m
<br /> LEGEND
<br /> 1 .75 1 .80 1 .85 2.00 2.30 2.70 3.00 3.05
<br /> 2A PARTITION TYPE (SEE SHEETS A360 AND A361)
<br /> 25'-0" 30'-0" 30'-0" _ 25'-0" 25'-0" , 25'-0° 30'-0°
<br /> r — � 100 DOOR NUMBER(SEE SCHEDULES A350-A355)
<br /> 7 7'-8" 33'-8° �
<br /> _ _ _ _ _ _ _ _ _ _ _ ` H 2D BRB — L L BRB H � W1 WINDOW NUMBER (SEE ELEVATIONS SHEETA350)
<br /> o �, o T — 2 — — — — — — — — — C
<br /> V ' � y � 8' HIGH WOVEN L1 LOUVER NUMBER(SEE SHEET A352)
<br /> � ( � o �`� 2D � � � -- - 1 G _ 2 C.--- M105B2— I �� W E L D E D W I R E M E S H � �
<br /> � , FENCING SF1 STOREFRONT NUMBER(SEE SHEET A350)
<br /> c �
<br /> ,V � nnEzzANiNE � �, �— ! � � INITIATIVE
<br /> � � � 114'-0" ' � DN I STAIR C2 1D1� � I ST�RAGE I R1 RAILING TYPE (SEE SHEETA513)
<br /> p �—� ' I ��� M101C2 - � M105B2 '� '� �
<br /> ' �SF10> � �G I � EWS EMERGENCY EYE WASH & SHOWER
<br /> �
<br /> � �/ � � I ; - 427 SF EWC ELECTRIC WATER COOLER
<br /> ' - � � I •
<br /> � 1 ( I �N �G M101C2 ' M1C � BRB BUCKLING RESTRAINED BRACE (H = HIGH, L = LOW)(SEE STRUCT.)
<br /> � ( � � 0 1 J � M 1 A10-22 A506 � � � � � �
<br /> � , �� GP GUARD POST
<br /> — — — — — — — — — — — — �_,. — — _I�_—. — — — M 1 A10-22 A465 — — — — — —
<br /> - ' — — — �C.�6 CE COMMUNICATION ENCLOSURES
<br /> CR CARD READER
<br /> 1'-0"E.O.S. - - --- -- -------
<br /> I I �, 2g'-p" 1J ZE D�13 2E � ( � CJ CONTROL JOINT
<br /> i
<br /> M1A10-22 A511' . PB PIPE BOLLARD
<br /> i `"�
<br /> i - PD � PRIMARY DRAIN
<br /> � '
<br /> i �� € CLOUDS INDICATE AREAS �N HOLD
<br /> — —�- — — — — —�— — — — — —�— — — — — —�- I— — � — — — — —�- — — — —I— — — — — I— — ��.. �
<br /> , �C.25) �
<br /> ; � �
<br /> �
<br /> � CLOUDS INDICATE REVISION AREAS
<br /> i OVERHEAD HOIST-
<br /> I I � � ( UP FABRIC DOOR � � I
<br /> i DOOR(OHF) ---,� '.
<br /> �
<br /> i - EDGE OF FLOOR ABOVE �
<br /> � GENERAL NOTES
<br /> �
<br /> I I ( i � C OPEN TO BELOW � I
<br /> i M1A10-22 A200 � - � ALL CONTROL JOINTS (CJ) NOT DIMENSIONED SHALL
<br /> �
<br /> i - � BE PLACED AT SIDE OF OPENINGS ON PLAN OR AT
<br /> � I `Y' CENTERLINE OF COLUMNS
<br /> i
<br /> i i-- FLOUR EDGE ABOVE
<br /> i •
<br /> � � ( i � 102C2B � ( � �_� 36"X 36"ACCESS PANEL. SEE 7/A500
<br /> i
<br /> i
<br /> i �3- DIMENSIONS ARE TO FACE OF MASONRY OR FACE �
<br /> � OF STUD UNLESS NOTED OTHERWISE
<br /> i
<br /> � � � i � � � �
<br /> � CONSTRUCTION NOTES
<br /> ,
<br /> — — — — — - —.- - — — — — — r — C.5
<br /> 1 f — — — — — — — — — — — — — — —
<br /> � I�
<br /> � ( � M 1 A10-22 A506 i � 1 J R4 � � �
<br /> i ----------- --- --------- ,
<br /> — — — — — — — — — — — — — _ _ _ _ -_-- — — — — — — — — — — — C.6
<br /> � � � �8 7/8° � 1 G ( I � � �
<br /> � �� _ � � �1G �
<br /> ✓ � ( R4 M
<br /> 1J m� 1G I _ , � , a o .: ., ., , „ , , � , � . _,
<br /> M REFERENCE DRAWINGS
<br /> I I � � m I � DN i pN wI I � 1G I I I
<br /> � (— �— - !
<br /> ��, � ; ' _ � �
<br /> � ��� . ; ' �
<br /> ��.�� � - � ; � FREIGHT � I .
