3202 20TH ST CINGULAR WIRELESS ANTENNA 2019-06-12
>
Address Records
>
20TH ST
>
3202
>
CINGULAR WIRELESS ANTENNA
>
3202 20TH ST CINGULAR WIRELESS ANTENNA 2019-06-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2019 7:31:15 AM
Creation date
6/12/2019 7:31:10 AM
Metadata
Fields
Template:
Address Document
Street Name
20TH ST
Street Number
3202
Tenant Name
CINGULAR WIRELESS ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EQUIPMENT CHASSIS/ <br /> GROUNDING BUSS BAR/ (2)3/8"0 SS HEX NUT HYLUG CONNECTOR INSTALLATION 411.11* <br /> INSTRUCTIONS: !�• ..IAII <br /> CABLE RACEWAY (#2)TWO HOLE 1. SELECT PROPER HYLUG FOR THE WIRE SIZE USED. ` M tR t <br /> COMPRESSION LUG 2. STRIP CABLE OF INSULATION TO A LENGTH EQUAL `�'----....00/„....„ . vt <br /> GROUND WIRE STUD(TYP OF 2 @ TO THE BARREL OF THE CONNECTOR. Your world. Delivered. <br /> NO-LUX ANTI-OXIDIZING iL- <br /> I,fir. FRONT AND BACK OF CABINET) 3. INSERT CABLE FULLY INTO CONNECTOR. <br /> COMPOUND 4. APPLY THE PROPER NUMBER OF CRIMPS AS <br /> SHOWN BY NUMBER OF COLORED BANDS. <br /> CLEAR HEAT SHRINK ON 5. CRIMP FROM TONGUE END OF CONNECTOR =PLANS PREPARED BY: <br /> COMPRESSION LUGS TOWARD CABLES FOR TERMINALS AND CENTER <br /> #2 STRANDED GREEN SPLICE TOWARD CABLE FOR BUTT SPLICES <br /> kill 3!8"0 STAR WASHERtill INSULATED COPPER GROUND REQUIRING MORE THAN ONE CRIMP PER END. ti�0 E Ot 32rCME <br /> N. LEAD TO BUSS BAR OR#2 HYLUG TYPE YGA CONNECTOR IS PRE-FILLED WITH 16928 WOODINVILLE-REDMOND RD NE,SUITE 210 <br /> SOLID BARE TINNED COPPER PENETROX COMPOUND AND STRIP SEALED. WOODINVILLE,WA98072 <br /> PLAN TO(E)GROUNDING SYSTEM PHONE:425.487.1732 <br /> BURNDY HYDRAULIC DIE SET#U1CRT-1/U11T. WWW.CORNERSTONE-ENGR.COM <br /> NOTE: =PROJECT INFO: <br /> FOR GROUNDING CONNECTIONS TO PAINTED CABINETS <br /> CHASSIS,GRIND OFF ALL ENAMEL COATINGS TO BARE METAL WA2821 <br /> AT LUG CONTACT AREA PRIOR TO MAKING BOLTED LUG <br /> CONNECTION.APPLY NO-LUX TO ALL EXPOSED BARE METAL. EVERETT WALNUT <br /> 3200 20th STREET <br /> NOT USED 12 NOT USED 11 GROUND LUG CONNECTION 9 EVERETT,WA 98201 <br /> 22x34 SCALE:NTS I11x17 SCALE:NTS 22x34 SCALE:NTS 111x17 SCALE:NTS 22x34 SCALE:NTS • 111x17 SCALE:NTS SNOHOMISH COUNTY <br /> [REV::DA <br /> ISSUED FOR: IGROUND BAR ATTACHMENT: COAXIAL GROUND KITS W/ CONSTRUCTION JLONG BARREL COMPRESSIONCONCRETE SUBSTRATE: (4)3/8"0 HILTI TZ EXPANSION ANCHORS DOUBLE LUGS,ATTACH TOTE:—ISSUED FOR: BY:_ <br /> WITH 2"MINIMUM EMBEDMENT. GROUND