My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10031 19TH PL W 2019-06-11
>
Address Records
>
19TH PL W
>
10031
>
10031 19TH PL W 2019-06-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/11/2019 3:55:58 PM
Creation date
6/11/2019 3:55:53 PM
Metadata
Fields
Template:
Address Document
Street Name
19TH PL W
Street Number
10031
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br /> Title Block Line 1Project Title: <br /> You can change this area Engineer: Project ID: <br /> using the"Settings"menu item Project Descr: <br />• and then using the"Printing& <br /> Title Block"selection. <br /> Title Block Line 6 Printed:9 JUN 2017.5119PM <br /> Cantilevered Retainin Wall File=c:\Users\Owner\Desktop\Proiects12017\newlret-wall.ec6 <br /> g ENERCALC,INC.1983-2017,Build:6.17.3.17,Ver:6.17.3.17 <br /> Lic.#:KW-06003603 Licensee:REED&ASSOCIATES <br /> Description: 7'-6" • <br /> Criteria Soil Data Calculations perAC1 318-14, ACI 530-11,IBC 2015, <br /> Retained Height = 7.50 ft Allow Soil Bearing = 2,000.0 psf CBC 2016,ASCE 7-10 <br /> Wall height above soil = 0.50 ft Equivalent Fluid Pressure Method <br /> Slope Behind Wall = 0.00:1 Heel Active Pressure = 35.0 psf/ft <br /> Height of Soil over Toe = 0.00 in Toe Active Pressure = 30.0 psf/ft <br /> Water height over heel = 0.0 ft Passive Pressure = 200.0 psf/ft <br /> Vertical component of active Soil Density,Heel = 110.00 pcf <br /> Lateral soil pressure options: Soil Density,Toe = 110.00 pcf <br /> NOT USED for Soil Pressure. Friction Coeff btwn Ftg&Soil = 0.400 <br /> NOT USED for Sliding Resistance. <br /> NOT USED for Overturning Resistance. Soil height to ignore <br /> for passive pressure = 12.00 in <br /> Surcharge Loads Lateral Load Applied to Stem Adjacent Footing Load <br /> Surcharge Over Heel = 0.0 psf Lateral Load = 0.0 plf Adjacent Footing Load = 0.0 lbs <br /> Used To Resist Sliding&Overturning ...Height to Top = 0.00 ft Footing Width = 0.00 ft <br /> Surcharge Over Toe = 0.0 psf ...Height to Bottom = 0.00 ft Eccentricity = 0.00 in <br /> Used for Sliding&Overturning • <br /> Wall to Ftg CL Dist = 0.00 ft <br /> Axial Load Applied to Stem Footing Type Line Load <br /> •Axial Dead Load = 450.0 lbs BaseatBack of Wall <br /> l ll Soil = 0.0 ft <br /> Axial Live Load = 750.0 lbs Wind on Exposed Stem = 0.0 psf at of Wall <br /> Axial Load Eccentricity = 0.0 in Poisson's Ratio = 0.300 <br /> Design Summary Stem Construction Top Stem 2nd 3rd <br /> Stem OK Stem OK Bar Lap/Emb <br /> Wall Stability Ratios Design Height Above Ftg ft= 5.33 3.33 0.00 <br /> Overturning = 2.08 OK Wall Material Above"Ht" = Concrete Concrete Concrete <br /> Sliding = 0.78 OK Thickness in= 8.00 8.00 8.00 <br /> Slab Resists All Sliding! Rebar Size = # 5 # 5 # 4 <br /> Total Bearing Load = 3,188 lbs Rebar Spacing in= 32.00 16.00 9.00 <br /> ...resultant ecc. = 2.33 in Rebar Placed at = Edge Edge Edge <br /> Design Data <br /> Soil Pressure @ Toe = 1,029 psf OK fb/FB+fa/Fa = 0.030 0.111 0.553 <br /> Soil Pressure @ Heel = 565 psf OK Total Force @ Section lbs= 131.8 486.9 1,575.0 <br /> Allowable = 2,000 psf • Moment....Actual ft-I= 95.4 676.8 3,937.5 <br /> Soil Pressure Less Than Allowable <br /> ACI Factored @ Toe = 1,331 psf Moment Allowable ft-I= 3,147.1 6,114.9 7,122.4 <br /> ACI Factored @ Heel = 731 psf Shear Actual psi= 1.8 6.6 21.0 <br /> Footing Shear @ Toe = 26.0 psi OK Shear Allowable psi= 67.1 67.1. 75.0 <br /> Footing Shear @ Heel = 10.6 psi OK Wall Weight psf= 100.0 100.0 100.0 <br /> Allowable = 75.0 psi Rebar Depth 'd' in= 6.19 6.19 6.25 <br /> Sliding Calcs Slab Resists All Sliding! Lap splice if above in= 12.00 12.00 12.00 <br /> Lateral Sliding Force 1,204.9 lbs Lap splice if below in= 12.00 12.00 8.40 <br /> Hook embed into footing in= 12.00 12.00 8.40 <br /> Concrete Data - <br /> fc psi= 2,000.0 2,000.0 2,500.0 <br /> Fy psi= 60,000.0 60,000.0 60,000.0 <br /> Load Factors <br /> Dead Load 1200. <br /> Live Load 1.600 <br /> Earth,H 1.600 <br /> Wind,W 1.600 <br /> Seismic,E 1.000 <br />
The URL can be used to link to this page
Your browser does not support the video tag.