<br /> LEGEND
<br /> 1 .75 1 .80 1 .85 2.00 2 2.30 2.70 3.00 3.05
<br /> ' 1A3 A113 2A PARTITION TYPE (SEE SHEETS A36Q AND A361)
<br /> 100 DOOR NUMBER(SEE SCHEDULES A350-A355) �
<br /> I 25'-0" I 30'-0" � 55'-0" I I 50''-0" I 30'-0" I W1 WINDOW NUMBER (SEE ELEVATIONS SHEETA350)
<br /> — � = 17'-2° 6'-9" z �
<br /> — — — — — — — - — — — — -`�-- —, �
<br /> � � ' T — L1 LOUVER NUMBER(SEE SHEET A352)
<br /> v v'�= BRB � 2A � BRB H - �
<br /> C� _ A
<br /> � � � I I 2�, p„ 2A .�, 2„ � I 2A I i I SF1 STOREFRONT NUMBER(SEE SHEET A350)
<br /> �
<br /> � sl ------
<br /> �
<br /> , N SF1 SHAFT � �� " � SF1 N R� RAILING TYPE (SEE SHEET A513)
<br /> O 2 10-52 A500 � � I. O
<br /> ( ( I I ' ( � ( I ( , R9 � EWS EMERGENCY EYE WASH &SHOWER
<br /> � �
<br /> EWC ELECTRIC WATER COOLER
<br /> m ! I ( I m = BRB BUCKLING RESTRAINED BRACE (H = HIGH, L = LOW)(SEE STRUCT.) '
<br /> 2 SIM i _ M
<br /> /� � GP GUARD POST
<br />� 1 J � 2 2A10-52 00 `t � - - —-� � ( R9 I � ( -
<br /> 5 � �_ � M
<br /> � / / / 3 � CE COMMUNICATION ENCLOSURES
<br /> r� 2� 2 � ' CR CARD READER
<br /> � ` ,
<br /> `� CJ CONTROL JOINT
<br /> � � I 2E � 2� I I � I � F1 � I PB PIPE BOLLARD
<br /> � ( � '� 2 � PD PRIMARY DRAW
<br /> 1'-01/2°-� 9�� � � �� � '
<br /> , 15 -5 , � -
<br /> -� �. �' ���`�����
<br /> _ __� _ _ _ _ _� + _ _ _ _ _ o _ �; T , _ _ _ � — _ — �� — — — — — I_ ' — t, � CLOUDS INDICATE AREAS ON HOLD
<br /> �. - J.25�� .
<br /> -� — � _ �
<br /> U - �
<br /> i �� �
<br /> 2D 1 - 2 �� CLOUDS WDICATE REVISION AREAS
<br /> ' I _ COMM J �` � �
<br /> 0 2A10-52 A5
<br /> I `� � 201 J2 � � OPEN OFFICE I _ I
<br /> � �B 201J2 � 204�2 SF1 N GENERAL NOTES
<br /> . r7-1 6 ;
<br /> I I I I 2D - J �B ( � � ; � � ALL CONTROL JOINTS (CJ) NOT DIMENSIONED SHALL
<br /> � � M BE PLACED AT SIDE OF OPENINGS ON PLAN OR AT
<br /> �- '� ' "' -� CENTERLINE OF COLUMNS
<br /> N 2E .� SYSTEMS � �
<br /> ,; "'
<br /> � � '�%� 1 B � 202.12 202J2 l � � �
<br /> � � ( � I � I I �� 36"X 36"ACCESS PANEL. SEE 7/A500. RATED TO
<br /> , � �_� , �, �,, ,_ ., MATCH WALL RATING.
<br /> ;- � t�=�' �^ I,--��, -�
<br /> o OPEN TO BELOW
<br /> � ; r � [ �� � Ti � � �� , 2Q3J2 �
<br /> . 2D — -- n SF1 �,
<br /> � � ELEC RM o 3 �� DIMENSIONS ARE TO FACE OF MASONRY OR FACE
<br /> ,� OF STUD UNLESS NOTED OTHERWISE
<br /> ( � OPEN TO BELOW I I '? 203,12 � � � �
<br /> -,
<br /> g f � � i �
<br /> " �`��c�T--�`�`�`�� � CONSTRUCTIDN NOTES
<br /> , 2A =
<br /> — — — — — — — — — — — — — � � — — — — — — �2A10-52 A520 — � — — — — — — J.rJ
<br /> U U
<br /> I I I 10 I I I I I
<br /> 2A10-52 A500
<br /> o � 7 0
<br /> �, SF1 SF1 �,
<br /> � � ( � 2 �� � � � �
<br /> M
<br /> �I � � 2D 18��6° 15'-2°
<br /> M � 7 ' � FUTU E STAIR OPENING g,, �,
<br /> . � � � 2E ' � � � � � � � REFERENCE DRAWINGS
<br /> � � �� ;� , ,, , � �
<br /> / , �
<br /> I i� z � , / ;i / ' '
<br /> � � _ � ,� � /� /! / SF1 �
<br /> � � � � 2 Si _ � � /� � ,//� � � � � O N , .
