Laserfiche WebLink
GENERAL NOTES: APPROVED (-1LOT - s PROJECT DATA: DRAWING INDEX: LARSEN ' <br /> ARCHITECT <br /> 1. ALL WORK SAEO,COMPLY ORLiTHE 201REG ATIIONS.INCLUDING <br /> BUILDINGCODE,AND ANY PUBL� W RKS DE ART ENT ,1 n - I „ , AIA <br /> APPLICABLE STATE,COUNTY,WITH <br /> LOCAL REGULATIONS,INCLUDINGDING WASHINGTON �`1X.t. vtA <br /> STATE ENERGY CODE. LEGAL DESCRIPTION: <br /> 2. THE CONTRACTOR IS RESPONSIBLE TO CHECK THE PLANS AND TO NOTIFY THE 9845 NE 27th Street <br /> ARCHITECT OF ANY ERRORS OR OMMISSIONS PRIOR TO START OF CONSTRUCTION. BY LOTS 27 AND 28,BLOCK 448,MINNESOTA ADOLTION TO M.0 GENERAL INFORMATION/SITE PLAN Bellevue,WA 98004 <br /> 3. WRITTEN DIMENSIONS HAVE PRECEDENCE OVER SCALED DIMENSIONS.DO NOT SCALE ( THE CITY OF EVERETT,ACCORDING TO THE PLAT THEREOF, <br /> '(7��}/ RECORDED IN VOLUME 4 OF PLATS,PAGES 48,RECORDS OF, S SITE SURVEY <br /> DRAWINGS.DIMENSIONS ARE TYPICALLY TAKEN TO ROUGH FRAMING. DATE 2,111' 425.442.1350 <br /> SNOHOMISH COUNTY,WASHINGTON <br /> 4.ALL GLAZING WITHIN 18"OF THE FLOOR OR WITHIN 12"OF ANY DOOR IS TO BE CITY OF EVERETT REVIEWED FOR PERMIT / r A2.0 FLOOR PLAN&ELEVATIONS -. <br /> TEMPERED SAFETY GLAZING. 0)311-0Q-032. /n TAX ACCESS°R#00516444802700 A3.0 SECTIONS&DETAILS <br /> IlJ/[! A4.1 STRUCTURAL NOTES&SW SCHEDULE <br /> 5. REMOVE ALL CONSTRUCTION 008015 FROM SITE r ZONING R-2 A4.1 STRUCTURAL PLANS&DETAILS <br /> 6. INSTALL ACCESS HATCHES TO ALL ATTICS GREATER THAN 30"IN HEIGHT. CONSTRUCTION TYPE V(B) <br /> SPRINKLERS-NO <br /> 1 y,." 4niv\,.,b\ed,- . Vf' SITE AREA:0.12 ACRES <br /> ('�� Cht7S,(ta, ( 5,762 SF <br /> \�I f(Tr`(iC:63'� ✓ltYTi & W A 23.5/1 -.---- I IMPERVIOUS AREAS: <br /> CrvT v ` `^— gl `^ .{T v� I /)/ EXISTING-1,749 SF(30.3%) <br /> 7 > �l� PROPOSED-2,163 SF(37.5%) <br /> I 11/10M( <br /> �}���/ ///��� ,//� NET ADD OF 414 SF 7 <br /> -----•--•--------•�----------- I T-- - - �'---�..—•'---#---i- (I 1 "T�� !i r <br /> STRUCTURAL COVERAGE: <br /> �-----—•---- -------•—•-• •--—•—I I I I i j (871+120+348+407)/5,762=30.3% Z <br /> 16' 1 (E)HOUSE---'\�\\\ \\ <br /> 1 I I <br /> I IIH <br /> I ADDITION I ALLEY 1 I I 1 I I I al! (E)FRONT PORCH-\\I\\ <br /> III I I I I I I I (E)GARAGE ,\\ <br /> . - .I— —_--— --t-----LSsa•ar—OVE"- —.. —I.