Laserfiche WebLink
� . _ - _ <br /> _ _ i -_ <br /> Buildinq Information Material Specifications� ' <br /> . pr � � <br /> z <br /> Building Width: _49'-6" Front Eave Ht.: � 19'-8" 1. Primary Framing: 5. Bracing and Columns: 00 � � <br /> Building Length: _79'-6" Back Eave Ht.: _ 19'-8" Web Plates, ASTM A529, A572, A1011, Grade 55 Pipe, ASTM A53 Grade B, Min. Yield 35 ksi. � o , � _____ <br /> Flanges, ASTM A529, A572, Grade 55 Round HSS, ASTM A500 Grade B, Min. Yield 42 ksi. � � � <br /> Rect. HSS, ASTM A500 Grade B, Min. Yield 46 ksi. Z � � <br />� Roof Panel Type: _ (BY OTHERS) Roof Color: _ (BY OTHERS) 2, Secondary Framing: � `r' W � W �' <br /> Wall Panel Type: _ (BY OTH ERS) Wall Color: _ (BY OTH ERS) Galvanized 16Ga, 15Ga. 14Ga, 13Ga, 12Ga, ASTM A653 G90, 6. Bolts: � U �_ � _ <br /> Roof Trim Color: _ (BY OTHERS) Wall Trim Colar: _ (BY OTHERS) Grade 55, Min. Yield 55 ksi. High Strength Bolts, ASTM A325-N, Washer under -, -- - <br /> turning element. Machine Bolts, ASTM A307. �' <br /> 3. Roof & Wall Coverin : Anchor Bolts (Not By CBC) Sized Based on N � � � <br /> 26Ga Painted and Un ainted ZA., ASTM A792 AZ50, Grade SO & 80 A36 Material. ' z = <br /> p Q � � z <br /> 24Ga Painted and Unpainted ZA., ASTM A792 AZ50, Grad� 50 � � __ W _____ <br /> 26Ga Painted Galvanized, ASTM A653 G90, AZ55 Grade 50 & 80 7. Shop Coating: � <br /> 24Ga Painted Galvanized, ASTM A653 G90, AZ55 Grade 50 All Steel members except galvanized secondary W <br />��; framing, cables, bolts and screws shall receive � <br /> . 4. Bracing: one shop coat. - <br /> Cables, ASTM A475 Extra High Strength Grade. op <br /> Angles, ASTM A36, Min. Yield 36 ksi. tt') <br /> Rods , A529 Grade 50 c� <br /> z �' <br /> Product Certifications De�ign Loads O � <br /> _ <br /> 1. IAS International Accreditation Services, Inc. This steel building is designed utilizing the following loads, Q � � <br />� Approved Fabricator AC-472, MB-152. in compliance with the pertinent provis�ons of the International � Q <br /> Building Code, 2012 Edition (IBC 2012). � J <br /> 2. City of Los Angeles, CA. Approved p � <br /> Type I Fabricator No. 1436. All accessories such as doors, windows, etc. not by CBC Steel � �p <br /> Bu�ldings, must be designed as Structural Components in _ � <br /> 3. City of Riverside, CA. Approved accordance with the W�nd Load provisions of the applicable .� z <br /> Type I Fabricator No. SP07-0091. Cc�des and Specifications referenced on this page. , � -- <br /> uJ � � . <br /> 4. Clark County, Approved The Builder and/or the Engineer of Record must confirm that z � � <br /> Steel Fabricator No. 404. the following loads meet the requirements of the local building W � � <br /> department. CBC Steel Buildings and the undersigned are "NOT C� d � <br /> Codes & Specifications the Engineer of Record for the entire project. C„� � <br /> �� <br /> The design of this structure is in compliance � � <br /> with the CB� specifications and standards, � o � <br /> � utilizing the pertinent provisions and B�ailding Dead Load 7.0 psf � O a � <br /> recommendations o f the following Co des. C o l l a t e r a l L o a d 5.0 p s f _� = o L 1.