Laserfiche WebLink
d <br /> LEGEND <br /> � � ' � SEE LEGEND SHEET 40-58-M1a &40-58-M2a FOR KEY <br /> % \ , , <br /> i�.��.�i i�,��" �j j�,��j SHEET AND GENERAL NOTES. <br /> �-�� �.,,_�/ \___% <br /> � 2 <br /> � <br /> � , , GENERAL NOTES � . <br />� I --- - --2g-. - - - 28-- - - ---TP=40� 1 ----- --I --- - - ----- - - ------- -- - - I --,/ `-~\ REFERS TO KITCHEN EQUIPMENT SCHEDULE. REFER TO <br /> ---- - - -- - <br /> --- - --- - � � ' 1� O FOOD SERVICE PLANS AND MECHANICAL SCHEDULE <br /> ��'T I 24 <br /> ,�,�%"�-----._ ,._. -- . - ------ -- M2t(TYP). <br /> M474 M5 , �� <br /> � ' ( � _ �a� ��� I . � . i �"_ . <br /> . . . .. . . ,..._. m.�_.�,,.n . , . _ � +� <br /> � � I �j - - - - - � UNIT COOLER (BEVERAGE COOLER)(087): ROUTE T' IW TO <br /> ; � � � �u FLOOR SINK. PROVIDE HEAT TRACE FOR ALL PIPING IN THE <br /> �;�� � ���- � �I���`�� � ��� �� I i COOLER. <br /> 23 �s�a. � II , � � _ � <br /> � UNIT COOLER (COOLER) (089): ROUTE 1" IW TO FLOOR SINK. �. <br /> ; I � �i I � 2"V � � �����II FD-1 , � ����� �� � i PROVIDE HEAT TRACE FOR ALL PIPING IN THE COOLER. <br /> I 26 P-19 �� - - ' �� <br /> � UNIT COOLER (FREEZER) (095): ROUTE 1 IW TO FLOOR SINK. <br /> 30 �•-�i -II� � � �� ��_-; 2 �� ����� PROVIDE HEAT TRACE FOR ALL PIPING IN THE FREEZER. <br /> �I � 1�! II I� _ � i i <br /> 5 EXHAUST HOOD WITH MAKE-UP AIR (107) : ROUTE 1" HW FROM <br /> � � � � � � . <br /> � ii � �, ����r���, � � <br /> __ � � <br /> q � I �� � � ` � �'�� � � � � ITEM 133 TO WASH SOLENOID ASSEMBLY PROVIDED BY � <br /> �� `.� � ���`�` � `�`����``� ����;, / � KITCHEN CONTRACTOR, MOUNTED BY PLUBMING <br /> 4"SAN �' ' -' 1 � ��N J 314"HW � N � � i ,_ CONTRACTOR. ROUTE 2" lW TO FLOOR SINK. <br /> �� e ' ' d� -"� � % 3!4"PCW �� �������� � MOBILE CONVECTION OVEN (DOUBLE) (108): 3/4 G. INSTALL <br /> � ��� <br /> � . : �-� <br /> g � J � � - {�� � r 219��' � QUICK DISCONNECT SUPPLIED BY FOOD SERVICE CONTRACTOR. <br /> 32 � � � �:�� � <br /> 1 � ' N �����,� ��� , r - ' - , � <br /> ��i (I p � _ � �� � MOBILE COMBI OVEN (DOUBLE STACKED) (109): TWO OVENS <br /> � ,� � I- STACKED ON TOP OF EACH OTHER. FOR EACH OVEN PROVIDE <br /> 26 P-3A ���-��- , � �� � <br /> � I i� 1 i <br /> � — �' � II - � � � � `�.. 