My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9900 19TH AVE SE WINCO FOODS 2018-01-02 MF Import
>
Address Records
>
19TH AVE SE
>
9900
>
WINCO FOODS
>
9900 19TH AVE SE WINCO FOODS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/14/2021 11:32:58 AM
Creation date
6/6/2019 11:28:59 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9900
Tenant Name
WINCO FOODS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
400
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A copy of NFPA 72 Record of Completion form m, ist be filled out prior to final occupancy <br />(NFPA 72, 2007 Edition, page 72-33). <br />Call for design requirements per Authority Having Jurisdiction. <br />Automatic smoke detection is required. <br />A new addressable panel will need to be installed. <br />9. Commercial Cooking Operations - A ventilating hood and duct system with an approved <br />automatic fire -extinguishing system shall be provided in accordance with the Mechanical <br />Code for commercial -type food heat-Prucessing equipment that produces grease -laden <br />vapors. <br />10. Fire Suppression (Sprinkler) System -An approved automatic suppression system shall be <br />provided as required by City Ordinance No. 3021-07, Chapter 16.76, of the Everett <br />Municipal Code. The system must include a mechanical water gong bell. <br />Plans for any such system shall be submitted to the Engineering & Public Services <br />Department for examination and approval. Such plans shall include plans for the <br />underground mains that will supply the sprinkler system. <br />The 'type of sprinkler to be installed will be determined by the Building Official. It may be an <br />NFPA 13. NFPA 13R, or NFPA 13D system depending upon several factors. Sprinkler <br />installation shall not begin without an approved and stamped set of plans from the <br />Engineering & Public Services Department. The Fire Department will also review the <br />plans and shall field inspect the installation based only on approved plans that must be on <br />site. Changes to plans must be approved by both the Engineering & P- -blic Services and <br />Fire Departments. <br />Aboveground sprinkler piping shall be hydrostatically tested as established in NFPA <br />Standard 13. Underground piping shall be hydrostatically tested and flushed as <br />established in NFPA Standard 24 for private fire mains. (Below -ground piping must be <br />installed by Washington State Patrol Licensed Underground Sprinkler line certified <br />"U" installers. For further information, contact the State Fire Marshal's Office at <br />(360) 570-3134 or contact the Everett Fire Department at (425) 257-8124.) All such <br />tests shall be witnessed by a Fire Department Inspector. Call (425) 257-8126 to make an <br />appointment for inspection. <br />Contractors' materials and test certificates shall be submitted to the Everett Fire <br />Department prior to issuance of any Certificates of Occupancy. <br />Call (425) 257-8'124 for more information. <br />Sprinkler system (NFPA 13) will reflect change in occupancy <br />11. The Snohomish County Emergency Radio System is employed by the City of Everett Fire <br />Department emergency crews and operates at 800 MHz. Large metal -framed or metal and <br />concrete buildings can weaken the signal so that communication and, therefore, firefighter <br />safety is compromised. This structure must meet the requirements of EMC 16.03,060. <br />Section 511, which specifically addresses required radio system performance standards in <br />