--- I PROPOSED ADDITION---- <br /> 0 <br /> --_--1 <br /> -- I --SIDE --- .-----.-- .00(excl.---�-—.�— I <br /> —1 - - -I -- N I j <br /> REAR 5'SETBACK q _�_ 1 _L_--_ fl 11 I o,G• <br /> 20'SETBACK I -C f,Y4I <br /> II I <br /> 1. u❑ I L—J I I j aI I Q <br /> \ 40' Lil <br /> \l(�\ (E)lIARWGE ,/, f <br /> j jj�ji .i-i., I j I 1 (E)CCNC I I G,I <br /> J I I I j�/j C STIES I I P. <br /> 20' �/ jjj r____ I (E+HOUSE ,HH y Z I Z <br /> ALLEY (E)CONC / j% I I 6' 1 1 r�y-)FRyM, I <br /> PARKING : L 1L__ i I 1 IPI°ACMI 1 = ENERGY CODE SUMMARY: x-11 <br /> LqE", AR00 q ft 12' I II 1 I I 1 INSULATION R-VALUES&ASSEMBLY U-FACTORS PER TABLE 0402.1.1 <br /> 157 RIIPA710 1 I 20' ETBA K I I ROOF(VAULTED SINGLE!01ST SPAL7:) R-38 <br /> I <br /> _ Ir 157 s1ylyB��k <br /> 3" C DRAIN I I FR NT I I E {OE.': I ROOF(ATTIC) R-49 REVISIONS: (� <br /> g I (E)GARAGE AREA 348$q ft PIP I I j j 1 a 6 <br /> LLJ <br /> g ; (E)HOUSE AREA: 871 sIIIIIIFFFFFF ft \4,x4,x JI OPAQUE WALLS(EXTERIOR,ABOVE GRADE) NA' <br /> z f: <br /> I <br /> I (E)PORCH AREA: 120 R I ft --'--4 GRAVE Y I I I I 1 I NEW 206 WALLS R-21 <br /> PROPOSED ADDEITON 407 sq k---_••----•• IDE <br /> 5 SETBACK o a O'EICI WELL 3I I+ 11'+• I REF FLOOR OVER CRAWLSPACE R-30Ce 2r1 <br /> m <br /> '-- 8:' – I+�---- 7�,--- 1 T7+5' I <br /> HEATED <br /> (AT PERIMETER&UNDER R-10 O <br /> Z <br /> +6 --•— —•--- GLAZING(VERTICAL) So=.24 MAX.(SEE BELOW) W W Z <br /> SITE PLAN a V 1W m'I GLAZING(OVERHEAD) Uo=.50 MAX 2 <br /> DOOR(EXTERIOR) Uo=.20 MAX. '4'-'"h <br /> SCALE 1,10' DUCTS R-8 MIN. PROJECT TEAM: / /'� Z <br /> SITE AREA: 5,762 sq k `/ , <br /> HOT WATER PIPES R-4 MN. <br /> OWNER: p <br /> LOIS FISHER N W <br /> ALL EXPOSED INSULATION IS TO HAVE A FLAME SPREAD RATING OF LESS 2110 PINE STREET <br /> THAN 25 AND A SMOKE DENSITY RATING OF LESS THAN 450. EVERETT,WA 98201 <br /> PER 0302.2.OUTDOOR DESIGN CONDITIONS(EVERETT)21•HEATING,AND • <br /> _ 79•COOLING. SITE ADDRESS: <br /> DRAWING LEGEND: PER 6303.1 CONTRACTOR WILL PROVIDE CERTIFICATION OF INSULATION 2110 PINE STREET O I– <br /> z <br /> TYPE,MANUFACTURER AND INSTALLATION. EVERETT,WA 98201 U�+•� Z <br /> NEW 2 04 OR 2x6 WALL CONSTRUCTION AS INDICATED. PER R303.1.1.1 CONTRACTOR WILL PROVIDE ATTIC INSULATION DEPTH LU C LU W. <br /> MARKERS.FOR EVERY 300 SF OF ATTIC