3/4" G, 3/4" CW,AND 3/4" CW FROM ITEM 113 WATER FILTER. <br /> � � - �' � � <br /> �; � �--� � / � p ���x�� � � ROUTE 1-1/2" IW FROM EACH OVEN TO FLOOR SINK. INSTALL <br /> 31 q P 1A � l 2 � �. I ' QUICK DISCONNECTS FOR GAS AND WATER SUPPLIED BY FOOD <br /> I � <br /> � `� II / I 1 � � <br /> I -� I � SERVICE CONTRACTOR. <br /> ��I � _ r 1 1/4"PCW_ � � -, 1 1/2"PCW <br /> ��I � FLOOR TROUGH AND GRATE (112): 3" GREASE WASTE. ` <br /> '�' �� .a �' _ , " � , _ �,, " i <br /> \ \.\ .� 1 \_ . '��' '� _\ � II I . <br /> 32� �'� � _ � -�—�- -- _ - � � <br />� 5 I � 1 1/4"PCW-- r �I �) _�� i <br /> � WATER FILTER (113): TWO WATER FILTERS. 1/2"CW TO <br /> P-1A '', I I I i, il _ I l/` � EACH. ROUTE EACH 1/2" CW TO ITEM 109 AFTER PASSING <br /> THROUGH FILTER. <br /> �: - I <br /> ,� � ��I N ^ '� 1 � I 1 1/2"PCW I I i ,I i ! <br /> I � , <br /> 10 (2) BURNER RANGE (114): 3/4 G. INSTAL.L QUICK DISCONNECT <br /> 4 SAN � � �� �_ ���1��� ���� u i H � � � i � <br />� 26 P-3A � � - �� I�_ .!�_i���i� I i SUPPLIED BY FOOD SERVICE CONTRACTOR. <br /> �� � �� '� � 'I � ��-�j1 1l2"HW 11 � -_� �, . . <br /> � �, �3�� J314"HW� � � � �� �I n % _ � � <br /> : I � 11 BRAISING PAN 30 GAL) (115). 3/4 G. INSTALL QUICK <br /> � N -1 1/4 HW �� ° 3/4"HWC \, �: '' �� ���j� � �°���~� � ,. - ��� �Y. � DISCONNECT SUPPLIED BY FOOD SERVICE CONTRACTOR. <br /> - � - �I � _ . - - - - _ - <br /> I I ( - � [ �- �-� --� �' 12 FILL FAUCET 116 1/2" CW AND 1/2" HW. :' <br /> . . ��I (� '.,/_ >> . . ��� ���J ..� J � ��J �- i > J —__— � <br /> � � ��Y� � � � �� <br /> � _ __�1.. _ �u ��� �, � , ;� a � �� � <br /> - , � � , � � i <br /> _ ,� � « <br /> 32 � �... o�..�.���, � � _. � ��, . ` : �"�'�'�: _ � _ � �=..v_ ,�..: � . �� �� � i �, I,i � � � ' ' �. 13 HAND SINK WITH ELECTRONIC FAUCET(040): 1/2" CW, 1/2° � <br /> _ <br /> __ � <br /> ���� � , . � � , ; � � <br /> � � � ,:, , , ,�; u� ��t�t�;� �� �� � � � I � �I � � \� �� � HW, 1-1/2"W, AND 1-1/2 V. INSULATE STOP, SUPPLIES, AND <br /> �"� Zg � � ��'I�� i 27 �� u =__ � ' �� � �I.. I � �. � � � �\� � F TURE MOUNTED�BELOW SINKMIXING VALVE FOR . <br /> ?. '��� � ��' 3�4°HWCi � � .��. a-°3� ��—-`���,• --`����—_`a�v---°a v---�a �—--—----�'-- '� . <br /> ���:�� - — — — — <br /> � „ ;�� 14 WORKTABLE WITH PREP SINKS (118): STUB UP 1/2"CW � <br /> 2 ( �'��� � �,�,,,'�� 25 �� H � .,�- � i- � <br /> '� � 3-, � (� - `�� � �� �� � ii _ n � <br /> � � AND 1/2 HW FROM BELOW. ROUTE 1 1/2 IW(X2)TO FLOOR <br />� ��' � (� I �� �� �� �� � SINK. <br /> r <br /> I <br /> �J I � I�_-�-�__� � � FD-2 � (I � V� i � 15 WORKTABLE WITH PREP SINKS (139): 1/2"CW AND 1/2° HW. <br /> II .