Nei NorthWest Tower Engineering <br /> g g <br /> WSDOT Monopole, Everett, WA Report No. 180636.08 January 30, 2018 <br /> Wind Load Specifications <br /> A rigorous structural analysis was performed using the provisions of the current design <br /> standard, TIA-222-G, "Structural Standard for Antenna Supporting Structures and Antennas." <br /> This standard is referenced in the 2015 International Building Code (IBC). The minimum basic <br /> wind speed of 85 mph (Vaud, 3-second gust) as listed in the standard for Snohomish County was <br /> used. A basic wind speed of 30 mph in combination with a design ice thickness of W as listed in <br /> the standard was also considered. Exposure Category B (suburban or wooded area), <br /> Topographic Category 1 (flat or rolling hills) and Structure Class III (essential facility) were used <br /> for the analysis. <br /> Wind loads calculated using a basic wind speed of 85 mph (Vag) with a wind load factor of 1.6 <br /> and importance factor of 1.15 for Class III structures per the TIA-222-G standard are similar to <br /> those calculated using an ultimate design wind speed of 115 mph (V,,1) for Risk Category IV <br /> with wind load and importance factors of 1.0 per the 2015 IBC and ASCE 7-10 standard. <br /> Analysis Method <br /> A three-dimensional finite element model of the tower was created using tnxTower Version <br /> 7.0.7.0 (Tower Numerics, 2016). This computer software program calculates and distributes <br /> wind and ice loads in the model. It calculates the resulting forces (required strength) in all <br /> structural members, and determines tower deflections and foundation loads. Required strength <br /> of each structural member is compared to each member's design strength determined using the <br /> TIA-222-G standard. <br /> WSDOT requires that strength ratios in all structural members be kept below 90%. <br /> Analysis Results <br /> The following ratios of required strength to design strength for the tower's structural members <br /> were found: <br /> MEMBER STRENGTH RATIO <br /> Elevation Existing Configuration Proposed Configuration <br /> Member <br /> (ft) Maximum % Capacity Maximum % Capacity <br /> Monopole Shaft 37 37 <br /> 150 0 Base Plate 51 52 <br /> Anchor Rods 53 53 <br /> The attached tables contain more detailed lists of member forces and capacities. For both <br /> appurtenance configurations, strength ratios are below the WSDOT limit of 90%. <br /> Seismic calculations were performed using the equivalent modal analysis procedure as set forth <br /> in Section 2.7 of the TIA-222-G standard. Seismic forces on each section of the pole were <br /> calculated. The capacities of each structural member were found to be adequate when the <br /> seismic forces were distributed as specified over the full height of the tower. <br /> NorthWest Tower Engineering www.nwtower.net <br /> 2210 Hewitt Ave,Suite 209,Everett,WA 98201-3767 y Tel 425-258-4248 Fax 425-258-4289 <br />