My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2132 BROADWAY 2019-06-24
>
Address Records
>
BROADWAY
>
2132
>
2132 BROADWAY 2019-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2019 11:40:08 AM
Creation date
6/10/2019 3:35:28 PM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
2132
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Broadway Animal Hospital-alteration Date 6/28/2017 <br /> Calculation a Q Addition- 0 Addition For Building Department Use <br /> Area NOTE a stand alone +existing <br /> 0 Spaces where <50%of Q Spaces where z 50%of 0 <br /> luminaires are replaced luminaires are replaced <br /> LPA O Standard Q Additional Efficiency Package Option Q <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3, the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE' <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type Height NOTE 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Total Area <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Enter Total Existing Lighting Watts(prior to Alteration) 2 0 4 8 <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 204 8 <br /> Proposed Lighting Wattage"°'t <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE 4,e,s Fixtures Fixture NOTE T Proposed <br /> Storage,Mech Surface mount 2-lamp T8 linear fluorescent 4 64 256 <br /> Corridor Surface mount 2-lamp T8 linear fluorescent 4 64 256 <br /> Office Surface mount LED 1 4 8 4 8 <br /> Exam Rooms Surface mount 3-lamp T8 linear fluorescent 8 96 7 68 <br /> Reception Surface mount LED 4 4 8 192 <br /> Waiting area Surface mount LED 1 4 8 • 4 8 <br /> Dental Surface mount 3-lamp T8 linear fluorescent 2 96 192 <br /> Pharmacy Surface mount 3-lamp T8 linear fluorescent 2 9 6 192 <br /> Restroom Surface mount 2-lamp T8 linear fluorescent 1 64 64 <br /> exits LED Exit Signs 2 5 10 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 2026 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405 4.2(2), Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description, indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture, and ballast type(if included). For <br /> track lighting, list the length of the track(in feet)in addition to the fixture, lamp, and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.41, note exception number and leave Wetts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For <br /> luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage). For low voltage <br /> lighting, enter the wattage of the transformer. For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot, or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance. Refer to C502.1. <br /> b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a <br /> building addition will comply as combined with the overall existing building lighting systems,include all applicable existing Space Types <br /> and gross interior areas. <br /> c.If less than 50%of existing lighting fixtures will be replaced, provide total existing lighting wattage(prior to alteration)in the space provided <br /> 4,floc IlAevirnttrN 41Inuia4 I inhfinn IA/offence fehrn <br />
The URL can be used to link to this page
Your browser does not support the video tag.