�._. .� <br /> �, , -, II „ ii � �;w �� : � ROUTE 1-1/2 IW TO FLOOR SINK. <br /> �:�� a, � � u ���' ������� � <br /> � � I ( (; n u 3/4 PCW �� <br /> �= �= � � � �; �� u � ���.;-- ��.,_ ��I �-�;- �. -- � 16 SOILED DISHTABLE (143): 1/2"CW AND 1/2" HW. ROUTE 1-1l2° <br />� ' � ' / � � �-� � ��� ,� � �� ���c� � ——r- � � <br /> �� 3�� � I I (�i II (I II ' ` � �� ,_ �I � IW XZ TO FLOOR SWK. <br /> i .->��_^ � �� ---� ( ) <br /> _: � , � � r-- � -�' !._ � � — , --_� <br /> __ -----_--_ _----�,._.---------. �__�.��.=___�, „ <br /> , � ; � -� ,x��,�� T - _ - - - -- - -. --- - ---�.___, t"r �7 DISHWASHER WITH BOOSTER HEATER 146 1/2 CW AND <br /> — — - - — - —— � - - ��`�������-- - -- - — — —� - � , � � . ; , . � - - � ----- - �.��� ( )� <br /> :., � <br /> ' 3/4" HW. PROVIDE ASSE 1004 ATMOSPHER(C BACKFLOW <br /> =;�, �; °���, , � �� � � � � � �:,�- a� i-t- -.�t�----�-� -�__-__=��� I _. � . <br /> .��.; <br /> -�� i � j' j �� p ' / �'�. q i � -'� PREVENTERS AND PRESSURE REDUCING VALVES ON HW <br /> _ <br /> -� '� � AND CW LINES. ROUTE 1-1/2" IW X2 TO FLOOR SINK. <br /> � �.� II —� � � � �� � �I � � i � � _� r i � O <br /> u II � � \ <br /> � <br /> �, � <br /> _ � � PROVIDE DRAIN TAMPERING KIT. <br /> � i <br /> �2� 152 ��� II II � � (� �I � � � � � <br /> �, T�, � � ��� <br /> ,� �� -�--__ __ �� � i \ j � ;I ( � ,n � �8 POT WASHING SWKS (149): 112"CW(X2)AND 3/4" HW(X2). <br />� Z��G � � ;- � � � ( __ _=� �i� �__ ���I" -`=��� `,�-�--_°" `'-_� ____ -_�"`�' ' � � I i ROUTE 1-1/2" IW(X2)TO FLOOR SINK. <br /> � NOT USED. <br /> i ' '"�' ,I-_�,,� � ����"�.` ������� � ( 19 <br /> � � � I ' � = r � � <br /> �� / � I �' 3/4"PC� 6 �os � � u i ��.. � � � <br /> � , <br /> 1 1l2 G ( ((. r -�� F ; r� ' �� � l �-- , I - <br /> i � � D• � � i - � ' �� `'� �'' �� � � -1 _J �—r n u u <br /> _ � � � , ,. : - '«--�--�� .-------- , ,��+ i � ? � o \ .,I ! �"i��� ' i ; ' , - i � 20 EYE WASH STATION (152): 1/2 CW, 1/2 HW, 1-1/4 W,AND 1- <br /> �29' � � r�� t----=�- � I !N � � � I ; � �� , j � --� -� � � �i� 22 �ss � j � 1/4"V. INSULATE STOP, SUPPUES,AND TRAP. PROVIDE � � <br /> f � � �� ( ( - " � �� � II � � � � t \��� , % � 4 os5 I� .N , � THERMOSTATIC MIXING VALVE MOUNTED BELOW STATION. <br /> �- _� I _ � �� r -- .;�-- ,� — — - � I <br /> SET MIXING VALVE TO 105 F INITIALLY AND COORDINATE WITH <br /> �.