br /> ❑ (v)Modifications to existing electrical installations where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B)Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (C)Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br /> and <br /> (D)Service or feeder load calculations are increased by 5%or less. <br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell, or wind electric system(s)with a total <br /> ❑ rating of 9600 watts or less. <br /> (vii)For installations in (a)(ii), (iii),and (v)of this subsection to be considered,the following must be available <br /> ❑ to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed;and <br /> (D)Provide information showing that the service and feeder(s)supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical, dental, and chiropractic clinic"of which is a clinic or <br /> ❑ physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> ® (b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional,or health care <br /> occupancies defined in this chapter. <br /> 0 (c) If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Table 40134 Table S00=2 <br /> Health or Personal Care Facilities Educational anti institutional.Facilities.Places of Assembly.or Other f:acihtivs <br /> Health Or Ptl1'SdrInt Carr Facility Plan Review <br /> t ,3 Re uirec! Educational, institutional.or Plan,Rev,ew <br /> y'__.. q <br /> veG other Facday Types Reg4fred <br /> !mit .Innngn-r Yes =et_ata al res <br /> r�.a trr+;t S:Rt/t°;c rt <br /> r etaf41Pr!','mr._..._ Yes <br /> Yes <br /> btate alrehr,lt;re h,+spltat Yes Notes to Tables 9ran-9 and 906.2. <br /> p,ivatce-yclear4 .A.city'al -,or._ed.c.:t;_e-mca .-..F _=•cr-. _. <br /> 1 ,,tern%trr kn,+ti..: Yes Y"aj reto,re p.a..rci E`JJ:.r'oC !xF tjc r t <br /> f111A6ttr y 3WY t:•sy fJc411ty Yes ret''awed by tae oe e'tn-e^t. <br /> €c.-^rtath.�nrrtrlla+y:'isLiwi. Yes - <br /> u I i ni+�t t o to nt facRiry Yes �}� VII' <br /> //) <br /> • ttG,rt xeiVlC�ic'[Ilty Yes I/ D I — 1021 <br /> 2_ 1 <br /> „Jolt+ t+t'+tl 1 ,hf4ltatlo Yes PERMIT# V// r/ Page 2-Plan Review <br />