Laserfiche WebLink
ENERVEX® I1 <br /> GREEN BEFORE GREEN WAS IN <br /> September 28,2016 <br /> Kevin McBride <br /> Anderson Fireplace and Spas <br /> RE: Cogdill residence <br /> Dear Kevin, <br /> Please be advised that based on the size of the opening of the gas fireplace (36" x 28"), the selection is an RS09 <br /> chimney fan using a 10"x10" ID clay tile chimney with 15' of height. The corresponding combustion air requirement <br /> for this fireplace is 222 cfm. The selection has been designed under the ENERVEX standards. The calculations <br /> were done in accordance with both ASHRAE guidelines and NFPA 211 Standard for Chimneys, Fireplaces, Vents, <br /> and Solid Fuel Burning appliances, in which we take the opening of the fireplace and generate a volumetric flow. <br /> The system as designed comes with ENERVEX's full product warranty. <br /> The ENERVEX ADC100 Universal Fan Control is appropriate for use with electronic ignitions such as those found in <br /> the RH Peterson gas log sets. <br /> Please contact me should you have any further questions. <br /> Sincerely, <br /> Karl R. Coleman <br /> Engineering Manager <br /> ENERVEX, Inc <br /> 800-255-2923 x 2514 <br /> ENERVEX INC. P:770.587.3238 info@enervex.com <br /> 1200 Northmeadow Pkwy.,Suite 180 F:770.587.4731 www.enervex.com <br /> Roswell,GA 30076 T:800.255.2923 <br /> USA <br />