3003 W CASINO RD 2017 BLDG 40-58 Plans 2022-11-09 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-58
>
Plans
>
3003 W CASINO RD 2017 BLDG 40-58 Plans 2022-11-09 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 10:29:26 AM
Creation date
6/14/2019 8:56:02 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-58
Permit
M1709-078
Year
2017
Notes
INSTALL DUCTWORK ASSOCIATED WITH PACV 3 AND 4 ALONG W EF 51 AND 52
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
P2P MAKE-UP AIR UNIT SCHEDULE- PAINT/PREp BOOTFi#2 <br /> CALLOUT SUPPLY FAN FILTER N4T WATER COIL ELECTRICAL BASIS OF DESIGN <br /> TOTAL MAX MOTOR[9] <br /> � MIN SUF'PLY DRIVE CFM MAX MAX CON7ROL BRANCH <br /> AIRFLOW AIR �AN TYPE PER E.S.P. (IN RPM I�AX VEL HHW FLUlD 7YPE WPD VALVE PD PIPE SIZE <br />' TYPE MARK LOCATION SERVICE (CFM) [2] (CFM) TYPE [8] FAN [1j WC) [3] QTY [1] RPM HP BHP [5] TYPE [4� (FPM) EAT LAT EWT GPM [1] [7] (FT) (PSI) (IN) VOLTAGE F'HASE FFtEQUENCY MANUFACTURER MODEL NOTES <br /> MAU 06 P2P-CONTROL ROOM CORRIDOR P2P-DOGHOUSE 3 &4 1800 1800 FC �ELT 1800 1.65 1 2268 1800 3.0 2.5 MERV 8/MERV 13 500 27 °F 77 °F 135 °F 5.7 0% 0.9 10 1 1/2" 460 3 60 CARRIER 39MN [6] [10] <br /> SCHEDULE NOTES: <br /> [1]WITH UNIT AT MAXIMUM CONDITIONS <br /> [2] MINIMUM UNIT AIRFLOW, FOR GENERAL EXHAUST MAK�UP AIR. S�E SEQUENCE OF OPERATION. <br /> [3} STATIC PRESSURE EXTERNAL TO UNIT, DOES NOT INCLUDE DIRTY FILTER ALLOWANC� <br /> [4] 2" MERV 8 FILTER& 12" MERV 13 FILTER <br /> [5] MAXIMUM ALLOWABLE MOTOR �RAKEHORSEPOWER AT MAX FLOW AND 7SP <br /> [6] MAXIMUM RADIATED SOUND POWER LEVELS OF THE UNIT SHALL NOT �XC�ED 85 d�A <br /> [7] WATER ENTERING WITH ETHYLENE GLYCOL AT THE PERCENTAGE NOTED <br /> [8] PROVID�WITH INITIAL SET OF SHEAVES FOR FAN(S) TO MEET CONDITIONS AS SCHEDULED. FOLLOWING INSTALLATION AND BALANCING, PROVIDE REPLACEMENT SET OF SHEAVES FOR ACTUAL CONDITIONS, REGARDLESS OF WHETHER CONSTANT OF VARIABLE SPEED FAN(S)" <br /> [9� PROVIDE VFD RATED MOTOR, SEE ELECTRICAL DESIGN FOR VFD SPECIFICATIONS. ELETRICAL TO PROVIDE VFD, VFD TO BE �IELD INSTALLED <br /> [10] PROVIDE MANUFACTURER INSTALLED TERMINAL JUNCTION �OX ON EXTERIOR QF UNIT CASING INCLUDWG ALL WIRING NECESSARY FOR VFD OPERATION AND GONTROL. PROVIDE ONE JUNCTION BOX PER VFD. : <br /> AIRFLOW CAPACITY LIMI`fS (CFM) NOMINAL SIZE (!N) NECK DIMENSIONS (IN) BASlS OF DESIGN <br /> FOR RECTANGULAR MAX TSP DROP � <br /> CALLOUT AIR TERMINAL DESCRIPTION MAXIMUM MINIMUM LENGTH WIDTH DIAMETER LENG7H WIDTt� MAX NC (IN.W.G.) MATERIAL OND FINISH MANUFACTURER M�DEL NOTES <br /> SG-1 SIDEWALL MOUNI'ED ADJUSTABLE DUAL DEFLECTION SUPPLY GRILLE 360 360 10" 14" 8" 12° 20 0.05 ALUMINUM Yes #26 WHITE TITUS 300FL <br /> EG-1 SURFACE MOUNTED EXHAUST GRILLE 200 200 10" 14" 8" 12° 20 0.02 ALUMINUM Yes #26 WHiTE TITUS 350FL <br /> RG-1 SIDEWALL MOUNTED RETURN GRILLE 215 215 10" 14° 8" 12" 20 OA2 ALUMINUM Yes #26 WHITE TI7US 350FL <br /> SD-3 MO�ULAR CORE SQUARE CEILING DIFFUSER 350 226 24° 24" 10" 10" 17 0.03 STEEL No #26 WHITE TITUS MCD <br /> P2P VAV BOX SCHEDULE- SPRAYIPREP BDOTH#2 <br /> AiRFLOW <br /> CALLOUT SETPOINT ELECTRIC REHEAT COIL DUC7 CONNECTIONS ELECTRICAL �,4SIS OF DESIGN <br /> ENTERING CAPACITY <br /> MIN INLET HEATINt� AIR DRY CONTROL pRIMARY OUTLET DIMENSIONS <br /> EQUIPMENT DESIGN MIN STATIC CAPACITY BUL� (DEG CONTROL Alft INLET <br /> TYPE MARK LOCATION SERVED FLOW FLOW PRESSURE KW F) TYPE DIAME7ER tiEIGHT WIDTH VOLTAGE PWASE FREQUENCY MANUFACTURER MODEL NOTES <br /> VAV 6 CONTROL ROOM LEVEL ACU-28 800 800 0.35 5 55 SCR 8" 10" 8" 277 1 60 ENVIROTEC SDR-8-EH <br /> , <br /> � <br /> ; <br /> f <br /> 900 SW 16th Street Suite 307 FSi consulting engineers <br /> Renton, Washington 98057 Sotutions & Service <br /> � <br /> ACCEPTABILITY DRAWN DATE SUBTffLE CURRENT REVISION SYMBOL DATE <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE � <br /> NJH 01(10/17 HVAC EQUIPMENT SCHEDULES <br /> W2548317 2 01/10/17 � <br /> 0 Issue For Construction FSi BSC 03/08/16 �� W• t qN THIS DESIGN AND/OR REpCKED 01I10117 SHEET � <br /> Q- �w^�,, SPECIFICATION 15 APPROVED � <br /> 1 Revision-Release 44 FSi BSC 06102/16 � � y o <br /> a �P�� `�'f ENGINEER TITLE <br /> Z APPROVED BY DEPT. DATE BSC O'I/'IOI'I7 Boeing 777X CWC BUILDING � <br /> P � FR M2v� � <br /> 2 Revision-Release 59 FSi BSC 01/10/17 A �.Ye� CHECKED � <br /> °�FSS,aHA��ti����� REp��E� B U I LD I N G 40�V V JOB NO. COMP NO. t <br /> APPROVED 4O-5H-M�Va Q <br /> ov�o��� MECHANICAL MASTER EVERETT, WA °WG NO. 40-58-M2va <br /> � <br />