� � � , - ���, r r � 28 ,r � <br /> � ( ( ��� (� � �� � � � ' T��' I ���� �� � \_, �`- �...� °��°��.,� °� I � , ����;��I ' , <br /> N � ���I -� � u � � ' �`�i , I OWNER FOR FINAL TEMPERATURE. <br /> 2� AND " " <br /> �21 ; - 155 II� � il / �' r� � II � ; '� <br /> , � � � � � <br /> � � � � <br /> � ,. <br /> �� I I �� � � 7 ; 109 �� ; ; � r_k .% / ~'�.. 'I.." �'e,. I�,. ��. U �—� : <br /> � i � � � �� ° � �' „ , , ; ! ; �,, *� � \: ° � ' � ✓ -� _ � .^� ' � H SWK WITH ELECTRONIC FAUCET(155): 1/2 CW, 1/2 <br /> � �) , , 314 PCW -1/ � ,�r � r� �S1 �I , -� � � � <br /> � _ I � � � ��' � � � , � ' � `� � ' -.-�°° -�-"� ` ' ' HW, 1-1/2"W, AND 1-112"V. INSULATE STOP, SUPPLIES,�AND � � <br /> _- i - _:. __ -- --- <br /> : �: _ � �"� <br /> I � <br /> - - --- --- -- - ---- ---- � <br /> „ I � , ' C> �JI!, � I �I�C� i � c! I (' I � .s�l —�.�P— 4-.,�4 � C -S—P —C P-. __t: -P - <br /> I I I � / l I� �(� � r C � " �> � > � �'`� � > � �` �� ------- � TRAP. PROVIDE THERMOSTATIC MIXING VALVE FOR FIXTURE . <br /> � � �( �. 28 , � � i `I�� �� � � � � �� � , ( ) �(- _ <br /> � <br /> ° I 3 ,� � I� � �� T' � � MOUNTED BELOW SINK. SET MIXING VALVE TO 115 F <br /> _�_I �� ,� , _ � \ � � - --fi. �� � � �' � I I� I �� , <br /> I I r � INITIALLY AND COORDINATE WITH OWNER FOR FINAL <br /> �� � "'�� i � � ' �- � �� � ,I �� i � �\ <br /> � , 1 G � <br /> � � � � _�I���, I`'�„ '� -�� I � �� �� � FD-2 t � � � ii � �� � TEMPERATURE. <br />+ � �. � � �� .ii �1 PCW �- ! --r — i � I � � I� � � � � t - � <br /> �$ � 149 ,, � � ' 9 113 ( � , , , ;� 'I �I I' I <br /> . � „� �� >�( � `T u ( j �� r� f �.\ �� 22 SODA SYSTEM (165): 1/2" CW. PROVIDE LISTED REDUCED <br /> � "�' , ' �, I � (� II � �' �`�° ' I',. I I � p � II, ", � .�� ;I c �'�� o �_ e �- . __ r�� ,; e_,; � �' � _ �� �--�,I _ _ -_-- ,-�1n ; PRESSURE PRINCIPLE BACKFLOW PREVENTER AS <br /> � <br /> (l �- ----- ,: <br /> � i ( �i _ � � � FS-� �� 114 � �= - II � a�, _ at -�-- �r� .>--�s � _ -a�o---' i ' - <br /> � � � ` <br /> ' ' i > � ��.-`!�t �-- � ; APPROVED BY AHJ AND RUN THROUGH FILTER. <br /> �:g <br />� ���'� � �� �� � .�.� � � , ;�� 11 � ��-� � � l � ' � o ' I � ����m�� � <br /> ��� � � „ �� �'���,-�-� ' 12 ��s� �- II � I'; l`�� i � 23 EXHAUST HOOD DETERGENT PUMP (167): ROUTE (3) 3/8" <br />� �,������ ( 2„� � � ' �� ��r,1 PCW�!!