<br /> � 2A10-52 A500 : `- w / i� � / �/
<br /> 2D �r � / � f j
<br /> 1J � � ' /� �/
<br /> � _ � //, � /
<br /> _ , i, , � , ,
<br /> — —fi — — — — -t-- — — — — —1— — — � — , -L — — ---t— — — — � �,� — — — — — �— — J.75
<br /> � � � 2A '�
<br /> - � � FUTURE STAIR J2 '] -
<br /> ' I Rg 1 B (
<br /> �
<br /> � � � � SF ' � � � � � � i � `;' � .
<br /> N , 7 � ,
<br /> � ti � �
<br /> I R9 i
<br /> � 1 I � I C� ' I � m I � A 19 Q.3�1.3 1 117� 0 t �5' a 0 A
<br /> .T �.
<br /> . 1J � _,
<br /> M � M � 10 11 12 13 14
<br /> �1i �, 1 ' s�;H — � - - � - - � - - —}— -- - �-(e)
<br /> 8 ri
<br /> � � � � ( � � j � � 15 16 17 18 � 19 �
<br /> a SF1� o cC_lf- — � - - � - - � - - � - - -�-��� ,
<br /> �, SF1 �,
<br /> ' 20 21 22 23 24 '
<br /> � ,1° 6'-7° B 1T �, �„ o — � — — � — _. � _ _ � � , p .
<br /> � � � i 2A10-52 A607-20 � � ( � 25 � 26 27 2s 2s �
<br /> — -' -', H � 59�.4�� 6'-11" i� �" — — � — — � — — � — — � — — {�
<br /> — — — — — — — — — — o � �
<br /> — � — — — — — — — — — — — — —� — E E
<br /> K 30 31 32 33 34
<br /> ( ( I I ( � F � � � � � � � � � � � � � � F
<br /> I � � 35 36 37 38 39 � _
<br /> ( I I i I I I ( G — � — — � — — � — -- � — — —}{c�
<br /> � 40 41 42 43 � 44 '
<br /> H � � � � � � � � � � � � � � �
<br /> (��
<br /> 45 46 47 48 49
<br /> � � � � � � %f///�j � � � � � � .
<br /> // �j I `.
<br /> 50 51 -��52���' 53 54
<br /> G — — — `%�/!�%/i — — — K
<br /> � � � �
<br /> 55 56 57 58 59
<br /> � aa G� ( -
<br /> RcGISTcRtD
<br /> Gre9e�Kirken�iall ARCnIT=CT � 60 61_ 62 63 -64 �
<br /> 09:27`04 AM�02-0 -2016(-05'00'GMT
<br /> PARTIAL FL04R PLAN � �,3 J � — o , 4 � �
<br /> ' � n FC' R k R' Ef:� ' ' I t 4 1 �(r�
<br /> SCALE: 1/8"= 1'-0" N 9�0 SW 16th Street Suite 307 STATE OF WASnINGTON 0 4' 8' 16' 24'
<br /> Renton, Washington 98057 SCALE: 1/8��= ,�-o�� .
<br /> �
<br /> a
<br /> SYM REVISION BY APPROVED DATE SYM REVIS�ON BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE �
<br /> W a S ACCEPTABILITY JXM 01126116 PARTIAL FLOOR PLAN $
<br /> 0 ISSUE FOR CONSTRUCTION JXM GRK 10(09/14 5 REVISION-RELEASE 22 JXM GRK Q7116115 ,�P�` �F N/N�o THIS DESIGN AND/OR CHECKED W2548317 01/26/16 h
<br /> 5 � SPECIFICATION IS APPROVED GRK 01126/16 SHEET � _
<br /> 1 REVISION-RELEASE 1 RVK GRK 10/30114 6 REVISION-RELEASE 25 KEB GRK 08125/15 0 BRPHARCHITECTS ENGINEER TITLE o
<br /> �OES�� E"��"EERs�"�. _ BOEING 777X CWC BUILDING
<br /> APPROVED BY DEPT. DATE GRK 01126116 c�
<br /> 2 REVISION-RELEASE 15 CXJ GRK 04/07/15 7 REVISION-RELEASE 29 KAS GRK 10(20115 N0.3137 CHECKED 2A 10 52 `�
<br /> m� = BUILDING 40-58 �
<br /> 3 REVISION-RELEASE 18(IFC TI) KAS GRK 05119/15 8 REVISION-RELEASE 35 KEB GRK 01t26/16 ;�, .�.o APPRovE� �oa No. connP n�o. �
<br /> 4 REVISION-RELEASE 21 JXM GRK 06130115 /°�r �`�P ow�No. 40-58-ZA10-52 �
<br /> F oF AutH° APPRovE° ARCHITECTURAL MASTER COL. 1.75-3.05/J-K EVERETT, WA 40-5$-2A10-52
<br />
|