<br /> I I I I ; ' ; ti � I ELEVATOR 3 ' � I I
<br /> �o � - —=;� : il I
<br /> 6 M1A10-22 A 0 m ( � � M�
<br /> � _ I_ 1G M1A10-22 A452 ��
<br /> � , Up � � ,
<br /> — —r — — — — -�— — — — — — — - — -� �� °° _ s =___ ----- �-- �.. — — — — — — — i— — �C.75) _
<br /> — — — — — — — — — � — — � �= 2�� - — - � � ��
<br /> � — � — — — F — —� — — _ — _ — — — _
<br /> M 1 Q2C2 ��
<br /> 1J -, -,-r—\ � AIR D2 1D1 C.77�
<br /> U
<br /> 1G $
<br /> ��
<br /> � � � ��' ' �B M 1 0 2 C 2 � 1D1 � � I
<br /> 1 :., 4. ,i 1., �, ", ,.. ..,. �� .,
<br /> 2E � 5�. � � , _ ,
<br /> ti
<br /> � ��
<br /> SIM � � !r- . 1G i _ 1G , .
<br /> I I 2 , I � � �i (
<br /> � M1A10-22 A500 ' ELEVATOR 4 ;' ' � � � -
<br /> o I 1 B I ",' � �. � ,.s �i �i a , �a �a �a
<br /> N 1J - 2D 2D N � _ , 3'-10'�, � 7�.��� �,
<br /> \�'�T�— A
<br /> 7 � �--` r'-- , � 0 ' 10 11 12 13 14
<br /> 3 � (� — - - - - _ _ - -
<br /> I I I ZD , �;G „ � �./I ' I I � � � � � �
<br /> ! - --- --- ----- -- M103C2
<br /> 15 16 17 18 19
<br /> 6 � � �- - - - - - - - - -
<br /> 2E J "' T NING STOR
<br /> N 1 B C /�%�!/''�j � �
<br /> 7'-9° � 103C2 � 20 21 /22�'��' 23 24
<br /> � ,
<br /> 2 - G — — — %%�%;i;�� — — — — o
<br /> I I i � I � I I I I + + �
<br /> � U H 2 D BRB L L�.mBRB H 25 26 27 28 29
<br /> — — — — — — — — — — — - _ � — — -- - — — — r' — — — — — — — — — -�— D E - - -�— - - -I- - - -I- - - -�— - - E
<br /> 30 31 32 33 34
<br /> I I I I I I I I F - - -I-- - - �-- - - -�— - - - - F
<br /> . �
<br /> - I I I I I ( � I 35 36 37— 3$ 39
<br /> G � � � � - �
<br /> 40 41 42 43 44
<br /> G � � � � � � � � � � � � H
<br /> � �
<br /> 45 46 47 48 49
<br /> � � � � � � � � � � � � � � � � ,
<br /> I v
<br /> 50 51 52 53 54
<br /> CK}f— — � — — � — — � — — � — —�(K)
<br /> � �
<br /> 55 56 57 58 59
<br /> PARTIAL FLOOR PLAN �aa REGISTER=Q �— — � �
<br /> F �
<br /> Grege�Kirken�lall ARC�I T_CT � 60 61— 62 63 64 �
<br /> SCALE: 1/8°= 7�-�° 0928�41 AM�02-0 -2016(-05'00'GMT
<br /> : _...,
<br /> T �
<br /> ��� 10 1.3 1.3 17 ] �0 �1 4 5 0
<br /> n �C' R k R' EI �' ' I t 4 � (,(v
<br /> . STATE OF WASHI�IGTO � 0 4' 8' 16' 24'
<br /> 900 SW 16th Street Su�te 307 �':
<br /> Renton, Washington 98057 SCALE: 1/8��_ ��-o° �
<br /> �
<br /> �
<br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE W A s ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �
<br /> oF N �xM ovzsr�s PARTIAL FLOOR PLAN � �
<br /> ��` ���r THIS DESIGN AND/OR CHECKED W2548317 01/26/16 �
<br /> 10 REVISION -RELEASE 29 KAS GRK 10120l15 5 REVISION-RELEASE 16 CXJ GRK 04/21/15 �P o GRK 01126/16 sHeeT r
<br /> � � SPECIFICATION IS APPROVED
<br /> 11 REVISION-RELEASE 35 KEB GRK 01/26/16 6 REVISION-RELEASE 18 CXJ GRK 05l19/15 � BRPHARCHITECTS ENGINEER TITLE � -
<br /> BOE,�� ENGINEERswC. APPROVED BY DEPT. DATE �RK o��2s��s BOEING 777X CWC BUILDING o
<br /> 2 REVISION-RELEASE 2 CXJ GRK 12/05I14 7 REVISiON-RELEASE 21 JXM GRK 06130115 No.3�3� CHECKED M 1 A 10 22 N ' .
<br /> � BUILDING 40-58 � � �
<br /> 3 REVISION-RELEASE 5 CXJ GRK 01126/15 8 REVISION-RELEASE 22 JXM GRK 07/16/15 m�-� o APPROVED JOB NO. COMP NO. � '
<br /> '�'�,,T ��tiP�`� 40-58-M1A10-22 x �... �
<br /> 4 REVISION-RELEASE 11 CXJ GRK 03/03115 9 REVISION-RELEASE 27(TI PROGRESS) KAS GRK 09122l15 F oF Au�N° APPROVED ARCHITECTURAL MASTER COL, 1.75-3.05/C-D EVERETT, WA °WG"o. 40-58-M1A10-22
<br />
|