ARCHITECT: _ Q <br /> INDICATES EXISTING WALL REMOVED. ci <br /> PER R401.3 CONTRACTOR WILL PROVIDE POSTED CERTIFICATE NEAR LARSEN ARCHITECT w 4' J 3 <br /> ELECTRICAL PANEL LISTING ENERGY FEATURES OF THE STRUCTURE 9845 NE 27TH STREET Q w o <br /> Q BELLEVUE,WA 98004 <br /> DETAIL REFERENCE,DETAIL IDENTIFIER AT TOP AND ? <br /> SHEET LOCATION AT BOTTOM. `•L_ <br /> SVEN LARSEN,PRINCIPAL <br /> VICINITY MAP" 2110 PINE STREET PER 6402.4.1.2 AIR LEAKAGE.TEST NOT REQUIRED FOR ADDITION<500 SF. <br /> Q BULGING SECTION REFERENCE. SEE TABLE 0402.4.1.1 FOR AIR BARRIER&INSULATION INSTALLATION 425.442.1350 <br /> © REQUIREMENTS <br /> SITE AN INTERIOR ELEVATION REFERENCE <br /> STRUCTURAL ENGINEER: <br /> 3/A3.0 HEATING SYSTEM: ELECTRIC BASEBOARD @ MASTER BEDROOM SITE <br /> TI-is ^1 r;;'r a! of,l I y a T:o!i S to ELECTRIC FLOOR MAT HEAT @ MASTER BATH SWENSON SAY FACET <br /> s v, O SD SMOKE DETECTOR,120 V WITH BATTERY BACKUP PER SECTION 8403.1.1 PROVIDE PROGRAMMABLE THERMOSTAT ROOM. 2124 THIRD AVENUE,SUITE 100 PLAN <br /> 21st STREET the i rk L.,--,:no performed unde=r SEATTLE,WA 98121 q_ <br /> PER R406-E.G CREDITS REQUIRED(ADDITIONS<500 SF).PER TABLE 406.2- <br /> Per rr 1 1( h — n 1 d-VERTICAL FENESTRATION Uo=0.24 RYAN REICHMAN,PRINCIPAL PROJECT <br /> . ,x ,Ry�,� DOOR-WITH DOOR IDENTIFICATION BETH BROWN,7,,PROJECT ENGINEER INFO <br /> and does not re:.'�pnize any <br /> ',7; existingsiruci.re that may net 253.284.9471 FAX <br /> S x SILT FENCE(EROSION CONTROL) <br /> a RECEPTACLE.rne,.:t Zoning Code SURVEYOR: PERMIT SET <br /> 120 VOLT DUPLEX c E DELTA LAND SURVEYORS <br /> 120 VOLT ARC-FAULT RECEPTACLE. 370 N.EAST CAMANO DRIVE,STE 5-66 <br /> CAMANO ISLAND,WA 98282 Date:JAN 27,2017 <br /> 22nd STREET ,IW,I, 120 VOLT DUPLEX GFI RECEPTACLE DOUG ROSS,PLS <br /> Revs: <br /> APPROVED <br /> INDICATES <br /> SWITCH(DASHED LEADER LINE <br /> INDICATES 3-WAY SWITCH) 360.939.0316 <br /> In' PLANNING & COMMUNITY D 360.939.2078 FAX <br /> : ,7 N DEVE OPMENT DEPT. - <br /> ELECTRICAL SWITCH WITH DINNER CONTROL <br /> 1.3 t.� � i 3D <br /> :,. -* 3-WAY ELECTRICAL SWITCH WITH DIMMER CONTROL <br /> // FISHER ADDITION <br /> MAR 2 9 2017 1 DATE 0 1 j HOSE BIBB Z <br /> u <br /> EXHAUST FAN+CFM l Al .0 <br /> CITY OF EVERETT <br /> Permit Services <br />