� <br /> L i v e L o a d 2 0.0 p s f 1 --�--- . <br /> Live Load Reduction Allowed Yes � � o a�� � <br /> 1. I n t e r n a t i o n a l B u i l d i n g C o d e, o ry � N ' i <br /> 2 0 1 2 E d i t i o n (I B C 2 0 1 2). Srow Load, Roof 0.0 psf a o Q o , I <br /> Ce 1.0 --- I___----�- <br /> 2. American Institute of Steel Construction, Impt. Factor 1.0 E..r;:L � <br /> � i., � a� <br /> Fourteenth Edition (AISC 360-10 & AISC 341-10). . i � ;=1� <br /> � V�f;nd Load, Speed _ 0.0 mph - ��� <br /> z'� �x_ osu re C �. �� �� <br /> �y�� 3. Am�rican Iron and Steel Institute, � �.,. :�, L �- <br /> „ � 2010 Edition (AISI S100-07/SI-10). Impt. Factor 1.0 ^T^ °� <br /> �., <br /> . < i �� <br /> K%t 1.0 � "' . <br /> 4. Metal Buildin Manufacturers Association, �e�-�� � � '' <br /> g E a r t h u a k e �o a d: u � = <br /> 2012 Edition (MBMA, 2012). Q �- � � �� �,,.� <br /> S e i s m i c D e s i g n C a t e g o r y: D � �_� Z ;�; `;�� <br /> � , � �s �� W`'� <br /> 5. American Weldin Societ Seismic Site Class: D C ' <br /> g y� o o � ... � �� <br /> Structural Welding Code (AWS D1.1, 2008). Coeff. Ss = 143.90 % S1 = 56.00 % �� ��`° <br /> Coeff. R = 3.5 for Moment Frames Omega = 3.0 � i:� ��`s, <br /> ,���y�:� C� i i i° <br /> Coeff. R = 3.25 for Braced Frames Omega = 2.0 � �� � _ °� <br /> F- I'_..L <br /> Inspections Impt. Factor 1.0 � € � J `; <br /> ��� � <br /> � �{�;� , �, ��_ <br /> � �t �� � J �� <br /> 1. Shop Welding inspe�tion is not required ����:� � � ���; � <br /> according to the approved status of the Other �oads: �� � � o ��, <br /> above Certifications. Mezzanine: ; �� ,� �� <br /> Live Load N/A ___ _- `L °^' ___ <br /> No field welding is required by CBC Steel b����� <br /> Dead Load N/A <br /> Buildings. However, if any field welding is Crane Load N/A �`jy <br /> � � required due to any field modifications, �° ��°� P�w � <br /> special inspection is required. � F <<`��', ��'�� � � <br /> � <br /> � <br /> Special Notes � � ��� � � `� � <br /> `o;! ��'�� � <br /> 2. Special inspection is required for high �� �F�s� F�� � <br /> strength bolts. The Turn of the Nut 1. Building will be inside of another building; therfore, no �s��� . <br /> method of tightening is recommended, under sr�ow load or wind load are present. o o � W <br /> t he supervision o f an in depen den t tes ting � � o <br /> laboratory. Alternate methods of tightening 2. Insulated panels are not designed by CBC Steel Buildings. o Q <br /> � � - �-�- <br /> m a y b e u s e d a s p e r m i t t e d i n t h e S p e c i f i c a t i o n I r consi dere d as Stan din Seam Pane l � ~- --}-- -- m- <br /> for Structural Joints Using ASTM A325 or 3. Insulated roof pane s a e g <br /> A490 Bolts (AISC Thirteenth Edition). CBC Steel fc�r purlin design. <br /> Buildings shall not be responsible for �+. Insulated wall panel is considered as Screw-Down Panel for <br /> administration or costs associated with girt design. . <br /> the inspection process. <br /> � Drawin� Status <br /> � Preliminar� <br /> Special Boltinq Connection Inspection Req. These drawings are conceptual only and are not <br /> (Made with A325 Bolts) to be used for the permit or construction process. <br /> _' • N <br /> 1) Pre-tensioning of A325 bolts is required on � For Permit o � <br /> primary framing, bolted bracing, and strut These drawings are Final and are for review by the building � . <br /> connections if located in seismic performance/ official or others. This set is not intended for construction, '� <br /> design category "D", "E" or "F". as piece markings have not been identified, nor is it � <br /> � intended for the ANCHOR BOLT PLAN to be poured. <br /> , 2) Slip critical connections are not required by � <br /> � � <br /> CBC Steel Buildings o '> <br /> 0 For Construction . � <br /> : Erection drawings, identified as "Detailed for Fabrication". �� -�-- - <br /> : � N <br /> a�a�a a�a�al <br />