BAR&INSTALL BY <br /> ANTENNA CONTRACTOR <br /> WOOD FRAMED SUBSTRATE: (4)3/8"0 LAG SCREWS WITH 2"MINIMUM (CADWELD TYPE-GL) <br /> EMBEDMENT(ADD BLOCKING IF <br /> NECESSARY. <br /> CLEAR HEAT SHRINK -4"x 24"x 1/4"THK COPPER <br /> SOLID CMU WALL: (4)3/8"0 HILTI TZ EXPANSION ANCHORS ON COMPRESSION LUGS GROUND BAR.INSTALLED Q 02-13-18 FINAL DMO <br /> WITH 2"MINIMUM EMBEDMENT. BY GENERAL CONTRACTOR <br /> HOLLOW CMU WALL: (4)3/810 HILTI HIT HY-20 WITH HIT-A O O Qq 02-07-18 PRELIMINARY JRF <br /> STANDARD RODS.(3 3/8"EMBEDMENT) 0 0 0 0 0 0 . 0 0 0 0 0 0 0 0 0 0 0 0 0 <br /> DRAWN BY:=CHK.: APV.: <br /> 4 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 (� <br /> NOTE: PROVIDE ELECTRICAL •'i ;0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 •� O I a L JRF I MWO I MWO <br /> COAT ALL MECHANICAL CONNECTIONS ISOLATORS @ • 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 •] CURRENT ISSUE DATE: <br /> W!"NO-LUX'OR APPROVED EQUAL CONNECTION(TYP) <br /> o 11111111111111111111111111 0 02-13-18 <br /> I I [LICENSURE: <br /> 1 FIELD VERIFY <br /> -#2 SOLID BARE TINNED SLt y <br /> of O <br /> COPPER WIRE CADWELD(TYPE-GL)_7" uric! <br /> iolt <br /> TYPICAL GROUND BUSS BAR CONNECTIONS N� i <br /> 22x34 SCALE:NTS I11x17 SCALE:NTS 7 �°NALEE0 Z.((c'/t <br /> =JURISDICTIONAL APPROVAL: <br /> I <br /> ir---=::: a._ ,,,,,,,,,. ,:,,,,,,_,(-0, <br /> • 4 <br /> ` �+j TYPE GL LUG <br /> TYPE GR /” <br /> ......„ir. <br /> TYPE PT _PROPRIETARY INFORMATION: <br /> j�_`:� • ri. <br /> DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY <br /> 1111. _��i ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY <br /> ry -._-- ERRORS ANO OMISSIONS.ED PREVIOUS ISSUES OF THIS <br /> � •• � DRNFOR ATE N CONT I ED BYIN THE LASET OF OCUM N. <br /> -�`/ THE INFORMATION CONTAINED IN THIS SETOF DOCUMENTS <br /> IS PROPRIETARY BY NATURE.ANY USE OR DISCLOSURE <br /> OTHER THAN WHICH <br /> STR STRICTLYS PROHIBITED.PROHIBITED.ELATED TO NAMED CLIENT IS <br /> TYPE GT TYPE SS ,'• DRAWING TITLE: <br /> TYPE VS <br /> DETAILS <br /> NOTE: <br /> [DRAWINGGROUNDING <br /> NUMBER: <br /> CADWELD"TYPES"SHOWN ABOVE ARE EXAMPLES-CONSULT <br /> WITH PROJECT MANAGER FOR SPECIFIC TYPES OF CADWELDS <br /> TO BE USED FOR THIS PROJECT. <br /> E-1 . 1 o <br /> CADWELD DETAIL 4 NOT USED 3 NOT USED D /(322x34 SCALE:NTS 111x17 SCALE:NTS 22x34 SCALE:NTS I11x17 SCALE:NTS 22x34 SCALE:NTS 111x17 SCALE:NTS 1------ CEI JOB NUMBER: LTE 5C 8G 17-09211 <br />