My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2132 BROADWAY 2019-06-24
>
Address Records
>
BROADWAY
>
2132
>
2132 BROADWAY 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 11:40:08 AM
Creation date
6/10/2019 3:35:28 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
2132
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting Summary LGT-SUM <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Info Project Title: Broadway Animal Hospital-alteration Date 6/28/2017 <br /> Compliance Applicant information. Provide contact information for individual who can For Building Department Use <br /> forms do not respond to inquiries about compliance form information provided. <br /> require a Company Name: Morgan Robert Elliott,Architect <br /> password to <br /> use. instructional Company Address: 2320 29th Ave S,Seattle WA 98144 <br /> and calculating <br /> cells are write- Applicant Name: Morgan Elliott <br /> protected. <br /> Applicant Phone: 206-354-2412 <br /> Applicant Email: morganrobertelliott@gmail.com <br /> Project Description ❑ New Building 0 Addition EI Alteration 0 Plans Included <br /> Include PROJ-SUM form(included in envelope forms workbook)with lighting compliance forms. <br /> Building Additions Compliance Method Interior lighting Exterior lighting <br /> Lighting systems in addition area comply with all applicable <br /> 0 ❑ <br /> provisions as a stand alone new construction project <br /> Refer to Section C502.2.6 for additional <br /> requirements. Lighting systems in addition are combined with existing <br /> 0 ❑ <br /> building lighting systems to demonstrate compliance <br /> Addition is combined with existing: <br /> For interior lighting projects, include new+existing interior lighting fixture wattage in Proposed lighting <br /> Wattage table in LTG-INT-BW or LTG-INT-SPACE form. <br /> For exterior lighting projects, include new+existing exterior lighting fixture wattage in Proposed <br /> Tradable and Proposed Non-Tradable Lighting Wattage tables in LTG-EXT form. <br /> Interior and Exterior Lighting Power Interior lighting Parking garage Exterior lighting <br /> Lighting Alterations 50%or more of existing are replaced 0 ❑ 0 <br /> Select all Lighting Power and Lighting <br /> Control elements that apply to the scope Less than 50%of existing are replaced 0 El <br /> of the retrofit project, If project includes a <br /> combination of spaces where less than Lamp and/or ballast replacement only — <br /> 0 <br /> 0 <br /> 0 <br /> 50%of the existing fixtures are replaced in existing total wattage not increased <br /> some spaces,and 50%or more of the <br /> fixtures are replaced in others, then 50%or more replaced-Total lighting power of new+existing-to-remain fixtures shall comply with total <br /> provide separate lighting power LPA per Sections C405.4.2 and C405.5.2. Include new+existing-to-remain factures in Proposed <br /> compliance forms for the two retrofit Lighting Wattage table in LTG-iNT-BLD, LTG-INT-SPACE or LTG-EXT form. <br /> conditions. Spaces undergoing the same Less than 50%replaced-Total lighting power of new+existing-to-remain fixtures shall not exceed the <br /> type of retrofit may be combined into one total lighting power prior to alteration. Include new+existing-to-remain fixtures in the Proposed Lighting <br /> lighting power compliance form. Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form. <br /> 50%threshold applies to number of luminaires for interior spaces and parking garages, and total <br /> Refer to Section C5036 for additional installed wattage for exterior luminaires. <br /> requirements. <br /> Lighting Controls Interior lighting Parking garage Exterior lighting <br /> All alteration lighting controls shall be New wiring installed to serve added <br /> commissioned per C408.3 fixtures and/or fixtures relocated to new 0 0 0 <br /> circuit(s) <br /> New or moved lighting panel 0 0 0 <br /> Interior space is reconfigured - <br /> 0 <br /> luminaires unchanged or relocated only <br /> New wiring or circuit-For interior lighting, provide required manual controls per C405.2.3, occupancy <br /> sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application speck lighting <br /> 0 controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7 <br /> No changes are being made to New or moved panel-Provide all applicable lighting controls as noted for New Wiring and automatic <br /> the interior or exterior lighting time switch controls per C405.2.2. <br /> systems and existing space <br /> uses and configuration are not Reconfigured interior space-Provide all required lighting controls that apply to a new interior space. <br /> changed. Application specific lighting control provisions per C405.25 do not apply to reconfigured spaces. <br /> Change of Space Use ❑ Existing interior lighting systems in areas under-going a change in space use are upgraded to <br /> comply with LPAs for the new space types per Tables C405.4.2(1)or C405.4.2(2), <br /> Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in <br /> LTG-INT-BLD or LTG-iNT-SPACE form. <br />
The URL can be used to link to this page
Your browser does not support the video tag.