My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9610 19TH AVE SE VERIZON WIRELESS ANTENNA 2019-07-18
>
Address Records
>
19TH AVE SE
>
9610
>
VERIZON WIRELESS ANTENNA
>
9610 19TH AVE SE VERIZON WIRELESS ANTENNA 2019-07-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2019 2:59:03 PM
Creation date
6/11/2019 12:07:39 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9610
Tenant Name
VERIZON WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> NOTES: <br /> GENERAL NOTES: 0 1. INSERT SCISSOR BRACKETS BETWEEN NE RRUS NOTE: <br /> 0 UPPER ANTENNA MOUNTING BRACKET AND THE 1. RRUS MOUNTED NEAR ANTENNAS. <br /> ND <br /> UPPER POLE ADAPTER BRACKET.SECURE USING 2. CONTRACTOR TO VERIFY WITH -M <br /> 1. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, © ° O ;1 1/2 INCH HARDWARE PROVIDED. MANUFACTURER SPEC's FOR <br /> REGULATIONS AND SAFETY REGULATIONS,ALL OSHA REGULATIONS,ALL PUBLIC ^`'a 2. TO SET THE DEGREE OF DOWNTILT,ALIGN THE POLE MOUNTED • <br /> f I MOUNTING DETAILS. kil <br /> bin <br /> AND MUNICIPAL AUTHORITIES,AND ANY UTILITY COMPANIES'REGULATIONS AND 0 • DESIRED HOLES ON THE SCISSOR BRACKETS RRU (� 3. RRUS DETAIL AS SHOWN ASA <br /> DIRECTIVES. , ��. AND SECURE USING 5/16 INCH HARDWARE \ /1 REFERENCE AND IS SUBJECT TO —p <br /> �'1 .,© PROVIDED. 1[ CHANGE. M.i i 11 0 <br /> 2. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE `1�. -��13. THE NUMBER OF CONNECTORS WILL VARY PIPE MOUNT 4. PLATFORM SHOWN AS TYPICAL. • <br /> SCOPE OF WORK.EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. '¢'� - BASED ON ANTENNA TYPE. ADAPTER VERIFY ACTUAL CONDITIONS IN FIELD. <br /> THE CONTRACTOR IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT �• <br /> ANY AND ALL P. , NOTE TOP <br /> DISCREPANCIES TO REPRESENTATIVE.ANY MINOR ERRORS AND OMISSIONS IN THE <br /> I. <br /> OPTIONAL DOWNTILT BRACKET ,�Q RRUS CAN ONLY BE PAINTED ON SUNSCREEN .- <br /> DRAWINGS AND SPECIFICATIONS DOES NOT EXCUSE THE CONTRACTOR FROM 12.04" 7.008" <br /> COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE PIPE MOUNT(TYP) MFR'S STANDARD1111111 <br /> INTENT OF THESE DOCUMENTS, \ •Iy1 <br /> VALMONT MICROFLECT PART#B1001 MOUNTING PIPE MOUNTING �� <br /> OR APPROVED EQUAL BRACKETS ',I I <br /> 3. CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM (TYP) r <br /> LENGTHS OF CABLE TRAYS AND ELECTRICAL LINES AND ANTENNA MOUNTING. - PARTS: <br /> 4. VERIFICATION THAT EXISTING TOWER/POLE CAN SUPPORT THE PROPOSED L�H © ITEM QTY DESCRIPTION ` ._.AO L J <br /> ANTENNA,COAX&ADDITIONAL EQUIPMENT LOADING IS TO BE DONE BY OTHERS. 0 1 ADAPTER,POLE,LOWER (l41.. VERI1 <br /> 1`� 0 1 BRACKET,DOWNTILT,POLE i <br /> , iy o <br /> 00 <br /> 1 BRACKET,DOWNTILT,ANTENNA RRUS N N <br /> 0 O Q 6 1/2 X 1 HEX HEAD BOLT <br /> PANEL © 6 1/2 SPLIT WASHER <br /> O ANTENNA 0 2 1 5/16X 1 HEX HEAD BOLT ISOMETRIC VIEW <br /> 0 O OP) 0 2 5/16 SPLIT WASHER ILL <br /> 0 4 112"THREADED RODRRU WITH <br /> o 8 1/2"SPLIT WASHER <br /> e e e e SUNSHIELD professional D¢rvlCes <br /> 1. 12 1/2"NUT FRONT SIDE <br /> OMMIIIMP <br /> GENERAL NOTES ANTENNA MOUNTING HARDWARERRUS 32 MOUNTING DETAIL <br /> 1 NOT TO SCALE 2 NOT TO SCALE 3 NOT TO SCALE NEW W VE <br /> ARCHITECTURE <br /> DIPLEXER NOTE: <br /> 1. DIPLEXERS MOUNTED AT ANTENNAS. COMPLETE KIT ASSEMBLY: <br /> 2. CONTRACTOR TO VERIFY WITH MFR.BY SITE PRO 1, <br /> MANUFACTURER SPEC's FOR MOUNTING I I - PART#PRK-1245L OR 1133 184TH STREET SW <br /> DETAILS. krk APPROVED EQUAL SUITE 202 <br /> PANEL ANTENNAS 3. DIPLEXER DETAIL AS SHOWN AS A REINFORCEMENT 1 LYNNWOOD,WA 98087 <br /> REFERENCE AND IS SUBJECT TO CHANGE. KIT ANGLE `NIA,. OFFICE:(425)778-3800 <br /> 4. PLATFORM SHOWN AS TYPICAL.VERIFY ' ti JAY VNEWWAVEARCH.COM <br /> ACTUAL CONDITIONS IN FIELD. <br /> r <br /> RING MOUNTDATES 9-8-17 <br /> ARM <br /> PREPARED BYE YML <br /> \, DIPLEXERMOUNTINGAPPROVED BYE JYS <br /> PLATEIySUBMITTALS <br /> DOWN-TILTNO DATE DESCRIPTKM7BRACKETS <br /> 1 1 vi----,--10. --- <br /> 0h, ----El— <br /> kit <br /> I <br /> REFER TO DETAIL-A *� kW!I <br /> U-BOLT < "4 <br /> CONNECTION DIPLEXER NOTE: <br /> TO ANTENNA ASSEMBLY DETAIL PROVIDED FOR INFORMATIONAL PURPOSES ONLY.ALL PRODUCTS LISTED ARE <br /> INCLUDED IN REINFORCEMENT KIT.VERIFY WITH MANUFACTURER DOCUMENTATION PRIOR TO <br /> MOUNT <br /> ASSEMBLY.SUBSTITUTIONS UPON CLIENT APPROVAL CONTRACTOR TO VERIFY PRIOR TO 9-8-17 FINAL PERMIT <br /> DETAIL-A CONSTRUCTION. <br /> -----��� 8-15-17 PRELIMINARY PERMIT <br /> 4 DIPLEXER MOUNTING DETAILS r (MONOPOLE REINFORCEMENT KIT <br /> NOT TO SCALE —51MONOPOLE <br /> TO SCALE REGISTERED <br /> ARCHITECT <br /> 9.8.17 <br /> r.Fize. <br /> OF WAS' <TON <br /> SITE <br /> SEA-HWY 526 <br /> IMOD.SITE I <br /> 9810 19TH AVE SE <br /> EVERETT,WA 98208 <br /> SHEET TITLE <br /> DETAILS <br /> ) _ SHEET NUMBER <br /> gPO A-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.