Laserfiche WebLink
Interior Lighting - Spac 3y-Space Method ,: LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Dr.Mark Stivers Date 9/27/2017 <br /> Calculation 0 0 Addition- Q Addition For Building Department Use <br /> Area NOTE a stand alone +existing <br /> O Spaces where<50%of Q Spaces where z 50%of Q <br /> luminaires are replaced luminaires are replaced <br /> LPA Q Standard Q Additional Efficiency Package Option Q <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage"OTE' <br /> Location(plan#, Height""" Gross Interior Allowed Watts Allowed <br /> room#) Space Type 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Waiting Room Lobby:all other 169 0.720 122 <br /> Reception/ Office:Open plan 324 0.780 252 <br /> Business Office <br /> Xray Health care facility:Imaging room 59 1.060 63 <br /> Hallway Corridor:all other 427 0.530 227 <br /> Exam Room 1-4 Health care facility:Exam/treatment 670 1.330 891 <br /> Restrooms Restroom:all other 143 0.780 112 <br /> Private Office Office:Enclosed 146 0.890 130 <br /> Staff Lounge Lounge/breakroom:all other 166 0.580 96 <br /> Laundry Laundry/washing area 51 0.480 24 <br /> Utility/N20 Closet Electrical/mechanical 43 0.760 33 <br /> Lab Laboratory for medical/industrial/research 143 1.450 207 <br /> Total Area 2340 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 2156 <br /> Proposed Lighting Wattage'" <br /> Location(plan#, Number of Watts/ ji NOTE 4,5,6 NOTE? Watts <br /> - <br /> room#) Fixture Description Fixtures Fixture Proposed <br /> A7.00 LED 2X4 RECESSED DIRECT/INDIRECT 13 61 b%' 793 <br /> A7.00 LED 2X2 RECESSED DIRECT/INDIRECT 4 35 s y ' e 140 <br /> A7.00 R1:RECESSED LED DOWNLIGHT 37 11 ,q 4 407 <br /> A7.00 R2:RECESSED LED DOWNLIGHT 2 16 .2',1,",, iii /P 32 <br /> A7.00 R3:RECESSED LED DOWNLIGHT 10 14 <br /> s'' i ' 140 <br /> A7.00 P1:DECORATIVE PENDANT 4 50 ) 200 <br /> A7.00 W1:LED WALL SCONCE 2 20 40 <br /> A7.00 W2:LED UP/DOWN WALL SCONCE 1 201 4 20 <br /> A7.00 UNDERCABINET LED 5 16 " 80 <br /> A7.00 LED WALL WASHER 1 11 . ,„s K ,: 11 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1863 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting de✓e. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the MaximurrAllowed ' hting Wattage. <br /> Note 9-Calculation Area Details: 7 <br />