INSTALLATION <br /> The damper clamp with hex bolt (Fig. 11-1) is provided as a means to �` <br /> prevent full closure of the damper blade.The clamp is easily attached to <br /> most damper blades with pliers or a wrench, and must be permanently <br /> installed.The clamp is designed to prevent accidental closure of the damper C <br /> when installed as illustrated(Fig.11-2 and Fig.11-3).Should the clamp not <br /> fit, or fail to provide the permanent vent opening listed in the table found <br /> above,have a permanent stop installed,remove the <br /> damper blade, or have the damper cut to provide Seik <br /> t screw = Wm <br /> + <br /> the minimum permanent opening required. \ 41KiN\ mu NM <br /> Note: These are minimum damper opening *2 MIN c <br /> 11 MEI <br /> specifications. The damper must beDam er clam <br /> completely opened when operating this g pMINI MMIll <br /> Open Closed <br /> Fig.11-1 Fig.11-2 ,7ccsSFig.11-3 <br /> gas appliance to achieve the best ventilation <br /> possible. <br /> INSTALLING THE BURNER <br /> The Real-Fyre gas log set must be installed by a qualified professional service technician. Instructions <br /> must be followed carefully to ensure proper performance and full benefit from the gas log set.Check to be <br /> sure the log set is designed and labeled for the type of gas(natural or propane gas)supplied to the <br /> fireplace. Fireplace floor must be level,clean, and smooth. <br /> WARNING: Faureto position the parts in accordance with these diagrams or failure to use onlyparts, <br /> specifically approved with this appliance may result in property damage or personal injury. <br /> REFER TO THE PARTS LIST WHEN FOLLOWING THESE INSTRUCTIONS. <br /> 1. MAKE SURE THE FIREPLACE GAS SUPPLY IS TURNED OFF. <br /> 2. Locate the gas-supply stub inside the fireplace and remove the cap, if attached (see Fig. 11-4 <br /> CAUTION: When removing the cap,make sure the stub does not turn,loosening the connection jnside t wall. <br /> 3. Attach the nut end of the flex connector to the adapter found on the valve or,if attached,on the reg at- <br /> behind the valve.Tighten securely. 0 <br /> 4. Place the burner system into the fireplace so the open burner pan faces outward. 43, <br /> 5. Locate the grate and attach the log locators to the 2 outer bars of the grate with screws and ni. <br /> log locators should be loosely positioned toward the middle of the bars with screw slots facing towards <br /> fireplace side walls (Fig. 11-5).Temporarily place the front log at the front of the grate, to correctly <br /> determine the log locator position. Slide the log locators up against the rear of the front log.Tighten <br /> the log locators in place. Remove the front log. <br /> 6. Place the grate over the burner pan so the log locator brackets fit over the back edge of the burner pan <br /> to lock it in position. <br /> 7. Center this assembly in the fireplace and place it as far back in the fireplace as possible.Remove the <br /> grate for the gas connection and granule/ember placement. <br /> 1 <br /> ) Fig. 11-5 Log locators on grate <br /> -0 , <br /> 77 <br /> Gas line <br /> cap _ <br /> i;� (Brackets are to fit over <br /> Gas supply _J ' back edge of burner pan) <br /> line slob <br />