� ��� I I � � � �- -, �� � `� �,���-�-� � - COPPER LINES FROM DETERGENT PUMPS 167 TO EXHAUST <br /> ��� i 1� � � ;�I � ' � ��'� _ � ' � �1 ; 8 �i2 i� \ �� �� � �- -� � 3 oss i �� HOOD CONTROL CABINET 133. <br /> I�� T 24 NOT USED. <br /> ,_r__r —�. . . , � �) � �I I_'�_(-_��� � � � <br /> : I I _ , . . �. hn � ,1 1/4"PCW � � <br /> I - . '� _ �� �� �il �'� 115 2"�/�I� <br /> �� �''� � � ' � I I � ��= �I � �� -� �` -,� �,�`\ �° �``�� v'I� �., �� �,�� <br /> I � . * =� <br /> ,� <br /> `�� � FD-2 ' � 1 1l4"PCW - ��� � � � ��_ /` � I .�' � � ;���� <br /> _ ° / I � (3) 3/8 COPPER LINES FROM DETERGENT PUMPS 167 TO <br /> ���� �� � � �� ��0 � II� �,� �� , � � <br /> �' „ � - � � <br /> � <br /> � _�� / \ \\ � �� <br /> 17 146 � I � i�;I II� _ TII� I^� �_ � � ^->'i ` �c°_ Z?. o' l�•��o> ,,.� `� �� � 2�J <br /> � � <br /> I rI _ �_ , _ ,��—�s t—TJ , II 1 1�"�.,° . -- <br /> � <br /> ��� ��'' �t� _r��' ' ' - .-- -�-----� I I� � ' ""� � � -- -�-- '- - , ,>, EXHAUST HOOD CONTROL CABINET 133. <br /> I i � �y � ���- 26 PROVIDE THERMOSTATIC MIXING VALVE. SET MIXING VALVE TO <br /> �-_..,���t � FS-1 � 11 �� � ��� -- �$ �� �o,= --- � � � /',- �I� ��(��,.,� � ;Iv -,,� 4 � � ' <br /> � � � � � � q � �. <br /> , , � ' � � I I� --- 3/4"HWC; � / ��, �i � ��.� „I � �.� � 115 F INITIALLY AND COORDINATE WITH OWNER FOR FINAL <br /> � M� � <br />� � � � �i I FS-1 N . .ii � � r��,; 5 �o� � .� �_� � �_--�!��- �=��— -�` --- � . <br /> �.'��j��' _Jj � — I I = _. .�L. �� � I� �``�� -1 � TEMPERATURE <br /> �_I. . . . 1 1/2 HW _ ' , � � �� <br /> -;�,R�,��i � —�•�,�-�• • 28 /,: `_ I � 2 os� 27 3/4 HWC BALANCING VALVE. SET AT 1 GPM. <br /> ( ._�� =� <br /> ��i �i� ( p 13 117�� '`14 ��8 � � �.!1 ��� ������ � � �. 2g 2��V DN. <br /> I � ., O <br /> 16 �a3 � 1 /4 � <br /> �� � � � � 1 HW � �� � - � � � --, ( <br /> 29 GAS SOLENOID VALVE. SHUT OFF GAS FLOW WHEN ANSUL <br /> „ � � 2'I��2 <br /> � a �� �� �1 1 1l2 PCW ��,�.• ��� �,�-''� � _j ; i �: . FIRE SUPPRESSION SYSTEM IS ACTIVATED. <br /> � � � � u �-1 114 NW �� _ - - -_' - - - - --� - -- -- i ��� <br /> � ( b I �� FS-� -��1 rT i r-f I ?T I i7 i iT I ?�T I T-T I �T ! TT I ��; l�I �f 1 T-T I 1—(� � � i <br /> �- i I t ( r I � 1 H W — _- � � � ; �� i { 3 0 R O U T E 4" S A N A B O V E F L O O R A N D I N 6" S T U D W A L L T O <br /> i f �� �� � �li ! i I I I i ' I I i i I I I � I I I i I ; I �I � I j I � I ! ��I ! I I ( I f i I i ! I �- ' il�� � � AVOID BEAM BELOW PLUMBING FIXTURES. � � � <br /> 15�� � �ss � � �� �r ��: ,�� �� �;I I I I I i I � i (� i i i i i '�i i I I I I ! I i I i I ! i ( ��I I I I I I I I i I I i ! i i � '� 31 4"SAN DN. � <br /> � n \� _ , � <br /> � �J— — , � i , �� � �_;-�' � � - �,-� t- � r�-' t ' � <br /> / � `� 3 V -�r�;=r�� (�r�t��� r�l�� i 1-r�� r-��=I;` , <br /> ��, n� � ` � <br /> �� � .:� <br /> � —�- � I � _ 32 OFFSET VENT AROUND BEAM. <br /> �..�..•=� � ��I � � � � ��� �� � , / �� � ��' �� � �, _,� <br /> �---� �" - ' - �� �- - - - --- - -- - ---- - - -- -- -1 � ,� 1 <br />� ----- - -- �, � I <br /> 28 �� � ;:kt ---=A-d II \ __ � ---- -- - ------ - - -- - - - -- - ' - - - ------ \ � <br /> "� - - � i �, _. <br /> � �� �; i I � 4�== -`� � I <br /> �i i ; ,� ; � II N I) 2�,2��� \ ; CONSTRUCTION NOTES <br /> � � , � „ �� � � <br /> �� ' � i �i I I I � �I I F D-2 11..___z��� I <br /> � FS-1 <br /> ' - ! � REFERENCE DRAWINGS <br /> i ; , <br /> ; � � Tenant Improvements (TI) ' <br /> HARGIS K• �lj <br /> Hargis Engineers, Inc. O � O <br /> 1201 Third Avenue, Suite 600 � Seattle, WA 98101 <br /> EN LARGED KITCH EN PLAN � WEST � t� 206.448.3376 f� 206.448.4450 w� hargis.biz � <br /> 900 SW 16th Street Suite 307 � �11 � <br /> SCALE: 1/4��_ ��-Q�� 2M110-32 M474 ENGINEERS�MECHANICAL•ELECTRICAL•TELECOMMUNICATIONS O 2� 4� 8� �2� <br /> Renton, Washington 98057 �NAL �� <br /> �rz��1� SCALE: 1/4" = 1'-0" Q <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE wqs ACCEPTABILITY DRAWN DATE SUBTITLE CURRENTREVISION SYMBOL DATE � • <br /> � oe y,Nc AJH 01J26/16 ENLARGED PLUMBING PLANS - LEVEL 2 W2548317 2 01/26/16 � <br /> 0 REVISION-RELEASE 18(IFC TI) AJH RKE 05/19115 �. r THIS DESIGN AND/OR cNECKE� <br /> � y SPECIFICATION IS APPROVED RKE 01126/16 SHEET r <br /> 1 Revision Release 32(TI) AJH RKE 12/01/15 � eRPH�cH�TecTs �N�w�ER TVTLE Boein 777X CWC BUILDING o <br /> ���,�� ENGiNEERSiNC. APPROVED BY DEPT. DATE RKE 01/26/16 g � <br /> 2 REVISION-RELEASE 35(TI) AJH RKE 01/26116 r,o.a�si cHECKE� M 4 7L� N <br /> � BUILDING 40-58 <br /> m�'� o APPROVED � <br /> JOB NO. COMP NO. _ <br /> �'•� �tiP� A rover 40-58-M474 -� <br /> 9rF oF aujNo�` APPRovE� MECHANICAL MASTER 2.0-2.7/E-E.50 EVERETT, WA owc No. 40-5$-M474 ¢ <br />